Specifications
Mfr. Part #:
CSNR161-004
Key Attributes
Model Number: CSNR161-004
Product Description

Honeywell Sensing and Control Current Sensors

Honeywell Sensing and Control (S&C) provides a comprehensive range of current sensors for monitoring AC and DC currents, from low milliamp detection to over one thousand amps. These sensors offer superior accuracy, often at a reduced cost, backed by decades of engineering expertise. Key advantages include thru-hole design, fast response times, output voltage isolation, minimum energy dissipation, and enhanced reliability with adjustable performance and built-in temperature compensation.

Product Attributes

  • Brand: Honeywell
  • Certifications: RoHS compliant, CE, UL approvals

Technical Specifications

SeriesTypeSensed Current RangeSensed Current TypeOutputResponse TimeAccuracyOperating TemperatureSupply Voltage
CSDADigital/Inductive0.5 A.t. nom., 3.5 A.t. nom.ac or dcDigital (TTL logic level, open collector)100 sbetter than 0.5 %-25 C to 85 C [-13 F to 185 F]6 Vdc to 16 Vdc
CSNXClosed Loop56 Aac, dc, impulseCurrent< 0.2 s0.24 %-40 C to 85 C [-40 F to 185 F]4.75 Vdc to 5.25 Vdc
CSNAClosed Loop70 A, 90 A, 100 Aac, dc, impulseCurrent< 1 s0.5 %0 C to 70 C [32 F to 158 F]13 Vdc, 15 Vdc
CSNFClosed Loop150 A, 180 A, 200 Aac, dc, impulseCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12 Vdc to 15 Vdc
CSNBClosed Loop100 Aac, dcCurrent< 1 s0.5 %0 C to 70 C [32 F to 158 F]15.0 Vdc
CSNCClosed Loop90 Aac, dcCurrent< 1 s0.5 %-25 C to 85 C [-13 F to 185 F]13.0 Vdc
CSNEClosed Loop36 A, 90 Aac, dc, impulseCurrent< 1 s0.5 %0 C to 70 C [32 F to 158 F]12 Vdc to 15 Vdc
CSNGClosed Loop180 A, 200 Aac, dcCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]15.0 Vdc
CSNJClosed Loop600 Aac, dc, impulseCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12.0 Vdc to 18.0 Vdc
CSNKClosed Loop1200 Aac, dc, impulseCurrent< 1 s0.5 %-40 C to 85 C [-40 F to 185 F]15 Vdc to 18 Vdc
CSNLClosed Loop600 Aac, dcCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12.0 Vdc to 18.0 Vdc
CSNMClosed Loop1000 Aac, dcCurrent< 1 s0.5 %-40 C to 85 C [-40 F to 185 F]12.0 Vdc to 18.0 Vdc
CSNPClosed Loop90 Aac, dcCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12.0 Vdc to 15.0 Vdc
CSNSClosed Loop320 A, 600 Aac, dc, impulseCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12 Vdc to 18 Vdc
CSNRClosed Loop200 Aac, dcCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12.0 Vdc to 15.0 Vdc
CSNTClosed Loop150 Aac, dcCurrent< 0.5 s0.5 %-40 C to 85 C [-40 F to 185 F]12.0 Vdc to 15.0 Vdc
CSLSOpen Loop60 Aac, dcSink/Source3 s15 mV/AT 2 mV/AT @ 5 Vdc-25 C to 100 C [-13 F to 212 F]4.5 Vdc to 10.5 Vdc
CSLTOpen Loop100 Aac, dcSink/Source3 s15 mV/AT 2 mV/AT @ 5 Vdc-25 C to 100 C [-13 F to 212 F]4.5 Vdc to 10.5 Vdc
CSLWOpen Loop1 A, 5 A, 40 mA, 200 mAac, dcSink/Source3 svarious-25 C to 100 C [-13 F to 212 F]4.5 Vdc to 10.5 Vdc
CSCA-AOpen Loop150 A, 300 Aac, dc, impulseVoltage3 s to 7 sN/A-10 C to 80 C [14 F to 176 F]15 Vdc 5 %
CSLAOpen Loop600 A, 900 Aac, dcVoltage3 s, 8 svarious-25 C to 85 C [-13 F to 185 F]8 Vdc to 16 Vdc
CSLHOpen Loop57 A to 950 Aac, dcSink/Source3 s18.5 mV N* 3.5 mV N* @ 5 Vdc or 282 mV N* -42, +82 mV N* @ 10 Vdc-25 C to 85 C [-13 F to 185 F]6 Vdc to 12 Vdc