Honeywell Sensing and Control Current Sensors
Honeywell Sensing and Control (S&C) offers a comprehensive line of current sensors designed to monitor alternating (ac) or direct (dc) current with superior accuracy and reduced cost. Our sensors range from digital output detectors for milliamps to linear sensors for over one thousand amps. Key advantages include thru-hole design, fast response times, output voltage isolation, minimum energy dissipation, enhanced reliability, adjustable performance, and built-in temperature compensation. These sensors are based on Hall-effect or magnetoresistive principles and are suitable for a wide array of industrial applications.
Product Attributes
- Brand: Honeywell
- Certifications: RoHS compliant, CE, UL approvals
Technical Specifications
| Series | Type | Sensed Current Range | Sensed Current Type | Output | Response Time | Accuracy | Operating Temperature | Supply Voltage |
| CSDA | Digital/Inductive | 0.5 A.t. nom., 3.5 A.t. nom. | ac or dc | Digital (TTL logic level, open collector) | 100 s | better than 0.5 % | -25 C to 85 C [-13 F to 185 F] | 6 Vdc to 16 Vdc |
| CSNX | Closed Loop | 56 A | ac, dc, impulse | Current | < 0.2 s | 0.24 % | -40 C to 85 C [-40 F to 185 F] | 4.75 Vdc to 5.25 Vdc |
| CSNA | Closed Loop | 70 A, 90 A, 100 A | ac, dc, impulse | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 13 Vdc, 15 Vdc |
| CSNF | Closed Loop | 150 A, 180 A, 200 A | ac, dc, impulse | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12 Vdc to 15 Vdc |
| CSNB | Closed Loop | 100 A | ac, dc | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 15.0 Vdc |
| CSNC | Closed Loop | 90 A | ac, dc | Current | < 1 s | 0.5 % | -25 C to 85 C [-13 F to 185 F] | 13.0 Vdc |
| CSNE | Closed Loop | 36 A, 90 A | ac, dc, impulse | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 12 Vdc to 15 Vdc |
| CSNG | Closed Loop | 180 A, 200 A | ac, dc | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 15.0 Vdc |
| CSNJ | Closed Loop | 600 A | ac, dc, impulse | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNK | Closed Loop | 1200 A | ac, dc, impulse | Current | < 1 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 15 Vdc to 18 Vdc |
| CSNL | Closed Loop | 600 A | ac, dc | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNM | Closed Loop | 1000 A | ac, dc | Current | < 1 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNP | Closed Loop | 90 A | ac, dc | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSNS | Closed Loop | 320 A, 600 A | ac, dc, impulse | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12 Vdc to 18 Vdc |
| CSNR | Closed Loop | 200 A | ac, dc | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSNT | Closed Loop | 150 A | ac, dc | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSLS | Open Loop | 60 A | ac, dc | Sink/Source | 3 s | 15 mV/AT 2 mV/AT @ 5 Vdc | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLT | Open Loop | 100 A | ac, dc | Sink/Source | 3 s | 15 mV/AT 2 mV/AT @ 5 Vdc | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLW | Open Loop | 1 A, 5 A, 40 mA, 200 mA | ac, dc | Sink/Source | 3 s | Various | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSCA-A | Open Loop | 150 A, 300 A | ac, dc, impulse | Voltage | 3 s to 7 s | - | -10 C to 80 C [14 F to 176 F] | 15 Vdc 5 % |
| CSLA | Open Loop | 600 A, 900 A | ac, dc | Voltage | 3 s, 8 s | Various | -25 C to 85 C [-13 F to 185 F] | 8 Vdc to 16 Vdc |
| CSLH | Open Loop | 57 A to 950 A, 9 A, 45 A | ac, dc | Sink/Source | 3 s | 18.5 mV N* 3.5 mV N* @ 5 Vdc or 282 mV N* -42, +82 mV N* @ 10 Vdc | -25 C to 85 C [-13 F to 185 F] | 6 Vdc to 12 Vdc, 4.5 Vdc to 10.5 Vdc |
2410311240_Honeywell-CSNF661_C5629990.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible