Product Description
The HIH-4010/4020/4021 Series Humidity Sensors are designed for high-volume OEM users, offering a near-linear voltage output for direct input to controllers. With low current draw (typical 200 A), they are suitable for battery-operated systems. Tight sensor interchangeability minimizes OEM calibration costs. These sensors provide instrumentation-quality RH sensing in a competitively priced, solderable SIP package. The HIH-4010 is an uncovered sensor, the HIH-4020 is covered, and the HIH-4021 is covered and condensation-resistant. All models feature a thermoset polymer capacitive sensing element with on-chip signal conditioning, offering excellent resistance to wetting, dust, dirt, oils, and common environmental chemicals. Available in two lead spacing configurations and with or without calibration data printouts.
Product Attributes
- Brand: Honeywell
- Housing Material: Molded thermoset plastic
- Sensor Type: Thermoset polymer capacitive sensing element
- Output: Near linear voltage output vs %RH
- Power: Low power design
- Accuracy: Enhanced accuracy
- Response Time: Fast response time
- Stability: Stable, low drift performance
- Chemical Resistance: Chemically resistant
Technical Specifications
| Parameter | HIH-4010/4020/4021 | Unit | Notes |
|---|---|---|---|
| Interchangeability (0% RH to 59% RH) | -5 to 5 | % RH | First order curve |
| Interchangeability (60% RH to 100% RH) | -8 to 8 | % RH | First order curve |
| Accuracy (best fit straight line) | -3.5 to +3.5 | % RH | 1 |
| Hysteresis | 3 | % RH | Typical |
| Repeatability | 0.5 | % RH | Typical |
| Settling time | 70 | ms | Typical |
| Response time (1/e in slow moving air) | 5 | s | Typical |
| Stability (at 50 %RH in 1 year) | 1.2 | % RH | 2 (Includes testing outside of recommended operating zone) |
| Stability (at 50 %RH in 1 year) | 0.5 | % RH | 3 (Includes testing for recommended operating zone only) |
| Voltage supply | 4 to 5.8 | Vdc | 4 (Device calibrated at 5 Vdc and 25 C) |
| Current supply | 200 to 500 | A | Typical |
| Voltage output (1st order curve fit) | VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16) | V | Typical at 25 C |
| Temperature compensation | True RH = (Sensor RH)/(1.0546 0.00216T) | T in C | |
| Output voltage temp. coefficient at 50% RH, 5 V | -4 | mV/C | Typical |
| Operating temperature | -40 to 85 | C [F] | See Figure 1. |
| Operating humidity (HIH-4010) | 0 to 100 | % RH | 5 (Non-condensing environment) |
| Operating humidity (HIH-4020) | 0 to 100 | % RH | 5 (Non-condensing environment) |
| Operating humidity (HIH-4021) | 0 to 100 | % RH | 5 (Non-condensing environment) |
| Storage temperature | -50 to 125 | C [F] | |
| Storage humidity | See Figure 2. | % RH | 5 (Non-condensing environment) |
Potential Applications
- Refrigeration equipment
- HVAC (Heating, Ventilation and Air Conditioning) equipment
- Medical equipment
- Drying
- Metrology
- Battery-powered systems
- OEM assemblies