Product Overview
The RTY Series and RTP Series Hall-effect Rotary Position Sensors offer non-contact sensing for demanding transportation and industrial environments at a competitive price. The RTY Series features an integral shaft with or without a lever, while the RTP Series separates the magnet from the sensor body for enhanced durability. Both series utilize Hall-effect technology to convert rotary movement into a linear output, sealed in a rugged, IP69K-qualified package. They offer multiple operating ranges and voltage options, backed by Honeywell's industry-leading support.
Product Attributes
- Brand: Honeywell
- Certifications: CE, UKCA
Technical Specifications
| Characteristic | RTY Series LV | RTY Series HV | RTP Series LV | RTP Series HV |
| Expected life | 35 M cycles | 35 M cycles | Infinite rotation | Infinite rotation |
| Supply voltage | 5 ±0.5 Vdc | 10 Vdc to 30 Vdc | 5 ±0.5 Vdc | 10 Vdc to 30 Vdc |
| Supply current (normal) | 20 mA max. | 25 mA max. | 32 mA max. | 47 mA max. |
| Output: standard | 0.5 Vdc to 4.5 Vdc ratiometric | 0.5 Vdc to 4.5 Vdc non-ratiometric | 0.5 Vdc to 4.5 Vdc ratiometric | 0.5 Vdc to 4.5 Vdc non-ratiometric |
| Output: inverted | 4.5 Vdc to 0.5 Vdc ratiometric | 4.5 Vdc to 0.5 Vdc non-ratiometric | 4.5 Vdc to 0.5 Vdc ratiometric | 4.5 Vdc to 0.5 Vdc non-ratiometric |
| Output signal delay | 4 ms typ. | 4 ms typ. | 4 ms typ. | 4 ms typ. |
| Overvoltage protection | 10 Vdc | - | 10 Vdc | - |
| Reverse polarity protection | -10 Vdc | -30 Vdc | -10 Vdc | -30 Vdc |
| Output to ground short circuit protection | continuous | continuous | continuous | continuous |
| Resolution | 12 bit | 12 bit | 12 bit | 12 bit |
| Output load resistance (pull down to ground) | 10 kOhm typ. | 10 kOhm typ. | 10 kOhm typ. | 10 kOhm typ. |
| EMI: radiated immunity | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz |
| EMI: conducted immunity | 100 mA BCI per ISO11452-4 from 1 MHz to 200 MHz | 100 mA BCI per ISO11452-4 from 1 MHz to 400 MHz | 100 mA BCI per ISO11452-4 from 1 MHz to 200 MHz | 100 mA BCI per ISO11452-4 from 1 MHz to 400 MHz |
| Operating temperature range | -40 °C to 125 °C [-40 °F to 257 °F] | -40 °C to 125 °C [-40 °F to 257 °F] | -40 °C to 125 °C [-40 °F to 257 °F] | -40 °C to 125 °C [-40 °F to 257 °F] |
| Ingress protection | IP69K | IP69K | IP69K | IP69K |
| Shock | 50 G peak | 50 G peak | 50 G peak | 50 G peak |
| Vibration | 20 G peak | 20 G peak | 20 G peak | 20 G peak |
| Salt fog concentration | 5% ±1% for 240 hr per SAE J1455 (at 5.0 Vdc, 38 °C [100 F °]) | 5% ±1% for 240 hr per SAE J1455 (at 5.0 Vdc, 38 °C [100 F °]) | bare magnet: 96 hr per ASTM B117; housed magnet: 240 hr per ASTM B117 | bare magnet: 96 hr per ASTM B117; housed magnet: 240 hr per ASTM B117 |
| Material: shaft | stainless steel | stainless steel | non-magnetic, stainless steel | non-magnetic, stainless steel |
| Material: magnet | - | - | NdFeB | NdFeB |
| Material: sensor housing | PBT plastic | PBT plastic | PBT plastic | PBT plastic |
| Material: housed magnet overmold | - | - | PPS plastic | PPS plastic |
| Material: sensor/housed magnet bushing | brass | brass | brass | brass |
| Mating connector | AMP Superseal 282087-1 | AMP Superseal 282087-1 | AMP Superseal 282087-1 | AMP Superseal 282087-1 |
| Mounting screw sizes: sensor to mounting surface | M5 screws and 10 mm [0.39 in] OD washers | M5 screws and 10 mm [0.39 in] OD washers | M4 X 0.7 screws and 8 mm [0.31 in] OD washers | M4 X 0.7 screws and 8 mm [0.31 in] OD washers |
| Mounting screw sizes: lever to mounting surface | M6 screws | M6 screws | - | - |
| Mounting screw sizes: housed magnet actuator to actuator mounting | - | - | M3 X 0.5 plain cup point set screws | M3 X 0.5 plain cup point set screws |