Product Overview
The RTY Series and RTP Series Hall-effect Rotary Position Sensors offer non-contact sensing for demanding transportation and industrial applications at a competitive price. The RTY Series features an integral shaft with or without a lever, while the RTP Series separates the magnet from the sensor body for enhanced durability. Both series utilize Hall-effect technology to convert rotary movement into a linear output, housed in a rugged, IP69K-qualified package. They offer a wide range of operating angles and input voltage options, backed by Honeywell's quality and support.
Product Attributes
- Brand: Honeywell
- Certifications: CE, UKCA
- Material: Stainless steel (shaft, bushing), PBT plastic (sensor housing, housed magnet overmold), NdFeB (magnet), PPS plastic (housed magnet)
- Protection: IP69K-qualified, automotive-grade EMI/EMC, integrated reverse polarity, and short circuit protection
- Termination: Industry-standard AMP
Technical Specifications
| Characteristic | RTY Series (LV/HV) | RTP Series (LV/HV) |
| Expected life | 35 M cycles | Infinite rotation |
| Air gap (housed magnet actuator) | 2.00 mm 0.5 mm [0.08 in 0.02 in] | |
| Air gap (bare magnet actuator) | 3,00 mm 0.5 mm [0.12 in 0.02 in] | |
| Supply voltage | 5 0.5 Vdc (LV) / 10 Vdc to 30 Vdc (HV) | 5 0.5 Vdc (LV) / 10 Vdc to 30 Vdc (HV) |
| Supply current (max) | 20-25 mA (LV) / 32-47 mA (HV) | 20-25 mA (LV) / 32-47 mA (HV) |
| Output signal | 0.5 Vdc to 4.5 Vdc ratiometric or non-ratiometric (standard/inverted) | 0.5 Vdc to 4.5 Vdc ratiometric or non-ratiometric (standard/inverted) |
| Output signal delay | 4 ms typ. | 4 ms typ. |
| Overvoltage protection | 10 Vdc (LV) / (HV) | 10 Vdc (LV) / (HV) |
| Reverse polarity protection | -10 Vdc (LV) / -30 Vdc (HV) | -10 Vdc (LV) / -30 Vdc (HV) |
| Output to ground short circuit protection | Continuous | Continuous |
| Resolution | 12 bit | 12 bit |
| Output load resistance | 10 kOhm typ. | 10 kOhm typ. |
| EMI radiated immunity | 100 V/m per ISO11452-2 (200 MHz to 1000 MHz) | 100 V/m per ISO11452-2 (200 MHz to 1000 MHz) |
| EMI conducted immunity | 100 mA BCI per ISO11452-4 (1 MHz to 200 MHz) | 100 mA BCI per ISO11452-4 (1 MHz to 400 MHz) |
| Operating temperature range | -40 C to 125 C [-40 F to 257 F] | -40 C to 125 C [-40 F to 257 F] |
| Ingress protection | IP69K | IP69K |
| Media compatibility | Heavy transportation fluids | Heavy transportation fluids |
| Shock | 50 G peak (excluding RTY sensor shaft with lever) | |
| Vibration | 20 G peak (excluding RTY sensor shaft with lever) | |
| Salt fog | 5% 1% for 240 hr per SAE J1455 (LV) / 96-240 hr per ASTM B117 (HV) | 5% 1% for 240 hr per SAE J1455 (LV) / 96-240 hr per ASTM B117 (HV) |
2412201833_Honeywell-RTY050LVNBA_C17431657.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible