Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Versatile pressure sensor CUI PS03-A250KP-A4W designed for accurate measurement of liquids and gases factory
<
quality Versatile pressure sensor CUI PS03-A250KP-A4W designed for accurate measurement of liquids and gases factory
>
Specifications
Pressure range:
0Kpa~2.5bar
Mfr. Part #:
PS03-A250KP-A4W
Key Attributes
Model Number: PS03-A250KP-A4W
Product Description

CUI Devices PS03 Series Pressure Sensor

The CUI Devices PS03 Series Pressure Sensor is a versatile and reliable sensor designed for accurate pressure measurement in a wide range of industrial applications. Featuring temperature compensation, multiple pressure range options, and both absolute and sealed gauge pressure configurations, this sensor offers flexibility for diverse system requirements. Its robust stainless steel housing and O-ring seal ensure durability and reliable performance in demanding environments. The PS03 series is suitable for measuring compatible liquids and gases.

Product Attributes

  • Brand: CUI Devices
  • Series: PS03
  • Housing Material: Stainless Steel 316L
  • Diaphragm Material: Stainless Steel 316L
  • O-ring Material: NBR (4 Mpa models), Fluorine Rubber (>4 Mpa models)
  • Certifications: RoHS
  • Warranty: One (1) year limited warranty

Technical Specifications

Parameter Conditions/Description Min Typ Max Units
General Specifications
Pressure Range See Pressure Specifications 0 100 MPa
Pressure Reference Absolute pressure, sealed gauge pressure
Excitation Constant current models 1.5 mA
Excitation Constant voltage models 10 15 V
Input Impedance Constant current models 2 5 k
Input Impedance Constant voltage models 18 k
Insulation Resistance at 250 Vdc 200 M
Response Time up to 90%FS 1 ms
Vibration 20 G (20~5,000 Hz)
Shock for 10 ms 100 G
Compensated Temperature Constant current models (35 kPa models) 0 60 C
Compensated Temperature All other models (constant current) -10 70 C
Compensated Temperature Constant voltage models 0 70 C
Operating Temperature -40 125 C
Storage Temperature -40 125 C
Life 1,000,000 cycles
Mechanical Specifications
Measured Medium All 316L compatible liquids and gases
Housing/Diaphragm Stainless steel 316L
Dimensions 19 x 14 mm
Weight 80 g
Basic Parameters
Nonlinearity1 -0.3 0.2 0.3 %FS
Hysteresis -0.05 0.03 0.05 %FS
Repeatability -0.05 0.03 0.05 %FS
Zero Output -2 0.2 2 mV
Full Scale Span Output Constant current; 35 kPa models 40 mV
Full Scale Span Output Constant current; all other models 90 mV
Full Scale Span Output Constant voltage; 35 kPa models 60 mV
Full Scale Span Output Constant voltage; all other models 150 mV
Zero Temperature Coefficient2 10 kPa models -2 1.5 2 %FS
Zero Temperature Coefficient2 All other models -1.5 0.75 1.5 %FS
Span Temperature Coefficient2 -1.5 0.75 1.5 %FS
Thermal Hysteresis3 -0.075 0.05 0.075 %FS
Long Term Stability -0.3 0.2 0.3 %/year
Pressure Specifications
Pressure Range 0~100 kPa A 200%FS 500%FS
Pressure Range 0~250 kPa A 200%FS 500%FS
Pressure Range 0~400 kPa A 200%FS 500%FS
Pressure Range 0~1.0 MPa A 200%FS 500%FS
Pressure Range 0~1.6 MPa A, S 200%FS 500%FS
Pressure Range 0~2.5 MPa S 200%FS 500%FS
Pressure Range 0~4.0 MPa S 200%FS 400%FS
Pressure Range 0~6.0 MPa S 200%FS 400%FS
Pressure Range 0~10 MPa S 200%FS 400%FS
Pressure Range 0~16 MPa S 200%FS 400%FS
Pressure Range 0~25 MPa S 150%FS 400%FS
Pressure Range 0~40 MPa S 150%FS 300%FS
Pressure Range 0~60 MPa S 150%FS 300%FS
Pressure Range 0~100 MPa S 150%FS 300%FS

Usage Considerations

  • Avoid touching the diaphragm with hard objects to prevent damage.
  • Strictly follow the wiring method to prevent product damage or faults.
  • Misuse may lead to danger or personal injury.
  • When selecting a pressure range, it should be within 30%FS of the actual conditions.
  • Pressure reference options include gauge pressure, absolute pressure, and sealed gauge pressure.
  • Confirm the maximum overload of the applied system is less than the sensor's overload protection limit to avoid affecting product life or causing damage.
  • Gauge pressure sensors cannot substitute for negative pressure sensors due to differences in manufacturing materials and processes.

2411200037_CUI-PS03-A250KP-A4W_C3259820.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max