Product Overview
The CSHV Series are open-loop Hall-effect current sensors from Honeywell, offering a robust combination of performance and reliability for current sensing applications. These non-intrusive, electrically isolated sensors are designed for primary current measurement ranges from 100 A to 1500 A DC. They are AEC-Q100 qualified, ensuring high quality and reliability, making them suitable for demanding applications like motor control in electrified vehicles, battery management systems, and industrial equipment. The series offers customization options and global technical support.
Product Attributes
- Brand: Honeywell
- Technology: Hall-effect
- Certifications: CE, UKCA, REACH, RoHS compliant
- Qualification: AEC-Q100
- Housing Material: PBT + GF30 %
Technical Specifications
| Catalog Listing | Measure Range (A) | Sensitivity (mV/A at VS = 5 V) | Offset (mV at VS = 5 V) 25C | Offset (mV at VS = 5 V) -40C to 85C | Accuracy (% at VS = 5 V) 25C | Accuracy (% at VS = 5 V) -40C to 85C | Accuracy (% at VS = 5 V) -40C to 125C | Accuracy (% at VS = 5 V) -40C to 125C |
| CSHV100A-001 | 100 | 20 | 7 mV | 25 mV | 1 % | 2 % | ||
| CSHV200A-001 | 200 | 10 | 7 mV | 15 mV | 1 % | 2 % | ||
| CSHV300A-001 | 300 | 6.667 | 7 mV | 18 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV400A-001 | 400 | 5 | 7 mV | 13 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV500A-001 | 500 | 4 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV600A-001 | 600 | 3.333 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV700A-001 | 700 | 2.857 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV800A-001 | 800 | 2.5 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV900A-001 | 900 | 2.222 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV1000A-001 | 1000 | 2 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV1100A-001 | 1100 | 1.818 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV1200A-001 | 1200 | 1.667 | 7 mV | 10 mV | 1 % | 2 % | 1 % | 2 % |
| CSHV1500A-001 | 1500 | 1.333 | 7 mV | 10 mV | 2 % | 3 % | 2 % | 3 % |
| Characteristic | Symbol | Unit | Parameter | Condition | Min. | Typ. | Max. |
| Supply voltage max. | VS max. | V | 10 | ||||
| Reverse supply voltage max. | VR max. | V | -0.3 | ||||
| Output voltage max. | VOUT max. | V | -0.3 | 10 | |||
| Output current max. | IOUT max. | mA | -10 | 10 | |||
| Ambient storage temperature | C | -40 | 125 | ||||
| Electrostatic discharge voltage | VESD | kV | 8 | ||||
| RMS voltage for AC isolation test | VDWV | kV | 50 Hz, 1 min | 2.5 | |||
| Creepage distance | dCp | mm | 4.9 | ||||
| Clearance | dCl | mm | 4.9 | ||||
| Comparative tracking index | CTI | PLC3 | |||||
| Primary current, nominal DC | IPN | A | -IPN | IPN | |||
| Supply voltage | VS | V | 4.5 | 5 | 5.5 | ||
| Output voltage (at IP = 0) | VOS | V | 2.500 | ||||
| Electrical offset voltage | VOS, ELECT | mV | TA = 25C, VS = 5 V | 3 | |||
| Magnetic offset voltage | VOS, MAG | mV | TA = 25C, VS = 5 V | 2 | |||
| Current consumption | ISUPPLY | mA | TA = 25C, VS = 5 V | 13 | |||
| Load resistance | RL | Ohm | 10k | ||||
| Output impedance | Rout | Ohm | 10 TA = 25C T = -40C to 125C | 1 | |||
| Ratiometric error | r | % | TA = 25C | 0.5 | |||
| Sensitivity error: 100 A to 1200 A | g | % | TA = 25C, VS = 5 V | 0.6 | |||
| Sensitivity error: 1500 A | g | % | TA = 25C, VS = 5 V | 0.8 | |||
| Linearity error | L | % | % of full scale output | -1 | 1 | ||
| Ambient operating temperature | C | -40 | 125 | ||||
| Average temperature coefficient VOS, ELECT | mV/C | 0.04 | |||||
| Average temperature coefficient of G | %/C | 0.02 | |||||
| Step response time (10 % to 90 %) | tr | s | 2 | 6 | |||
| Frequency bandwidth | BW | kHz | -3 dB | 45 | |||
| Output RMS noise (RMS) | mV | 2 |