Specifications
Reset Temperature:
65℃
Mfr. Part #:
F20B095053600060
Package:
SIP-2
Key Attributes
Model Number: F20B095053600060
Product Description

Product Overview

The Cantherm Thermal Motor Protector, also known as a Temperature Limiter or Thermal Cut-out, is designed for reliable overcurrent and overtemperature protection in various electrical components. Its compact size, shock and vibration resistance, and suitability for audio/video applications make it ideal for motors, transformers, coils, and sensitive electronics. The protector offers a range of temperature ratings and current capacities, ensuring robust performance and extended component life.

Product Attributes

  • Brand: Cantherm (Div. of Microtherm International Cooperation)
  • Country of Origin: Canada (Marking example: C)
  • Certifications: VDE / ENEC, UL, cUL, CQC
  • Testing Standards: EN 60065, EN 50155, EN 60730-1 / -2-9, GB14536.1-1998 / GB14536.10-1996
  • Material: PPS housing, Aluminum housing (specific models)
  • Insulation Options: None, Potted, Coated, Shrink Cap, Cap of PPS
  • Leadframe Version: Available
  • Suitability: Protection category I, II

Technical Specifications

Feature F13A / E F20A / E F23A / E F20B / G
Control Type Normally Closed / Normally Open Normally Closed / Normally Open Normally Closed / Normally Open Normally Closed / Normally Open
Rated Current at 250 V 50/60 Hz (PF 0.95 / 0.6) 2.0 A / 1.6 A 3.0 A / 2.5 A 3.0 A / 3.0 A 2.0 A / 1.6 A
Switching Cycles under Rated Current 7,000 10,000 10,000 7,000
Max. Current under Failure Condition at 250 V 50/60 Hz (PF 0.95) 4.0 A 5.0 A 4.0 A -
Switching Cycles under Max. Current 3,000 3,000 3,000 3,000
Temperature Rating Ta (steps in 5 K) 70 C ... 190 C 70 C ... 185 C 70 C ... 185 C 70 C ... 190 C
Tolerances Standard: 5 K Standard: 5 K Standard: 5 K Standard: 5 K
Feature of Automatic Action 1.B, 2.B.M, 1.C 2.B, 1.C 2.B, 1.C 1.B, 2.B.M, 1.C
Contact Resistance (incl. wire of 100 mm) < 50 m < 50 m < 50 m < 50 m
Hysteresis 30 K 15 K 30 K 15 K 30 K 15 K 30 K 15 K
Dielectric Strength (standard insulation) 2 kV
Shock / Vibration Testing 400 m/s sine half wave / 100 m/s 5 Hz ... 2,000 Hz sine
Resistances to Impregnation Tight against ordinary resins and lacquers
Degrees of Protection Provided by Enclosures (EN 60529) IP00
UL File Number E46827 E46827 E46827 E46827
Approvals VDE, UL, cUL VDE, UL, cUL, CSA VDE, UL, cUL, CSA VDE, UL, cUL, CSA
Cantherm Lead Cantherm Code Max. Operating Voltage Max. Diameter Insulation Cross Section UL Style Temperature
Standard wire (length 100 10 mm, stripped 6 1 mm) - - - - - -
ACFA ACFA 300 V 1.57 mm AWG24 / 0.24 mm 3266/3398 150 C
AEFC AEFC 300 V 1.80 mm AWG20 / 0.48 mm 3266/3398 150 C
KCFA KCFA 600 V 1.2 mm AWG24 / 0.25 mm 10086 200 C
KEFA KEFA 600 V 1.6 mm AWG20 / 0.50 mm 10086 200 C
ASFA ASFA 300 V 1.65 mm AWG20 / 0.81 mm 3266/3398 150 C
DCFB DCFB 300 V 1.21 mm AWG24 / 0.51 mm 1180 200 C
DEFB DEFB 300 V 1.51 mm AWG20 / 0.81 mm 1180 200 C
Model Insulation Illustration Drawing Dimensions (mm) Approvals
F13 A None | 0 not insulated, potted - - VDE, UL, cUL
F20, F23 A None | 0 not insulated, potted A, B - VDE, UL, cUL, CSA
F20, F23 A U112 | L different dimensions for F20, F23 coated A, B - VDE, UL, cUL
F20, F23 A G410 | 6 Leads housing of PPS, potted A, B - VDE, UL, cUL, CSA
F13 A A150 | 36 U112 | L different dimensions for F20, F23 leadframe leads grid dimension 5.08, potted A, B - VDE, UL, cUL
F20, F23 A G700 | B alluminium housing thread M4x6 potted Ta max. 150 C E, G - VDE, UL, cUL, CSA
F13 A G410 | 6 Leads | ACFA housing of PPS potted A, B - VDE, UL, cUL
F13 F20, F23 A A150 | 36 U112 | L different dimensions for F20, F23 leadframe leads grid dimension 5.08 coated A, B - VDE, UL, cUL, CSA
F13 A U102 | B U106 | F different dimensions for F20, F23 shrink cap potted A - VDE, UL, cUL
F20, F23 A U198 different dimensions for F20, F23 cap of PPS potted B - VDE, UL, cUL
F20, F23 A U185 rent dimensions for F Heating by current B - -

Marking Example

F20A 120 05 L310 100 U254

  • Type: F20A (normally closed)
  • Response Temperature: 120C
  • Tolerance: 5K
  • Lead Wire: L310 (example)
  • Lead Length: 100 (mm)
  • Insulation: U254 (example)

Ordering Example

[ F20A12005ACFA06E ]

  • Type: F20A
  • Norm. Closed
  • Tolerance: +/-5C
  • Wire Leads: ACFA (UL3398 24 AWG)
  • Lead Length: 06 (6 inches)
  • Color: Black
  • Insulation: No insulation
  • Housing: G410
  • Strip: .25"
  • Marking: F20A type (F20 nc) 12005 response temperature (120C), tolerance ( 5K) 065C date of manufacture (June 2015), country (C = Canada)