Product Overview
The 12 13B Thermal Motor Protector is a reliable temperature limiter and thermal cut-out designed for a wide range of applications including motors, transformers, coils, electronics, sensors, and process automation. It offers a high current rating of up to 30A and is non-sensitive to current, providing robust protection. The protector is available in manifold executions and a special low current version, ensuring versatility for various industrial needs.
Product Attributes
- Brand: Cantherm (Div. of Microtherm International Cooperation)
- Origin: Canada (Marking example indicates C = Canada)
- Certifications: VDE / ENEC, UL, CSA / cUL, CQC
- Protection Against: Overheating, thermal runaway
- Resistances: Tight against ordinary resins and lacquers
- Degrees of Protection (EN 60529): IP00
- Suitable for use in protection category: I, II
- Insulation Types: Standard, shrink cap, potted, coated, PPS housing, aluminum housing, brass housing
- Wire Insulation Colors (Examples): Black, Yellow, White
Technical Specifications
| Feature | Model / Version | Control Type | Rated Current (250V, 50/60Hz) | Switching Cycles (Rated Current) | Max. Current (250V, 50/60Hz) | Switching Cycles (Max. Current) | Temperature Rating (Ta) | Temperature Tolerance | Hysteresis | Contact Resistance | Dielectric Strength | Shock / Vibration Resistance | Max. Operating Voltage | Max. Diameter | Insulation Cross Section | UL Style |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Standard Wire | B12A / B | Normally Closed | 6.3 A / 6.0 A (cos 0.95 / 0.6) | 10,000 | 30.0 A (cos 0.95) | 100 | 70 C ... 190 C | 5 K (Standard) | 30 K 15 K 1) | < 50 m | 2 kV | 400 m/s sine half wave / 100 m/s 5 Hz ... 2.000 Hz sine | 300 V | 1.57 mm | AWG24 / 0.24 mm | 3266/3398 |
| Standard Wire | B12B / G | Normally Open | 10.0 A / 6.0 A (cos 0.95 / 0.6) | 5,000 | 30.0 A (cos 0.95) | 100 | 70 C ... 160 C | 5 K (Standard) | 30 K 15 K 1) | < 50 m | 2 kV | 400 m/s sine half wave / 100 m/s 5 Hz ... 2.000 Hz sine | 300 V | 1.80 mm | AWG20 / 0.48 mm | 3398 |
| Standard Wire | B13N / T | Normally Closed/Open | 13.0 A / 6.0 A (cos 0.95 / 0.6) | 1,000 | 30.0 A (cos 0.95) | 100 | 70 C ... 155 C | 5 K (Standard) | 30 K 15 K 1) | < 50 m | 2 kV | 400 m/s sine half wave / 100 m/s 5 Hz ... 2.000 Hz sine | 300 V | 2.15 mm | AWG18 / 0.96 mm | 3266/3398 |
| Special Low Current Version | Version Varies | Normally Closed | 1...100 mA (24 Vdc) | 10,000 | N/A | N/A | Varies (e.g., 70 C ... 160 C) | 5 K (Standard) | 30 K 15 K 1) | < 50 m | 2 kV | 400 m/s sine half wave / 100 m/s 5 Hz ... 2.000 Hz sine | 24 Vdc | Varies | Varies | N/A |
| Cantherm Lead | ACDA | N/A | N/A | N/A | N/A | N/A | 150 C | N/A | N/A | N/A | N/A | N/A | 300 V | 1.57 mm | AWG24 / 0.24 mm | 3266/3398 |
| Cantherm Lead | AEDC | N/A | N/A | N/A | N/A | N/A | 150 C | N/A | N/A | N/A | N/A | N/A | 300 V | 1.80 mm | AWG20 / 0.48 mm | 3398 |
| Cantherm Lead | AFDA | N/A | N/A | N/A | N/A | N/A | 150 C | N/A | N/A | N/A | N/A | N/A | 300 V | 2.15 mm | AWG18 / 0.96 mm | 3266/3398 |
| Cantherm Lead | LCDB | N/A | N/A | N/A | N/A | N/A | 200 C | N/A | N/A | N/A | N/A | N/A | 600 V | 0.90 mm | AWG24 / 0.24 mm | 3557 |
| Cantherm Lead | LEDB | N/A | N/A | N/A | N/A | N/A | 200 C | N/A | N/A | N/A | N/A | N/A | 600 V | 1.26 mm | AWG20 / 0.61 mm | N/A |
| Cantherm Lead | LFDB | N/A | N/A | N/A | N/A | N/A | 200 C | N/A | N/A | N/A | N/A | N/A | 600 V | 1.50 mm | AWG18 / 0.96 mm | N/A |
| Cantherm Lead | ASDA | N/A | N/A | N/A | N/A | N/A | 150 C | N/A | N/A | N/A | N/A | N/A | 300 V | 1.65 mm | AWG20 / 0.81 mm | 3266/3398 |
| Cantherm Lead | DEDB | N/A | N/A | N/A | N/A | N/A | 200 C | N/A | N/A | N/A | N/A | N/A | 300 V | 1.51 mm | AWG20 / 0.81 mm | 1180 |
| Housing | B12 / B13 with U103 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Class B |
| Housing | B12 / B13 with U107 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Class F |
| Housing | B12 / B13 with U155 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Shrink cap, potted |
| Housing | B12 / B13 with U186 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | PPS cap, potted |
| Housing | B12 / B13 with U112 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | None, not insulated, potted |
| Housing | B12 / B13 with U294 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Coated |
| Housing | B12 / B13 with G702 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | PPS housing, potted |
| Housing | B12 / B13 with G714 | N/A | N/A | N/A | N/A | N/A | 150 C | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Aluminum housing, thread M4x6, potted |
| Housing | B12 / B13 with G714 | N/A | N/A | N/A | N/A | N/A | 150 C | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Brass housing, thread M4x5, potted |
| Housing | B12 / B13 with IZA | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | Not insulated, potted |
| Wire Lead | A800 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | C | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | E | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | 0 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | L | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | G | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | F | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | I | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | C | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | 0 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
| Wire Lead | E | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
1) At Ta (upper and lower) limits the hysteresis could deviate, for Ta > 130C the hysteresis is 30K -15K/+30K.
2) Details on request.
Note: The diagram for self-heating is measured with a thermal control without any insulation in an oil bath. The heating depends on the thermal conduction of the control to the equipment or part which should be protected.
2410311312_Cantherm-B12B09505AEDA0GE_C17645353.pdf