AN3V PB50 Series Current Sensor
The AN3V PB50 series are open-loop current sensors based on the Hall effect, designed for measuring DC, AC, and pulse currents. They feature isolation between the primary and secondary sides, with materials compliant to UL 94-V0. These sensors offer no insertion loss and operate with a +5V supply voltage, boasting a height of 8.7mm. They adhere to international standards including IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010, and UL 508.
Applications: AC variable frequency drives, servo drives, DC motor drives, uninterruptible power supplies (UPS), modular power supplies, switching mode power supplies (SMPS), busbars, and MPPT.
Product Attributes
- Brand: Chipsensor ()
- Certifications: UL 94-V0, IEC 60664-1:2020, IEC 61800-5-1:2022, IEC 62109-1:2010, UL 508
- Material: Primary current busbar: Tin-plated copper
- Insulation: Primary and secondary sides are insulated.
Technical Specifications
| Model | Primary Rated Current (RMS) (IPN) | Primary Current Measurement Range (IPM) | Supply Voltage (VC) | Current Consumption (IC) | Zero Point Output Voltage (VOE) | Accuracy @ IPN | Temperature Drift of Zero Point Output Voltage (TCVOE) | Gain Error Temperature Drift (TCG) | Non-linearity Error (L) % of IPN | Tracking Time @ 90% of IPN (tr) | Output Bandwidth (-3dB) (BW) | Output Noise (Vno) | |
| Unit | A | A | V | mA | mV | % of IPN | mV | % | % | s | kHz | mVRMS | |
| AN3V 10 PB50 | -10 to 10 | -25 to 25 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 9 | |
| AN3V 16 PB50 | -16 to 16 | -40 to 40 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 6 | |
| AN3V 20 PB50 | -20 to 20 | -50 to 50 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 5 | |
| AN3V 32 PB50 | -32 to 32 | -80 to 80 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 2 | |
| AN3V 40 PB50 | -40 to 40 | -100 to 100 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 2.7 | |
| AN3V 50 PB50 | -50 to 50 | -125 to 125 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 1.7 | |
| AN3V 80 PB50 | -80 to 80 | -200 to 200 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 1.4 | |
| AN3V 100 PB50 | -100 to 100 | -250 to 250 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 1.1 | |
| AN3V 120 PB50 | -120 to 120 | -300 to 300 | 4.5 to 5.5 | 6.5 to 11 | -5 to 5 | -1 | 0.4 to 6 | -1.6 to 1.6 | -0.5 | 2.5 | 250 | 0.9 |
Maximum Limits
| Parameter | Symbol | Unit | Value |
| Supply Voltage | VC | V | 6.5 |
| Primary Busbar Temperature | TB | 120 | |
| Electrostatic Discharge-HBM Mode | VESD | V | 8000 |
Environmental and Structural Characteristics
| Parameter | Symbol | Unit | Min | Typical | Max | Remarks |
| Operating Temperature | TA | -40 | 105 | |||
| Storage Temperature | TS | -40 | 105 | |||
| Mass | m | g | 3.35 |
Insulation Characteristics
| Parameter | Symbol | Unit | Value | Remarks |
| AC Isolation Withstand Voltage (RMS @ 50Hz, 1min) | Vd | kV | 4.3 | Refer to IEC 60664-1 |
| Impulse Withstand Voltage 1.2/50s | VW | kV | 8 | Refer to IEC 60664-1 |
| Creepage Distance (Between Primary and Secondary) | dCp | mm | >8 | |
| Clearance Distance (Between Primary and Secondary) | dCI | mm | >8 | |
| Housing Material | - | - | UL94-V0 |
2407171028_CHIPSENSE-AN3V-40-PB50_C25011973.pdf