Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Rotary position sensor Honeywell RTP270HVNBY with PPS plastic housed magnet and stainless steel shaft factory
<
quality Rotary position sensor Honeywell RTP270HVNBY with PPS plastic housed magnet and stainless steel shaft factory
>
Specifications
Mfr. Part #:
RTP270HVNBY
Key Attributes
Model Number: RTP270HVNBY
Product Description

Product Overview

The RTY Series and RTP Series Hall-effect Rotary Position Sensors offer non-contact sensing for demanding transportation and industrial environments at a competitive price. The RTY Series features an integral shaft with or without a lever, while the RTP Series separates the magnet from the sensor body, eliminating bearing wear from radial forces. Both series utilize a Hall-effect IC to convert rotary actuator movement into a linear output, housed in a rugged, IP69K-qualified package with extensive environmental and electrical protection. They support eight operating ranges from 50 to 360 and a wide input voltage range (4.5 Vdc to 30 Vdc).

Product Attributes

  • Brand: Honeywell
  • Certifications: CE
  • Material (Shaft): Stainless steel (RTY Series)
  • Material (Magnet): NdFeB
  • Material (Sensor Housing): PBT plastic
  • Material (Housed Magnet): PPS plastic
  • Material (Bushing): Brass
  • Mating Connector: AMP Superseal 282087-1

Technical Specifications

CharacteristicRTY Series (LV/HV)RTP Series (LV/HV)
Expected Life35 M cyclesInfinite rotation
Air Gap (bare magnet actuator)-3.00 mm 0.5 mm [0.12 in 0.02 in]
Air Gap (housed magnet actuator)-2.00 mm 0.5 mm [0.08 in 0.02 in]
Misalignment (housed magnet actuator)-2.00 mm [0.08 in] max.
Supply Voltage5 0.5 Vdc (LV)
10 Vdc to 30 Vdc (HV)
5 0.5 Vdc (LV)
10 Vdc to 30 Vdc (HV)
Supply Current (normal)20 mA max. (LV)
25 mA max. (HV)
32 mA max. (LV)
47 mA max. (HV)
Supply Current (output to ground short)20 mA max. (LV)
25 mA max. (HV)
32 mA max. (LV)
47 mA max. (HV)
Output Signal Delay4 ms typ.4 ms typ.
Overvoltage Protection10 Vdc (LV)
- (HV)
10 Vdc (LV)
- (HV)
Reverse Polarity Protection-10 Vdc (LV)
-30 Vdc (HV)
-10 Vdc (LV)
-30 Vdc (HV)
Output to Ground Short Circuit Protectioncontinuouscontinuous
Resolution12 bit12 bit
Output Load Resistance (pull down to ground)10 kOhm typ.10 kOhm typ.
EMI Radiated Immunity100 V/m per ISO11452-2 (200 MHz - 1000 MHz)100 V/m per ISO11452-2 (200 MHz - 1000 MHz)
EMI Conducted Immunity100 mA BCI per ISO11452-4 (1 MHz - 200 MHz)100 mA BCI per ISO11452-4 (1 MHz - 400 MHz)
Operating Temperature Range-40 C to 125 C [-40 F to 257 F]-40 C to 125 C [-40 F to 257 F]
Ingress ProtectionIP69KIP69K
Media CompatibilityHeavy transportation fluidsHeavy transportation fluids
Shock50 G peak (excluding RTY sensor shaft with lever)20 G peak
Vibration20 G peak20 G peak
Salt Fog Concentration5% 1% for 240 hr per SAE J1455 (at 5.0 Vdc, 38 C [100 F])Bare magnet: 96 hr per ASTM B117
Housed magnet: 240 hr per ASTM B117

2411271802_Honeywell-RTP270HVNBY_C17678384.pdf