Product Overview
The HS1V H03 SERIES is an open-loop Hall effect current sensor designed for the electronic measurement of DC, AC, and pulsed currents. It provides galvanic separation between primary and secondary circuits, featuring an output voltage proportional to the supply voltage. Its small size, insulating plastic case (UL 94-V0), and lack of insertion losses make it suitable for various demanding applications.
Product Attributes
- Brand: CHIPSENSE
- Certifications: UL 94-V0, IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010
- Material: Insulating plastic case
Technical Specifications
| Model Number | Primary Nominal RMS Current (IPN) | Primary Current Measuring Range (IPM) | Supply Voltage (VC) | Current Consumption (IC) | Load Resistance (RL) | Output Voltage (VOUT) @ IP N | Theoretical Sensitivity (Gth) | Sensitivity Error (G) | Linearity Error (L) | Accuracy @ IP N (X) | Response Time @ 90% (tr) | Frequency Bandwidth (-3dB) (BW) |
| HS1V 50 H03 | 50 A | -150 to 150 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 80.00 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 100 H03 | 100 A | -300 to 300 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 40.00 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 200 H03 | 200 A | -600 to 600 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 20.00 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 300 H03 | 300 A | -900 to 900 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 13.33 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 400 H03 | 400 A | -900 to 900 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 10.00 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 500 H03 | 500 A | -900 to 900 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 8.00 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
| HS1V 600 H03 | 600 A | -900 to 900 A | 12 to 18 V | 32 mA (Typ) | 10 k | 4.000 V | 6.67 mV/A | -0.5 to 0.5 % | -0.5 to 0.5 % of IPN | -1 to 1 % of IPN | 3 s | 50 kHz |
Applications
AC variable speed, Uninterruptible Power Supply (UPS), Static converters for DC motor drives, Switch Mode Power Supplies (SMPS), Power supplies for welding applications, Battery management, Wind energy inverter.
Safety Information
This sensor must be used according to IEC61800-5-1 and applicable standards. Caution, risk of electrical shock! Hazardous voltages may be present on certain parts during operation. The sensor is a built-in device; conducting parts must be inaccessible after installation. A protective housing or additional shield is recommended. The main supply must be disconnectable.
Environmental and Mechanical Characteristics
| Parameter | Symbol | Unit | Min | Typ | Max | Comment |
| Ambient operating temperature | TA | -40 | 105 | |||
| Ambient storage temperature | TS | -40 | 105 | |||
| Mass | m | g | 57 | |||
| Insulation coordination: Rms voltage for AC insulation test @ 50Hz, 1min | Vd | kV | 3.6 | Reinforced insulation, according to IEC 61800-5-1, IEC 62109-1 CAT III, PD2 | ||
| Insulation coordination: Impulse withstand voltage 1.2/50s | VW | kV | 6.6 | Reinforced insulation, according to IEC 61800-5-1, IEC 62109-1 CAT III, PD2 | ||
| Insulation coordination: Clearance (pri.- sec.) | dCI | mm | 6.3 | According to IEC 60664-1 | ||
| Insulation coordination: Creepage distance (pri.- sec.) | dCp | mm | 7.3 | According to IEC 60664-1 | ||
| Insulation coordination: Plastic case | UL94-V0 | |||||
| Insulation coordination: Comparative tracking index | CTI | PLC | 3 |
2506121200_CHIPSENSE-HS1V-400-H03_C49164835.pdf