Specifications
Reset Temperature:
85℃
Mfr. Part #:
F20B115051ZA0060
Package:
SIP-2
Key Attributes
Model Number: F20B115051ZA0060
Product Description

Product Overview

This product is a thermal motor protector, temperature limiter, and thermal cut-out designed for safeguarding motors, transformers, coils, and electronic components. It offers small dimensions, is shock and vibration tested, and features a leadframe version. The product is tested for audio and video applications according to EN 60065, providing reliable protection against over-temperature conditions. It is suitable for use in protection category I and II.

Product Attributes

  • Brand: Cantherm
  • Certifications: VDE / ENEC, UL, cUL, CQC
  • Approvals: EN 60730-1 / -2-9, UL File Number E46827, C22.2 No. 77 / C22.2 No. 24, GB14536.1-1998 / GB14536.10-1996
  • Testing: Shock and vibration tested (similar to EN 50155), Tested for audio, video applications (EN 60065)
  • Resistances: Tight against ordinary resins and lacquers
  • Degrees of Protection: IP00

Technical Specifications

Model / Feature Control Type Rated Current at 250 V (50/60 Hz) Switching Cycles (Rated Current) Max. Current at 250 V (Failure Condition) Switching Cycles (Max. Current) Temperature Rating (Ta) Tolerance (Standard) Contact Resistance (incl. 100mm wire) Hysteresis Dielectric Strength (Standard Insulation) Shock / Vibration Testing
F13A / E Normally Closed 2.0 A / 1.6 A 7,000 4.0 A 3,000 70 C ... 190 C 5 K < 50 m 30 K 15 K 2 kV 400 m/s sine half wave / 100 m/s 5 Hz ... 2,000 Hz sine
F20A / E Normally Closed 3.0 A / 2.5 A 10,000 5.0 A 3,000 70 C ... 185 C 5 K < 50 m 30 K 15 K 2 kV 400 m/s sine half wave / 100 m/s 5 Hz ... 2,000 Hz sine
F23A / E Normally Closed 3.0 A / 3.0 A 10,000 4.0 A 3,000 70 C ... 185 C 5 K < 50 m 30 K 15 K 2 kV 400 m/s sine half wave / 100 m/s 5 Hz ... 2,000 Hz sine
F20B / G Normally Open 2.0 A / 1.6 A 7,000 4.0 A 3,000 70 C ... 185 C 5 K < 50 m 30 K 15 K 2 kV 400 m/s sine half wave / 100 m/s 5 Hz ... 2,000 Hz sine
Leadframe Version Technical Data:
Cantherm Code Max. Operating Voltage Diameter Insulation Cross Section UL Style Temperature Color Lead Length Housing Grid Dimension Insulation Approvals
ACFA 300 V 1.57 mm AWG24 / 0.24 mm 3266/3398 150 C Black 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL
AEFC 300 V 1.80 mm AWG20 / 0.48 mm 3266/3398 150 C Yellow 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL
KCFA 600 V 1.2 mm AWG24 / 0.25 mm 10086 200 C Black 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL, CSA
KEFA 600 V 1.6 mm AWG20 / 0.50 mm 10086 200 C Black 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL, CSA
ASFA 300 V 1.65 mm AWG20 / 0.81 mm 3266/3398 150 C Black 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL
DCFB 300 V 1.21 mm AWG24 / 0.51 mm 1180 200 C White 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL
DEFB 300 V 1.51 mm AWG20 / 0.81 mm 1180 200 C White 6" PPS 5.08 None / Not Insulated / Potted VDE, UL, cUL
Note: Additional wires available upon request. Specific variations and details on request. AWG24 is recommended. At the Ta (upper and lower) limits the hysteresis could deviate. Different power rating for GB14536.1-1998 / GB14536.10-1996.