CSHV Series Open Loop Current Sensors
The CSHV Series are open-loop Hall-effect current sensors offering a balance of performance and reliability for current sensing. They provide non-intrusive, electrically isolated measurement for primary current ranges of 100 A to 1500 A DC. AEC-Q100 qualified for enhanced quality and reliability, these sensors are ideal for motor control applications where current measurement directly correlates to motor torque and speed. They can be customized to meet specific application needs, supported by global technical assistance.
Product Attributes
- Brand: Honeywell
- Technology: Hall-effect
- Certifications: CE, UKCA, REACH, RoHS compliant
- Qualification: AEC-Q100
- Housing Material: PBT + GF30 %
Technical Specifications
| Characteristic | Symbol | Unit | Parameter | Condition | Min. | Typ. | Max. |
| ABSOLUTE MAXIMUM RATINGS (not operating) | |||||||
| Supply voltage max. | VS max. | V | 10 | ||||
| Reverse supply voltage max. | VR max. | V | -0.3 | ||||
| Output voltage max. | VOUT max. | V | VOUT reverse/forward voltage | -0.3 | 10 | ||
| Output current max. | IOUT max. | mA | -10 | 10 | |||
| Ambient storage temperature | C | -40 | 125 | ||||
| Electrostatic discharge voltage | VESD | kV | 8 | ||||
| RMS voltage for AC isolation test | VDWV | kV | 50 Hz, 1 min | 2.5 | |||
| Creepage distance | dCp | mm | 4.9 | ||||
| Clearance | dCl | mm | 4.9 | ||||
| Comparative tracking index | CTI | PLC3 | |||||
| OPERATING CHARACTERISTICS IN NOMINAL RANGE (IPN) | |||||||
| Primary current, nominal DC | IPN | A | -IPN | IPN | |||
| Supply voltage | VS | V | 4.5 | 5 | 5.5 | ||
| Output voltage (at IP = 0) | VOS | V | TA = 25C, VS = 5 V | 2.500 | |||
| Electrical offset voltage | VOS, ELECT | mV | TA = 25C, VS = 5 V | 3 | |||
| Magnetic offset voltage | VOS, MAG | mV | TA = 25C, VS = 5 V | 2 | |||
| Current consumption | ISUPPLY | mA | TA = 25C, VS = 5 V | 13 | |||
| Load resistance | RL | Ohm | 10k | ||||
| Output impedance | Rout | Ohm | TA = 25C | 1 | |||
| Ratiometric error | r | % | TA = 25C | 0.5 | |||
| Sensitivity | G | mV/A | TA = 25C | 2000/IPN | |||
| Sensitivity error: 100 A to 1200 A | g | % | TA = 25C, VS = 5 V | 0.6 | |||
| Sensitivity error: 1500 A | g | % | TA = 25C, VS = 5 V | 0.8 | |||
| Linearity error | L | % | % of full scale output | TA = 25C, VS = 5 V | -1 | 1 | |
| Ambient operating temperature | C | -40 | 125 | ||||
| Average temperature coefficient VOS, ELECT | mV/C | 0.04 | |||||
| Average temperature coefficient of G | %/C | 0.02 | |||||
| Step response time (10 % to 90 %) | tr | s | 2 | 6 | |||
| Frequency bandwidth | BW | kHz | -3 dB | 45 | |||
| Output RMS noise (RMS) | mV | 2 | |||||
| ORDER GUIDE | |||||||
| Catalog Listing | Measure Range (A) | Sensitivity (mV/A at VS = 5 V) | Offset (mV at VS = 5 V) | Accuracy (% at VS = 5 V) 25C | Accuracy (% at VS = 5 V) -40C to 85C / -40C to 125C | ||
| CSHV100A-001 | 100 | 20 | 7 mV | 1 % | 2 % | ||
| CSHV200A-001 | 200 | 10 | 7 mV | 1 % | 2 % | ||
| CSHV300A-001 | 300 | 6.667 | 7 mV | 1 % | 2 % | ||
| CSHV400A-001 | 400 | 5 | 7 mV | 1 % | 2 % | ||
| CSHV500A-001 | 500 | 4 | 7 mV | 1 % | 2 % | ||
| CSHV600A-001 | 600 | 3.333 | 7 mV | 1 % | 2 % | ||
| CSHV700A-001 | 700 | 2.857 | 7 mV | 1 % | 2 % | ||
| CSHV800A-001 | 800 | 2.5 | 7 mV | 1 % | 2 % | ||
| CSHV900A-001 | 900 | 2.222 | 7 mV | 1 % | 2 % | ||
| CSHV1000A-001 | 1000 | 2 | 7 mV | 1 % | 2 % | ||
| CSHV1100A-001 | 1100 | 1.818 | 7 mV | 1 % | 2 % | ||
| CSHV1200A-001 | 1200 | 1.667 | 7 mV | 1 % | 2 % | ||
| CSHV1500A-001 | 1500 | 1.333 | 7 mV | 2 % | 3 % | ||
| MECHANICAL CHARACTERISTICS | |||||||
| Housing material | PBT + GF30 % | ||||||
| Mounting screw | M4, 2,5 N m torque max. | ||||||
| Mating electrical connector | TE MPN 1473672-1 | ||||||
| Weight | g | 58 g | |||||
2411261441_Honeywell-CSHV300A-001_C7115894.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible