CSHV Series Open Loop Current Sensors
The CSHV Series are open-loop Hall-effect current sensors designed for reliable and high-performance current sensing. These non-intrusive, electrically isolated sensors offer a simple sensing method with a primary current measurement range of 100 A to 1500 A DC. They are AEC-Q100 qualified, ensuring high quality and reliability for demanding applications such as motor control in electrified vehicles, battery management systems, energy storage systems, and fault detection in heavy industrial equipment. The sensors provide accurate current measurement directly proportional to motor torque, enabling precise speed determination. Customizable solutions are available to meet specific application needs, backed by global technical assistance from Honeywell.
Product Attributes
- Brand: Honeywell
- Technology: Hall-effect sensing
- Certifications: CE, UKCA, REACH, RoHS compliant
- Qualification: AEC-Q100
- Housing Material: PBT + GF30 %
- Mounting Screw: M4, 2.5 N m torque max.
- Mating Electrical Connector: TE MPN 1473672-1
- Weight: 58 g
Technical Specifications
| Catalog Listing | Measure Range (A) | Sensitivity (mV/A at VS = 5 V) | Offset (mV at VS = 5 V) | Accuracy (% at VS = 5 V) 25C | Accuracy (% at VS = 5 V) -40C to 85C | Accuracy (% at VS = 5 V) -40C to 125C |
| CSHV100A-001 | 100 | 20 | 7 mV | 1 % | 2 % | |
| CSHV200A-001 | 200 | 10 | 7 mV | 1 % | 2 % | |
| CSHV300A-001 | 300 | 6.667 | 7 mV | 1 % | 2 % | 2 % |
| CSHV400A-001 | 400 | 5 | 7 mV | 1 % | 2 % | 2 % |
| CSHV500A-001 | 500 | 4 | 7 mV | 1 % | 2 % | 2 % |
| CSHV600A-001 | 600 | 3.333 | 7 mV | 1 % | 2 % | 2 % |
| CSHV700A-001 | 700 | 2.857 | 7 mV | 1 % | 2 % | 2 % |
| CSHV800A-001 | 800 | 2.5 | 7 mV | 1 % | 2 % | 2 % |
| CSHV900A-001 | 900 | 2.222 | 7 mV | 1 % | 2 % | 2 % |
| CSHV1000A-001 | 1000 | 2 | 7 mV | 1 % | 2 % | 2 % |
| CSHV1100A-001 | 1100 | 1.818 | 7 mV | 1 % | 2 % | 2 % |
| CSHV1200A-001 | 1200 | 1.667 | 7 mV | 1 % | 2 % | 2 % |
| CSHV1500A-001 | 1500 | 1.333 | 7 mV | 2 % | 3 % | 3 % |
| Characteristic | Symbol | Unit | Parameter | Condition | Min. | Typ. | Max. |
| Supply voltage max. | VS max. | V | 10 | ||||
| Reverse supply voltage max. | VR max. | V | -0.3 | ||||
| Output voltage max. | VOUT max. | V | VOUT reverse/forward voltage | -0.3 | 10 | ||
| Output current max. | IOUT max. | mA | -10 | 10 | |||
| Ambient storage temperature | C | -40 | 125 | ||||
| Electrostatic discharge voltage | VESD | kV | 8 | ||||
| RMS voltage for AC isolation test | VDWV | kV | 50 Hz, 1 min | 2.5 | |||
| Creepage distance | dCp | mm | 4.9 | ||||
| Clearance | dCl | mm | 4.9 | ||||
| Comparative tracking index | CTI | PLC3 | |||||
| Primary current, nominal DC | IPN | A | -IPN | IPN | |||
| Supply voltage | VS | V | 4.5 | 5 | 5.5 | ||
| Output voltage (at IP = 0) | VOS | V | TA = 25C, VS = 5 V | 2.500 | |||
| Electrical offset voltage | VOS, ELECT | mV | TA = 25C, VS = 5 V | 3 | |||
| Magnetic offset voltage | VOS, MAG | mV | TA = 25C, VS = 5 V | 2 | |||
| Current consumption | ISUPPLY | mA | TA = 25C, VS = 5 V | 13 | |||
| Load resistance | RL | Ohm | 10k | ||||
| Output impedance | Rout | Ohm | TA = 25C | 1 | |||
| Ratiometric error | r | % | TA = 25C | 0.5 | |||
| Sensitivity error: 100 A to 1200 A | g | % | TA = 25C, VS = 5 V | 0.6 | |||
| Sensitivity error: 1500 A | g | % | TA = 25C, VS = 5 V | 0.8 | |||
| Linearity error | L | % | % of full scale output | TA = 25C, VS = 5 V | -1 | 1 | |
| Ambient operating temperature | C | -40 | 125 | ||||
| Average temperature coefficient VOS, ELECT | mV/C | 0.04 | |||||
| Average temperature coefficient of G | %/C | 0.02 | |||||
| Step response time (10 % to 90 %) | tr | s | 2 | 6 | |||
| Frequency bandwidth | BW | kHz | -3 dB | 45 | |||
| Output RMS noise (RMS) | mV | 2 |
2411261441_Honeywell-CSHV900A-001_C7233374.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible