Product Overview
The CUI Devices PS04 Series Pressure Sensor is a temperature-compensated sensor designed for measuring gauge pressure. It offers multiple pressure range options and features a stainless steel housing with an O-ring seal. This sensor is suitable for use with compatible liquids and gases and is built for reliability with a life expectancy of 1,000,000 cycles. It is RoHS compliant.Product Attributes
- Brand: CUI Devices
- Series: PS04
- Pressure Reference: Gauge Pressure
- Housing Material: Stainless Steel 316L
- Diaphragm Material: Stainless Steel 316L
- Seal Material: NBR (O-ring)
- Certifications: RoHS
- Warranty: One (1) year limited warranty
Technical Specifications
| Parameter | Conditions/Description | Min | Typ | Max | Units |
|---|---|---|---|---|---|
| Pressure Range | See Pressure Specifications | 0 | 2.5 | MPa | |
| Excitation (Constant Current) | - | 1.5 | - | 10 | mA |
| Excitation (Constant Voltage) | - | - | 2.5 | 15 | V |
| Input Impedance (Constant Current) | - | 2 | - | 5 | k |
| Input Impedance (Constant Voltage) | - | 3 | - | 18 | k |
| Insulation Resistance | at 250 Vdc | 200 | - | - | M |
| Response Time | up to 90%FS | - | - | 1 | ms |
| Vibration | (20~5,000 Hz) | - | 20 | - | G |
| Shock | for 10 ms | - | 100 | - | G |
| Compensated Temperature (Constant Current) | 35 kPa models | - | - | 35 | C |
| Compensated Temperature (All Other Models) | - | 0 | - | 60 | C |
| Compensated Temperature (Constant Voltage) | - | -20 | - | 85 | C |
| Operating Temperature | - | -40 | - | 125 | C |
| Storage Temperature | - | -40 | - | 125 | C |
| Life | - | - | 1,000,000 | - | cycles |
| Measured Medium | all 316L compatible liquids and gases | - | - | - | - |
| Dimensions | - | - | 19 x 14 | - | mm |
| Weight | - | - | 80 | - | g |
| Nonlinearity1 | - | -0.3 | 0.2 | 0.3 | %FS |
| Hysteresis | - | -0.05 | 0.03 | 0.05 | %FS |
| Repeatability | - | -0.05 | 0.03 | 0.05 | %FS |
| Zero Output | - | -2 | 0.2 | 2 | mV |
| Full Scale Span Output (Constant Current; 35 kPa models) | - | - | 40 | 60 | mV |
| Full Scale Span Output (Constant Current; all other models) | - | - | 60 | 90 | mV |
| Full Scale Span Output (Constant Voltage; 35 kPa models) | - | - | 90 | 150 | mV |
| Full Scale Span Output (Constant Voltage; all other models) | - | - | 90 | 120 | mV |
| Zero Temperature Coefficient2 (10 kPa models) | - | -2 | 1.5 | 2 | %FS |
| Zero Temperature Coefficient2 (All other models) | - | -1.5 | 0.75 | 1.5 | %FS |
| Span Temperature Coefficient2 | - | -1.5 | 0.75 | 1.5 | %FS |
| Thermal Hysteresis3 | - | -0.075 | 0.05 | 0.075 | %FS |
| Long Term Stability | - | -0.3 | 0.2 | 0.3 | %FS/year |
| Overload Pressure | See Pressure Specifications | - | 200%FS | - | - |
| Burst Pressure | See Pressure Specifications | - | 500%FS | - | - |
Pressure Specifications:
| Pressure Range | Pressure Reference4 | Overload Pressure | Burst Pressure |
|---|---|---|---|
| 0~10 kPa | G | 200%FS | 500%FS |
| 0~20 kPa | G | 200%FS | 500%FS |
| 0~35 kPa | G | 200%FS | 500%FS |
| 0~70 kPa | G | 200%FS | 500%FS |
| 0~100 kPa | G | 200%FS | 500%FS |
| 0~160 kPa | G | 200%FS | 500%FS |
| 0~250 kPa | G | 200%FS | 400%FS |
| 0~400 kPa | G | 200%FS | 400%FS |
| 0~800 kPa | G | 200%FS | 400%FS |
| 0~1 MPa | G | 200%FS | 400%FS |
| 0~1.6 MPa | G | 150%FS | 400%FS |
| 0~2.5 MPa | G | 150%FS | 300%FS |
Part Number Key:
Base Number: PS04
Pressure Range Options: 10K (10 kPa), 20K (20 kPa), 35K (35 kPa), 70K (70 kPa), 100K (100 kPa), 160K (160 kPa), 250K (250 kPa), 400K (400 kPa), 800K (800 kPa), 10M (1 MPa), 16M (1.6 MPa), 25M (2.5 MPa)
Pressure Reference: G (Gauge)
Excitation: A (1.5 mA), V (10 V)
Wire Connections:
- Red: +IN
- Blue: -IN
- Yellow: +OUT
- White: -OUT
Usage Considerations:
- Avoid touching the diaphragm with hard objects.
- Strictly follow wiring methods to prevent product damage.
- Misuse may lead to danger or personal injury.
- Select pressure range within 30%FS of actual conditions.
- Pressure reference types include gauge, absolute, and sealed gauge.
- Confirm system's maximum overload is within sensor limits.
- Gauge pressure sensors cannot substitute for negative pressure sensors.
2411200037_CUI-PS04-G25MP-V4W_C3257976.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible