CUI Devices PS02 Series Pressure Sensor
Product Overview
The CUI Devices PS02 Series is a versatile pressure sensor designed for accurate measurement of absolute, gauge, and sealed gauge pressures. Featuring a temperature-compensated stainless steel housing with an O-ring seal, this sensor offers multiple pressure range options and a digital I2C output for seamless integration into various systems. Its robust construction and reliable performance make it suitable for applications involving compatible liquids and gases.
Product Attributes
- Brand: CUI Devices
- Series: PS02
- Housing Material: Stainless Steel 316L
- Diaphragm Material: Stainless Steel 316L
- Seal: O-ring (NBR black)
- Certifications: RoHS
- Warranty: One (1) year limited warranty
Technical Specifications
| Parameter | Conditions/Description | Min | Typ | Max | Units |
|---|---|---|---|---|---|
| General Specifications | |||||
| Pressure Range | See Pressure Specifications | 0 | - | 6 | MPa |
| Pressure Reference | Gauge pressure, Absolute pressure, Sealed gauge pressure | - | - | - | - |
| Excitation | - | 3.1 | 3.3 | 3.6 | V |
| Current Consumption (Working) | - | - | 3 | - | mA |
| Current Consumption (Standby) | - | 0.1 | - | - | mA |
| Output Signal | I2C (14 bit) | - | - | - | - |
| I2C Slave Address | - | - | 0x06D | - | - |
| Data Ready Time | - | - | 2 | - | ms |
| Response Time | - | - | 3 | - | ms |
| Insulation Resistance | at 250 Vdc | 200 | - | - | M |
| Vibration | - | - | 20 G (20~5,000 Hz) | - | - |
| Shock | - | - | 100 G for 10 ms | - | - |
| Compensated Temperature | <100 kPa models | 0 | - | 60 | C |
| Compensated Temperature | All other models | -20 | - | 85 | C |
| Operating Temperature | - | -40 | - | 105 | C |
| Storage Temperature | - | -40 | - | 125 | C |
| Life | - | - | 1,000,000 cycles | - | - |
| Mechanical Specifications | |||||
| Measured Medium | All 316L compatible liquids and gases | - | - | - | - |
| Housing/Diaphragm | Stainless steel 316L | - | - | - | - |
| Dimensions | - | - | 19 x 14 | - | mm |
| Weight | - | 19 | - | 25 | g |
| Basic Parameters | |||||
| Accuracy1 | In the compensation temperature range, refer to 25C. | 0.5 | - | - | %FS |
| Hysteresis | - | 0.05 | - | 0.1 | %FS |
| Repeatability | - | 0.05 | - | 0.1 | %FS |
| Zero Temperature Drift1 | - | 1.0 | - | 1.5 | %FS |
| Span Temperature Drift1 | - | 1.0 | - | 1.5 | %FS |
| Thermal Hysteresis | - | 0.05 | - | 0.2 | %FS |
| Long Term Stability | - | - | 0.25 | - | %FS/year |
| Pressure Specifications | |||||
| Pressure Range | Pressure Reference2 | Overload Pressure | Burst Pressure | - | - |
| 0~35 kPa | G | 300%FS | 400%FS | - | - |
| 0~100 kPa | G, A | 200%FS | 300%FS | - | - |
| 0~250 kPa | G | 200%FS | 300%FS | - | - |
| 0~600 kPa | G | 200%FS | 300%FS | - | - |
| 0~1.0 MPa | G | 200%FS | 300%FS | - | - |
| 0~1.6 MPa | G, S | 200%FS | 300%FS | - | - |
| 0~2.5 MPa | G, S | 200%FS | 300%FS | - | - |
| 0~4.0 MPa | S | 200%FS | 300%FS | - | - |
| 0~6.0 MPa | S | 200%FS | 300%FS | - | - |
| Part Number Key | |||||
| Base Number: PS02 - X XXXX P - 4W | |||||
| Pressure Reference | A = Absolute, G = Gauge, S = Sealed Gauge | - | - | - | - |
| Pressure Range | 350K = 35 kPa, 100K = 100 kPa, 250K = 250 kPa, 600K = 600 kPa, 100M = 1 MPa, 160M = 1.6 MPa, 250M = 2.5 MPa, 400M = 4 MPa, 600M = 6 MPa | - | - | - | - |
| I2C Timing Characteristics | |||||
| SCL Clock Frequency | - | - | 100 - 400 | - | kHz |
| Start Condition Hold Time | relative to SCL edge | - | 0.6 | - | s |
| SCL Clock Low Width (Min) | - | - | 1.3 | - | s |
| SCL Clock High Width (Min) | - | - | 0.6 | - | s |
| Start Condition Setup Time | relative to SCL edge | - | 0.6 | - | s |
| Data Hold Time | on SDA relative to SCL edge | - | 0.6 | - | s |
| Data Setup Time | on SDA relative to SCL edge | - | 0.1 | - | s |
| Stop Condition Setup Time | on SCL | - | 0.6 | - | s |
| Bus Free Time | between stop and start condition | - | 1.3 | - | s |
Usage Considerations
- Avoid touching the diaphragm with hard objects to prevent damage.
- Strictly follow wiring methods to prevent product damage or faults.
- Misuse may lead to danger or personal injury.
- Pressure range selection should be within 30%FS of actual conditions.
- Pressure references include gauge (based on current atmospheric pressure), absolute (based on vacuum), and sealed gauge (calibrated to production site atmospheric pressure).
- Confirm system overload capacity is less than the sensor's overload protection limit to maintain product life.
- Gauge pressure sensors cannot substitute for negative pressure sensors due to material and manufacturing differences.
2411200037_CUI-PS02-G250MP-4W_C3257758.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible