Specifications
Mfr. Part #:
BSL-1000IOV2L
Key Attributes
Model Number: BSL-1000IOV2L
Product Description

BSL-IOV2L Current Sensors

The BSL-IOV2L series from BYD Microelectronics Co., Ltd. are Hall effect current sensors designed for the electronic measurement of DC, AC, pulsed, and mixed currents. They provide galvanic isolation between the primary and secondary circuits, offering low power consumption and an extended measuring range. These sensors are easy to install, compact, and feature a single design for a wide current ratings range, with high immunity to external interference.

Product Attributes

  • Brand: BYD Microelectronics Co., Ltd.
  • Origin: Not specified
  • Material: Not specified
  • Color: Not specified
  • Certifications: Not specified

Technical Specifications

TypePrimary nominal current r. m. s IPN (A)Primary current measuring range IP (A)Supply voltage (5%) VC (V)Current consumption IC (mA)Output voltage VOUT (V)Isolation resistance RIS (M)Load resistance RL (K)Linearity (0IPN) L (% of IPN)Accuracy X (% of IPN)Electrical offset voltage VOE (mV)Hysteresis offset voltage VOH (mV)Temperature coefficient of VOE (mV/K)Temperature coefficient of VOUT (%/K)Response time tr (S)Frequency bandwidth BW (kHz)Ambient operating temperature TA ()Ambient storage temperature TS ()Mass (g)Rated isolation voltage rms Vb (V)Rms voltage for AC isolation test Vd (kV)
BSL-200IOV2L20040015154 @ IPN, RL = 10 k, TA = 25C>1000 @ 500 VDC>10<1 @ IPN, TA = 25C<1 @ IPN, TA = 25C<20 @TA = 25C<10 @ IP= 0<1<0.1<5 @ 90% of IPNDC~25 @-3dB-20.+85-40.+10530010003 @50 Hz, 1 min
BSL-400IOV2L40080015154 @ IPN, RL = 10 k, TA = 25C>1000 @ 500 VDC>10<1 @ IPN, TA = 25C<1 @ IPN, TA = 25C<20 @TA = 25C<10 @ IP= 0<1<0.1<5 @ 90% of IPNDC~25 @-3dB-20.+85-40.+10530010003 @50 Hz, 1 min
BSL-600IOV2L600120015154 @ IPN, RL = 10 k, TA = 25C>1000 @ 500 VDC>10<1 @ IPN, TA = 25C<1 @ IPN, TA = 25C<20 @TA = 25C<10 @ IP= 0<1<0.1<5 @ 90% of IPNDC~25 @-3dB-20.+85-40.+10530010003 @50 Hz, 1 min
BSL-800IOV2L800160015154 @ IPN, RL = 10 k, TA = 25C>1000 @ 500 VDC>10<1 @ IPN, TA = 25C<1 @ IPN, TA = 25C<20 @TA = 25C<10 @ IP= 0<1<0.1<5 @ 90% of IPNDC~25 @-3dB-20.+85-40.+10530010003 @50 Hz, 1 min
BSL-1000IOV2L1000200015154 @ IPN, RL = 10 k, TA = 25C>1000 @ 500 VDC>10<1 @ IPN, TA = 25C<1 @ IPN, TA = 25C<20 @TA = 25C<10 @ IP= 0<1<0.1<5 @ 90% of IPNDC~25 @-3dB-20.+85-40.+10530010003 @50 Hz, 1 min
BSL-2000IOV2L2000300015154 @ IPN, RL = 10 k, TA = 25C>1000 @ 500 VDC>10<1 @ IPN, TA = 25C<1 @ IPN, TA = 25C<20 @TA = 25C<10 @ IP= 0<1<0.1<5 @ 90% of IPNDC~25 @-3dB-20.+85-40.+10530010003 @50 Hz, 1 min

Applications

Industrial applications include DC motor drives, Switched Mode Power Supplies (SMPS), AC variable speed drives, Uninterruptible Power Supplies (UPS), battery supplied applications, and power supplies for welding applications.

Instructions of Use

  • When test current passes through the sensors, the output voltage size can be obtained. (Warning: wrong connection may lead to sensors damage)
  • The sensors output range can be regulated based on user needs.