Online Service

Online Service

Contact Person
+86 136 6733 2386
quality pressure transmitter Autonics PTF30-G5NN-F8 with stainless steel diaphragm and explosion proof housing factory
<
quality pressure transmitter Autonics PTF30-G5NN-F8 with stainless steel diaphragm and explosion proof housing factory
>
Specifications
Pressure range:
0Kpa~1.96133Mpa
Mfr. Part #:
PTF30-G5NN-F8
Key Attributes
Model Number: PTF30-G5NN-F8
Product Description

Product Overview

The G-75 PTF30 Series Display Type Pressure Transmitters offer a robust solution for measuring pressure with minimized disturbance effects due to improved noise resistance. Featuring excellent corrosion resistance with a stainless steel housing and high accuracy of 0.3% F.S., these transmitters are designed for demanding industrial applications. They come equipped with a variety of functions including user input range, display scale, output scale, digital filter, multi-display selection, abnormal operation display, and Two Unit Function (TUF). The series also includes explosion-proof specifications (Ex D IIC T6) and IP67 protection structure, making them suitable for indoor heating, water supply and sewage, incinerator, and small to medium-sized projects.

Product Attributes

  • Brand: Konics (implied by explosion-proof certification management)
  • Housing Material: Stainless steel
  • Diaphragm Material: Stainless steel 316
  • Connection Material: Stainless steel 316
  • Body Material: Aluminum (AlDc.8S)
  • O-Ring Material: Buna N
  • Explosion-proof Specification: Ex D IIC T6
  • Protection Structure: IP67 (IEC standard)

Technical Specifications

Specification Details
Series PTF30
Measurement Type Gauge pressure, Sealed gauge pressure, Absolute pressure
Rated Pressure Range Options 0 to 35kPa, 0 to 0.1MPa, 0 to 0.2MPa, 0 to 0.7MPa, 0 to 2MPa, 0 to 3.5MPa, 0 to 7MPa, 0 to 21MPa, 0 to 35MPa, -35 to 0kPa, -0.1 to 0MPa, -0.1 to 0.2MPa, -0.1 to 0.7MPa, -0.1 to 2MPa, -0.1 to 3.5MPa
HART Communication Output None
Mounting Bracket Without bracket, With bracket
Pressure Port G3/8 (PF)
Measured Materials Vapor, liquid, fluid (except corrosive environment of stainless steel 316)
Power Supply 15-35VDC
Display Method 12-segment 4-digit LCD
Display Character Size W6.24H10.73mm (12-segment) / W1.45H2.5mm (unit)
Output DC4-20mA 2-wire (Low-limit: 3.6mA (-2.5%), High-limit: 21.6mA (+10%))
Accuracy 0.3% of F.S.
Temperature Characteristics At 20, (0.075% URL + 0.15% Span)
Setting Method Front push keys
Sampling Cycle 300ms
Dielectric Resistance 1,000VAC for 1 min (between external terminal and case)
Vibration Resistance 0.75mm amplitude at frequency of 5 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Insulation Resistance Over 100M (at 500VDC megger)
Noise Immunity Square shaped noise by noise simulator (pulse width 1s) 240V
Memory Protection Approx. 10 years (non-volatile semiconductor memory type)
Ambient Temperature -20 to 70 (Storage: -20 to 80)
Ambient Humidity 0 to 85%RH
Unit Weight Approx. 1.2kg
Dimensions (Main Body) 83mm, Height 200mm (approx.)
Functions Available User input range, Display scale, Output scale, Digital filter, Multi display selection, Abnormal operation display, TUF (Two Unit Function), Zero-point correction, Slope correction, Digital input, High/Low peak monitoring, Error Lock, Parameter initialization

2411220207_Autonics-PTF30-G5NN-F8_C6629903.pdf