Product Overview
The G-75 PTF30 Series Pressure Transmitters offer minimized disturbance effects through improved noise resistance and excellent corrosion resistance with a stainless steel housing. These high-accuracy transmitters boast a 0.3% F.S. accuracy and a wide range of functions including user input range, display scale, output scale, digital filter, multi-display selection, abnormal operation display, and TUF (Two Unit Function). They are suitable for applications such as indoor heating, water supply and sewage, and incinerators, particularly for small and medium-sized projects. The series features explosion-proof specifications (Ex D IIC T6) and IP67 protection structure (IEC standard).
Product Attributes
- Brand: Konics (implied by explosion-proof certification management)
- Housing Material: Stainless Steel
- Body Material: Aluminum (AlDc.8S)
- Diaphragm Material: Stainless Steel 316
- Connections Material: Stainless Steel 316
- O-Ring Material: Buna N
- Explosion-proof Specification: Ex D IIC T6
- Protection Structure: IP67 (IEC standard)
Technical Specifications
| Item | Description | Specification |
|---|---|---|
| Series | PTF30 Display Type Pressure Transmitters | |
| Measurement Pressure | Gauge pressure, sealed gauge pressure, Absolute pressure | |
| Rated Pressure Range (Examples) | Gauge Pressure: 0 to 35kPa, 0 to 0.1MPa, 0 to 0.2MPa, 0 to 0.7MPa, 0 to 2MPa, 0 to 3.5MPa, 0 to 7MPa, 0 to 21MPa, 0 to 35MPa | |
| Absolute Pressure: 0 to 35kPa, 0 to 0.1MPa, 0 to 0.2MPa, 0 to 0.7MPa, 0 to 2MPa, 0 to 3.5MPa | ||
| Sealed Gauge Pressure: -35 to 0kPa, -0.1 to 0MPa, -0.1 to 0.2MPa, -0.1 to 0.7MPa, -0.1 to 2MPa, -0.1 to 3.5MPa | ||
| HART Communication Output | None | |
| Mounting Bracket | Without bracket, With bracket | |
| Pressure Port | G3/8 (PF) | |
| Measured Materials | Vapor, liquid, fluid (except corrosive environment of stainless steel 316) | |
| Power Supply | 15-35VDC | |
| Display Method | 12-segment 4-digit LCD | |
| Display Character Size | W6.24H10.73mm (12-segment) / W1.45H2.5mm (unit) | |
| Output | DC4-20mA 2-wire | Low-limit: 3.6mA (-2.5%), high-limit: 21.6mA (+10%) |
| Accuracy | 0.3% of F.S. | |
| Temperature Characteristics | At 20, (0.075% URL + 0.15% Span) | |
| Setting Method | Setting by front push keys | |
| Sampling Cycle | 300ms | |
| Dielectric Resistance | 1,000VAC for 1 min (between external terminal and case) | |
| Vibration | 0.75mm amplitude at frequency of 5 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | |
| Insulation Resistance | Over 100M (at 500VDC megger) | |
| Noise Immunity | Square shaped noise by noise simulator (pulse width 1s) 240V | |
| Memory Protection | Approx. 10 years (non-volatile semiconductor memory type) | |
| Ambient Temperature | -20 to 70 | Storage: -20 to 80 |
| Ambient Humidity | 0 to 85%RH | |
| Unit Weight | Approx. 1.2kg | |
| Dimensions (approx.) | Height: 128mm, Diameter: 83mm | |
| Functions | User input range, Display scale, Output scale, Digital filter, Multi display selection, Abnormal operation display, TUF (Two Unit Function), Zero-point correction, Slope correction, Digital input, High/Low peak monitoring, Error Lock, Parameter initialization |