Specifications
working temperature:
-40℃~+125℃
Current Range:
±900A
Voltage - Supply:
4.5V~5.5V
Sensitivity:
2.222mV/A
Mfr. Part #:
CSHV900A-001
Key Attributes
Model Number: CSHV900A-001
Product Description

CSHV Series Open Loop Current Sensors

The CSHV Series are open-loop Hall-effect current sensors designed for reliable and high-performance current sensing. These non-intrusive, electrically isolated sensors offer a simple sensing method with a primary current measurement range of 100 A to 1500 A DC. They are AEC-Q100 qualified, ensuring high quality and reliability for demanding applications such as motor control in electrified vehicles, battery management systems, energy storage systems, and fault detection in heavy industrial equipment. The sensors provide accurate current measurement directly proportional to motor torque, enabling precise speed determination. Customizable solutions are available to meet specific application needs, backed by global technical assistance from Honeywell.

Product Attributes

  • Brand: Honeywell
  • Technology: Hall-effect sensing
  • Certifications: CE, UKCA, REACH, RoHS compliant
  • Qualification: AEC-Q100
  • Housing Material: PBT + GF30 %
  • Mounting Screw: M4, 2.5 N m torque max.
  • Mating Electrical Connector: TE MPN 1473672-1
  • Weight: 58 g

Technical Specifications

Catalog ListingMeasure Range (A)Sensitivity (mV/A at VS = 5 V)Offset (mV at VS = 5 V)Accuracy (% at VS = 5 V) 25CAccuracy (% at VS = 5 V) -40C to 85CAccuracy (% at VS = 5 V) -40C to 125C
CSHV100A-001100207 mV1 %2 %
CSHV200A-001200107 mV1 %2 %
CSHV300A-0013006.6677 mV1 %2 %2 %
CSHV400A-00140057 mV1 %2 %2 %
CSHV500A-00150047 mV1 %2 %2 %
CSHV600A-0016003.3337 mV1 %2 %2 %
CSHV700A-0017002.8577 mV1 %2 %2 %
CSHV800A-0018002.57 mV1 %2 %2 %
CSHV900A-0019002.2227 mV1 %2 %2 %
CSHV1000A-001100027 mV1 %2 %2 %
CSHV1100A-00111001.8187 mV1 %2 %2 %
CSHV1200A-00112001.6677 mV1 %2 %2 %
CSHV1500A-00115001.3337 mV2 %3 %3 %
CharacteristicSymbolUnitParameterConditionMin.Typ.Max.
Supply voltage max.VS max.V10
Reverse supply voltage max.VR max.V-0.3
Output voltage max.VOUT max.VVOUT reverse/forward voltage-0.310
Output current max.IOUT max.mA-1010
Ambient storage temperatureC-40125
Electrostatic discharge voltageVESDkV8
RMS voltage for AC isolation testVDWVkV50 Hz, 1 min2.5
Creepage distancedCpmm4.9
ClearancedClmm4.9
Comparative tracking indexCTIPLC3
Primary current, nominal DCIPNA-IPNIPN
Supply voltageVSV4.555.5
Output voltage (at IP = 0)VOSVTA = 25C, VS = 5 V2.500
Electrical offset voltageVOS, ELECTmVTA = 25C, VS = 5 V3
Magnetic offset voltageVOS, MAGmVTA = 25C, VS = 5 V2
Current consumptionISUPPLYmATA = 25C, VS = 5 V13
Load resistanceRLOhm10k
Output impedanceRoutOhmTA = 25C1
Ratiometric errorr%TA = 25C0.5
Sensitivity error: 100 A to 1200 Ag%TA = 25C, VS = 5 V0.6
Sensitivity error: 1500 Ag%TA = 25C, VS = 5 V0.8
Linearity errorL%% of full scale outputTA = 25C, VS = 5 V-11
Ambient operating temperatureC-40125
Average temperature coefficient VOS, ELECTmV/C0.04
Average temperature coefficient of G%/C0.02
Step response time (10 % to 90 %)trs26
Frequency bandwidthBWkHz-3 dB45
Output RMS noise (RMS)mV2