Product Overview
The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for detecting smaller targets. High-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. Integrated self-diagnosis, mutual interference prevention, and external diagnosis functions enhance reliability and ease of maintenance. The sensor boasts an IP65 protection structure according to IEC standards, making it suitable for demanding industrial environments.
Product Attributes
- Brand: Autonics
- Product Series: BW Series
- Type: Area Sensor
- Sensing Method: Through-beam type
- Protection Structure: IP65 (IEC standard)
- Light Source: Infrared LED (850nm modulated)
- Case Material: Aluminum
- Front Cover/Sensing Part Material: Acrylic
- Cable Connector: M12
- Approvals:
Technical Specifications
| Model | Sensing Distance | Min. Sensing Target | Optical Axis Pitch | Number of Optical Axis | Sensing Height | Response Time | Power Supply | Current Consumption (Emitter/Receiver) | Operation Mode | Control Output | Protection Circuit | Insulation Resistance | Synchronization Type | Self-Diagnosis | Interference Protection | Noise Immunity | Dielectric Strength | Vibration | Shock | Ambient Illumination | Ambient Temperature | Ambient Humidity | Weight (BW20-48/BW40-24) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BW20-(P) | 0.1 to 7m | Opaque material of min. 30mm | 20mm | 8 to 48 | 140 to 940mm | Max. 10ms | 12-24VDC 10% (ripple P-P: max. 10%) | Emitter: max. 120mA, Receiver: max. 120mA | Light ON fixed | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | Reverse polarity protection circuit, output short over current protection circuit | Over 20M (at 500VDC megger) | Timing method by synchronous line | Emitter/Receiver monitoring, direct light monitoring, over current monitoring | Interference protection by master/slave function | 240V the square wave noise (pulse width 1) by the noise simulator | 1,000VAC 50/60Hz for 1 min | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | Ambient light: max. 100,000lx (receiver illumination) | -10 to 55, storage: -20 to 60 | 35 to 85%RH, storage: 35 to 85%RH | Approx. 2.1kg (approx. 1.4kg) |
| BW40-(P) | 0.1 to 7m | Opaque material of min. 50mm | 40mm | 4 to 24 | 120 to 920mm |
Ordering Information
Model Structure: BW [Optical Axis Pitch] [Number of Optical Axis] [Control Output]
- Optical Axis Pitch: 20 (20mm), 40 (40mm)
- Number of Optical Axis: 04 to 48
- Control Output: No mark (NPN open collector output), P (PNP open collector output)
Example: BW2008P (BW Series, 20mm optical axis pitch, 8 optical axes, PNP open collector output)
Dimensions
(Refer to attached diagrams for detailed dimensions of Emitter, Receiver, Bracket A, and Bracket B. Dimensions are provided in mm.)
Input/Output Circuit and Connections
Wiring Connection:
- Pin 1 (Brown): 12-24VDC
- Pin 2 (White): SYNC
- Pin 3 (Blue): 0V
- Pin 4 (Black): TEST (M/S)
Operation Indicator:
- Green LED: POWER (Stable light ON)
- Yellow LED: Unstable light ON
- Red LED: Stable light OFF
Control Output: NPN or PNP open collector output.
Functions
- Self-diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Control output turns OFF and operation indicator displays status upon error.
- Interference Protection: Master/Slave function to prevent sensing errors when multiple sensors are used in parallel.
- External Diagnosis: TEST input on the emitter stops light emission when set to 0V, allowing external systems to verify operation.
Proper Usage
- Follow instructions in 'Proper Usage' to prevent accidents.
- Use 12-24VDC power supply that is insulated and limited voltage/current or Class 2, SELV.
- Wait 1 second after supplying power before using the product. Supply power to the sensor first if using separate power supplies for sensor and load.
- For switching mode power supplies, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
- Remove surge with diodes or varistors when connecting DC relays or inductive loads.
- Keep wires short and away from high voltage or power lines to prevent surge and inductive noise.
- Suitable for indoor use (within specified environmental conditions), altitude max. 2,000m, pollution degree 2, installation category II.