Honeywell HPM Series Particulate Matter Sensor
The Honeywell HPM Series Particulate Matter Sensor is a laser-based sensor designed to detect and count particles using light scattering. It offers a concentration range of 0 g/m to 1,000 g/m and provides real-time monitoring and control of environmental particulates. Key advantages include industry-leading long life of 10 years, proven EMC performance for stable operation in industrial environments, and a fast response time of less than 6 seconds. Potential applications include HVAC systems, indoor and handheld air quality monitors, and automotive cabin air purifiers.
Product Attributes
- Brand: Honeywell
- Certifications: RoHS compliant, REACH compliant, IEC61000 (EMC), IEC/EN 60825-1 (Laser Class 1)
Technical Specifications
| Characteristic | Standard | Compact |
| Operating principle | laser scattering | laser scattering |
| Detection | PM2.5, PM10 | PM1.0, PM2.5, PM4.0, PM10 |
| Output data | PM2.5 in g/m, PM10 in g/m | PM1.0 in g/m, PM2.5 in g/m, PM4.0 in g/m, PM10 in g/m |
| Concentration range | 0 g/m to 1,000 g/m | 0 g/m to 1,000 g/m |
| Accuracy (at 25C 5C) | PM2.5: 15 g/m (0-100 g/m); 15 % (100-1000 g/m) | PM2.5: 15 g/m; PM1.0, PM4.0, PM10: 25 g/m |
| Response time | <6 s | <6 s |
| Supply voltage | 5 V 0.2 V | 5 V 0.2 V |
| Standby current (at 25C 5C) | <20 mA | <20 mA |
| Supply current (at 25C 5C) | <80 mA | <80 mA |
| Temperature: operating | -20C to 50C [-4F to 122F] | -20C to 70C [-4F to 158F] |
| Temperature: storage | -30C to 65C [-22F to 149F] | -40C to 85C [-40F to 185F] |
| Humidity (operating and storage) | 0 %RH to 95 %RH non-condensing | 0 %RH to 95 %RH non-condensing |
| Output protocol | UART; baud rate: 9600, databits: 8, stopbits: 1, parity: no | UART; baud rate: 9600, databits: 8, stopbits: 1, parity: no |
| Operating time: continuous mode | 10 years | 10 years |
| Laser class | Laser Class 1: IEC/EN 60825-1: 650 nm | Laser Class 1: IEC/EN 60825-1: 650 nm |
| ESD | 4 kV contact, 8 kV air per IEC 61000-4-2 | 4 kV contact, 8 kV air per IEC 61000-4-2 |
| Radiated immunity | 1 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 | 1 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 |
| Fast transient burst | 0.5 kV per IEC61000-4-4 | 0.5 kV per IEC61000-4-4 |
| Immunity to conducted disturbances | 3 V per IEC61000-4-6 | 3 V per IEC61000-4-6 |
| Radiated emissions | 40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 14 | 40 dB 30 MHz to 230 MHz; 47 dB 230 MHz to 1000 MHz per CISPR 14 |
| Conducted emissions | 0.15 MHz to 30 MHz in compliance with CISPR 14 | 0.15 MHz to 30 MHz in compliance with CISPR 14 |
| Dimensions (L X W X H) | 43 mm x 36.00 mm x 23.7 mm [1.69 in x 1.42 in x 0.93 in] | 44 mm x 36 mm x 12 mm [1.73 in x 1.42 in x 0.48 in] |