Honeywell Sensing and Control Current Sensors
Honeywell Sensing and Control (S&C) offers a comprehensive line of current sensors for monitoring alternating (ac) or direct (dc) current. These sensors provide superior, accurate performance at a reduced cost, leveraging decades of engineering expertise. Key advantages include thru-hole design, fast response times, output voltage isolation from input, minimum energy dissipation, and enhanced reliability with adjustable performance and built-in temperature compensation. They are suitable for a wide range of applications, including variable speed drives, overcurrent protection, ground fault detectors, current feedback control systems, robotics, UPS and telecommunication power supplies, welding power supplies, battery management systems, and wattmeters.
Product Attributes
- Brand: Honeywell Sensing and Control (S&C)
- Certifications: RoHS compliant, CE, UL approvals
Technical Specifications
| Series | Sensed Current Type | Sensed Current Range | Output | Response Time | Accuracy | Operating Temperature | Supply Voltage |
| CSDA | ac or dc | 0.5 A.t. nom., 3.5 A.t. nom. | Digital (TTL logic level, open collector) | 100 s | better than 0.5 % | -25 C to 85 C [-13 F to 185 F] | 6 Vdc to 16 Vdc |
| CSNX | ac, dc, impulse | 56 A | Current | < 0.2 s | 0.24 % | -40 C to 85 C [-40 F to 185 F] | 4.75 Vdc to 5.25 Vdc |
| CSNA | ac, dc, impulse | 70 A, 90 A, 100 A | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 13 Vdc, 15 Vdc |
| CSNF | ac, dc, impulse | 150 A, 180 A, 200 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12 Vdc to 15 Vdc |
| CSNB | ac, dc | 100 A | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 15.0 Vdc |
| CSNC | ac, dc | 90 A | Current | < 1 s | 0.5 % | -25 C to 85 C [-13 F to 185 F] | 13.0 Vdc |
| CSNE | ac, dc, impulse | 36 A, 90 A | Current | < 1 s | 0.5 % | 0 C to 70 C [32 F to 158 F] | 12 Vdc to 15 Vdc |
| CSNG | ac, dc | 180 A, 200 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 15.0 Vdc |
| CSNJ | ac, dc, impulse | 600 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNK | ac, dc, impulse | 1200 A | Current | < 1 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 15 Vdc to 18 Vdc |
| CSNL | ac, dc | 600 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNM | ac, dc | 1000 A | Current | < 1 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 18.0 Vdc |
| CSNP | ac, dc | 90 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSNS | ac, dc, impulse | 320 A, 600 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12 Vdc to 18 Vdc |
| CSNR | ac, dc | 200 A | Current | < 0.5 s | 0.5 % | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSNT | ac, dc | 150 A | Current | < 0.5 s | < 0.5 s | -40 C to 85 C [-40 F to 185 F] | 12.0 Vdc to 15.0 Vdc |
| CSCA-A | ac, dc, impulse | 150 A, 300 A | Voltage | 3 s to 7 s | N/A | -10 C to 80 C [14 F to 176 F] | 15 Vdc 5 % |
| CSLS | ac, dc | 60 A | Sink/Source | 3 s | N/A | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLT | ac, dc | 100 A | Sink/Source | 3 s | N/A | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLW | ac, dc | 1 A, 5 A, 40 mA, 200 mA | Sink/Source | 3 s | N/A | -25 C to 100 C [-13 F to 212 F] | 4.5 Vdc to 10.5 Vdc |
| CSLA | ac, dc | 600 A, 900 A | Voltage, Sink/Source | 3 s, 8 s | N/A | -25 C to 85 C [-13 F to 185 F] | 8 Vdc to 16 Vdc |
| CSLH | ac, dc | 57 A to 950 A, 9 A, 45 A | Sink/Source | 3 s | N/A | -25 C to 85 C [-13 F to 185 F] | 6 Vdc to 12 Vdc, 4.5 Vdc to 10.5 Vdc |
2411070913_Honeywell-CSNP661_C3684518.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible