Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Durable Autonics BW20-20P through beam photoelectric sensor with 20mm optical axis pitch and IP65 protection factory
<
quality Durable Autonics BW20-20P through beam photoelectric sensor with 20mm optical axis pitch and IP65 protection factory
>
Specifications
Mfr. Part #:
BW20-20P
Key Attributes
Model Number: BW20-20P
Product Description

Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for precise detection. High-brightness LEDs on both the emitter and receiver ensure easy recognition from side, front, and long distances. The sensor includes self-diagnosis, mutual interference prevention, and external diagnosis functions for reliable operation. Its robust IP65 protection structure makes it suitable for demanding industrial environments.

Product Attributes

  • Brand: Autonics
  • Product Series: BW Series
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Cable Type: 5mm, 4-wire, M12 connector
  • Approvals:

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption (Emitter/Receiver) Operation Mode Control Output Light Source Insulation Resistance Synchronization Type Protection Circuit Noise Immunity Dielectric Strength Vibration Shock Ambient Temperature Ambient Humidity Weight (Unit Only)
BW20- (P) Through-beam type 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Infrared LED (850nm modulated) Over 20M (at 500VDC megger) Timing method by synchronous line Reverse polarity protection circuit, output short over current protection circuit 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH Approx. 1.4kg
BW40- (P) Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm

Dimensions

BW20 Series (Optical Axis Pitch: 20mm)

Model L (Sensing Height) A, B (Bracket Size)
BW20-08(P)160mm20
BW20-12(P)240mm-
BW20-16(P)320mm-
BW20-20(P)400mm-
BW20-24(P)480mm-
BW20-28(P)560mm-
BW20-32(P)640mm-
BW20-36(P)720mm-
BW20-40(P)800mm-
BW20-44(P)880mm-
BW20-48(P)960mm-

BW40 Series (Optical Axis Pitch: 40mm)

Model L (Sensing Height) A, B (Bracket Size)
BW40-04(P)160mm40
BW40-06(P)240mm-
BW40-08(P)320mm-
BW40-10(P)400mm-
BW40-12(P)480mm-
BW40-14(P)560mm-
BW40-16(P)640mm-
BW40-18(P)720mm-
BW40-20(P)800mm-
BW40-22(P)880mm-
BW40-24(P)960mm-

Features

  • Long sensing distance up to 7m.
  • 22 types of products available (optical axis: 20/40mm, sensing height: 120 to 940mm).
  • Minimizes unsensing area with 20mm optical axis pitch (BW20- models).
  • High brightness LED on Emitter and Receiver for easy recognition from side, front, and long-distance.
  • Self-diagnosis function: Emitter/Receiver monitoring, direct light monitoring, over current monitoring.
  • Mutual interference prevention function (master/slave).
  • External diagnosis function: Emitting stops when TEST input (black) of emitter is 0V, allowing external system monitoring.
  • Protection structure IP65 (IEC standard).

Functions

  • Self-diagnosis: Monitors emitter, receiver, direct light, and over current.
  • Interference Protection: Master/slave function to prevent sensing errors from light interference when using multiple sensors.
  • External Diagnosis: TEST input on the emitter stops light emission, indicated by a flashing red LED, allowing external system checks.

Wiring and Connections

Input/Output Circuit and Connections

Pin No. Cable Color (Emitter) Cable Color (Receiver) Emitter Function Receiver Function
1BrownBrown12-24VDC12-24VDC
2WhiteWhiteSYNCSYNC
3BlueBlue0V0V
4BlackBlackTEST (M/S)OUT

Operation Indicator

LED Color Emitter Receiver Status
GreenPOWER-Stable light ON
Yellow-UnstableStable light ON
RedTEST (M/S)-Stable light OFF

Connecting Cables (Sold Separately)

Type Model Cable Length (L)
EmitterCID4-3T3m
CID4-5T5m
CID4-7T7m
CID4-10T10m
CID4-15T15m
ReceiverCID4-3R3m
CID4-5R5m
CID4-7R7m
CID4-10R10m
CID4-15R15m

Troubleshooting

Item Cause Troubleshooting
Not operating Power supply Supply the rated power.
Incorrect cable connection or disconnection Check the wiring.
Rated connection failure Use it within rated sensing distance.
Not operating sometimes Pollution by dirt of sensor cover Remove dirt by soft brush or cloth.
Connector connection failure Check the assembled part of the connector.
Control output is OFF even though there is no target object. Out of rated sensing distance Use within the rated sensing distance.
There is an obstacle to cut off the light emitted between emitter and receiver Remove the obstacle.
There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc. Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element Contact Autonics Corp.
LED displays for failure of emitter Break of light emitting circuit LED displays for failure of emitter
LED displays for failure of receiver Break of light emitting receiving element LED displays for failure of receiver
LED displays for synchronous line Synchronous line incorrect connection or disconnection Check the wiring.
Break of synchronous circuit of emitter or receiver Contact Autonics Corp.
LED displays for control output over current Control output line is shorten Check the wiring.
Over load Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction Treat after checking the emitter display LED.

Proper Usage

  1. Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
  2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  3. Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
  4. When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  5. When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  6. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
  7. This unit may be used in the following environments: Indoors (in the environment condition rated in 'Specifications') Altitude max. 2,000m Pollution degree 2 Installation category II.

2411220420_Autonics-BW20-20P_C17255219.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible