Product Overview
The CUI Devices PS05 Series Pressure Sensor is designed for accurate pressure measurement with temperature compensation. It offers multiple pressure range options and can be configured for absolute or sealed gauge pressure. Featuring a durable stainless steel housing and an O-ring seal, this sensor is suitable for use with 316L compatible liquids and gases. Its robust construction and reliable performance make it ideal for various industrial applications.
Product Attributes
- Brand: CUI Devices
- Series: PS05
- Material (Housing/Diaphragm): Stainless Steel 316L
- Seal Material: NBR (4 MPa models), Fluorine Rubber (>4 MPa models)
- Measured Medium: 316L compatible liquids and gases
- Certifications: RoHS
- Warranty: One (1) year limited warranty
Technical Specifications
| Parameter | Conditions/Description | Min | Typ | Max | Units |
|---|---|---|---|---|---|
| Pressure Range | See Pressure Specifications | 0 | - | 100 | MPa |
| Pressure Reference | Absolute pressure, sealed gauge pressure | - | - | - | - |
| Excitation | - | 1.5 | - | 2.5 | mA |
| Input Impedance | - | 2 | - | 5 | k |
| Insulation Resistance | at 250 Vdc | 200 | - | - | M |
| Response Time | up to 90%FS | - | - | 1 | ms |
| Vibration | - | - | - | 20 | G (20~5,000 Hz) |
| Shock | - | - | - | 100 | G for 10 ms |
| Compensated Temperature | 35 kPa models | 0 | - | 60 | C |
| Compensated Temperature | all other models | -10 | - | 70 | C |
| Operating Temperature | - | -40 | - | 125 | C |
| Storage Temperature | - | -40 | - | 125 | C |
| Life | - | - | 1,000,000 | - | cycles |
| Measured Medium | all | - | - | - | 316L compatible liquids and gases |
| Housing/Diaphragm | - | - | - | - | Stainless steel 316L |
| Dimensions | - | - | - | 19 x 14 | mm |
| Weight | - | - | - | 80 | g |
| Nonlinearity1 | - | -0.3 | 0.2 | 0.3 | %FS |
| Hysteresis | - | -0.05 | 0.03 | 0.05 | %FS |
| Repeatability | - | -0.05 | 0.03 | 0.05 | %FS |
| Zero Output | - | -2 | 0.2 | 2 | mV |
| Full Scale Span Output | 35 kPa models | - | 40 | - | mV |
| Full Scale Span Output | all other models | - | 90 | - | mV |
| Zero Temperature Coefficient2 | 10 kPa models | -2 | 1.5 | 2 | %FS |
| Zero Temperature Coefficient2 | all other models | -1.5 | 0.75 | 1.5 | %FS |
| Span Temperature Coefficient2 | - | -1.5 | 0.75 | 1.5 | %FS |
| Thermal Hysteresis3 | - | -0.075 | 0.05 | 0.075 | %FS |
| Long Term Stability | - | -0.3 | 0.2 | 0.3 | %FS/year |
| Pressure Range | 0~100 kPa | - | - | - | A4 |
| Overload Pressure | 0~100 kPa | - | - | 200%FS | - |
| Burst Pressure | 0~100 kPa | - | - | 500%FS | - |
| Pressure Range | 0~250 kPa | - | - | - | A4 |
| Overload Pressure | 0~250 kPa | - | - | 200%FS | - |
| Burst Pressure | 0~250 kPa | - | - | 500%FS | |
| Pressure Range | 0~400 kPa | - | - | - | A4 |
| Overload Pressure | 0~400 kPa | - | - | 200%FS | - |
| Burst Pressure | 0~400 kPa | - | - | 500%FS | - |
| Pressure Range | 0~1.0 MPa | - | - | - | A4 |
| Overload Pressure | 0~1.0 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~1.0 MPa | - | - | 500%FS | - |
| Pressure Range | 0~1.6 MPa | - | - | - | A, S4 |
| Overload Pressure | 0~1.6 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~1.6 MPa | - | - | 500%FS | - |
| Pressure Range | 0~2.5 MPa | - | - | - | S4 |
| Overload Pressure | 0~2.5 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~2.5 MPa | - | - | 500%FS | - |
| Pressure Range | 0~4.0 MPa | - | - | - | S4 |
| Overload Pressure | 0~4.0 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~4.0 MPa | - | - | 400%FS | - |
| Pressure Range | 0~6.0 MPa | - | - | - | S4 |
| Overload Pressure | 0~6.0 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~6.0 MPa | - | - | 400%FS | - |
| Pressure Range | 0~10 MPa | - | - | - | S4 |
| Overload Pressure | 0~10 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~10 MPa | - | - | 400%FS | - |
| Pressure Range | 0~16 MPa | - | - | - | S4 |
| Overload Pressure | 0~16 MPa | - | - | 200%FS | - |
| Burst Pressure | 0~16 MPa | - | - | 400%FS | - |
| Pressure Range | 0~25 MPa | - | - | - | S4 |
| Overload Pressure | 0~25 MPa | - | - | 150%FS | - |
| Burst Pressure | 0~25 MPa | - | - | 400%FS | - |
| Pressure Range | 0~40 MPa | - | - | - | S4 |
| Overload Pressure | 0~40 MPa | - | - | 150%FS | - |
| Burst Pressure | 0~40 MPa | - | - | 300%FS | - |
| Pressure Range | 0~60 MPa | - | - | - | S4 |
| Overload Pressure | 0~60 MPa | - | - | 150%FS | - |
| Burst Pressure | 0~60 MPa | - | - | 300%FS | - |
| Pressure Range | 0~100 MPa | - | - | - | S4 |
| Overload Pressure | 0~100 MPa | - | - | 150%FS | - |
| Burst Pressure | 0~100 MPa | - | - | 300%FS | - |
Notes:
1 Calculated according to best fit straight line (BFSL) least square method.
2 In the compensated temperature range, refer to 30C.
3 After passing high and low temperature, return to the reference temperature.
4 A=absolute pressure (vacuum is zero); S=sealed gauge pressure (calibrated atmospheric pressure is zero).
2411200037_CUI-PS05-S16MP-5W_C3255190.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible