Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Accurate and stable temperature humidity transmitter CYBERSEN CHT WS R with digital linearization correction factory
<
quality Accurate and stable temperature humidity transmitter CYBERSEN CHT WS R with digital linearization correction factory
>
Specifications
Humidity Tolerance:
±3%RH
Temperature Range:
-55℃~+120℃
Humidity:
0%RH~100%RH
Temperature Tolerance:
±0.2℃
Mfr. Part #:
CHT-WS-R
Key Attributes
Model Number: CHT-WS-R
Product Description

CHT-WS Series Wall-mounted Temperature and Humidity Transmitter

The CHT-WS Series wall-mounted temperature and humidity transmitter utilizes imported digital temperature and humidity sensors that have undergone precise calibration. This calibration data is stored in the internal memory. The transmitter offers digital output for both relative humidity and temperature, ensuring full interchangeability without complex calibration processes. It excels in measurement accuracy, linearity, repeatability, interchangeability, and consistency, making it suitable for environmental equipment integration, instrument integration, and general environmental testing.

Key Features:

  • High cost-performance with wide voltage design.
  • Digital linearization correction for high accuracy and stability.
  • Full-range temperature compensation, wide temperature and humidity measurement range, with selectable measurement ranges.
  • Flexible installation and convenient use.
  • Compact size, lightweight, and vibration resistant.
  • Available in multiple form factors to meet diverse customer needs.

Application Scenarios:

Widely used in building automation, telecommunication equipment rooms, papermaking, warehousing and logistics, shopping malls, hotels, cinemas, train stations, museums, theaters, agricultural greenhouses, hospitals, meteorology, clean workshops, and other fields requiring air temperature and humidity measurement.

Product Specifications:

ParameterSpecification
Temperature RangeStandard: -40~80; Other ranges customizable
Humidity Range0~100%RH (non-condensing)
Accuracy0.2 (@25); 3%RH (10%~90%)
Repeatability0.1; 0.1%RH
Long-term Stability<0.04/year; <0.5%RH/year
Output SignalV: Voltage signal (0~2V, 0~5V, 0~10V selectable); I: 4~20mA (current loop); R: RS485 (Modbus-RTU protocol, default address: 01)
Supply Voltage10~30V DC
Response Time<1S
Working EnvironmentTemperature: -55~120; Humidity: 95%RH
Load CapacityVoltage output: Output resistance 250; Current output: 600

Usage Instructions:

The air temperature and humidity sensor can be connected to various differential input data acquisition devices, data acquisition cards, remote data acquisition modules, etc. Please refer to the wiring diagram for details.

Data Conversion Methods:

Temperature Conversion:

  • 0~2V DC: T = 50*V - 30
  • 0~5V DC: T = 20*V - 30
  • 0~10V DC: T = 10*V - 30
  • 4~20mA: T = 6.25*A - 55

Humidity Conversion:

  • 0~2V DC: H = 50*V
  • 0~5V DC: H = 20*V
  • 0~10V DC: H = 10*V
  • 4~20mA: H = 6.25*A - 25

RS485 Signal:

Standard Modbus-RTU protocol, Baud rate: 4800; Parity: None; Data bits: 8; Stop bits: 1.

Address Modification:

To change the address (e.g., from 1 to 2), use the following command structure: Host Slave. Example: 0x01 0x06 0x07 0xD0 0x00 0x02 0x08 0x86. If the sensor receives correctly, it will return data as per the original path. If the original address is forgotten, the broadcast address 0xFF can be used (only one slave can be connected to the host). The returned address will be the original address, which can be used for address querying.

Data Query:

To query data (temperature, humidity) from a sensor (address 1), use the following command: Host Slave. Example: 0x01 0x03 0x00 0x00 0x00 0x02 0xC4 0x0B. If the sensor receives correctly, it will return data: Slave Host. Example: 0x01 0x03 0x04 0xFF 0xDD 0x01 0x64 0x5A 0x66. Temperature: -3.5 (negative numbers are represented in two's complement); Humidity: 35.6%RH.

Precautions:

  • Upon receiving the product, please check if the packaging is intact and verify that the sensor model and specifications match your order.
  • Installation location should be away from chemically corrosive environments.
  • Sensors and wires should be kept away from high-voltage electricity, heat sources, etc.
  • The sensor is a precision instrument and should be stored in a dry, ventilated, and normal temperature indoor environment.
  • The sensor is a precision component; please do not disassemble it yourself to avoid product damage.