Compact, Digital Display Pressure Sensors - PSA/PSB Series
The PSA/PSB Series are compact, digital display pressure sensors designed for accurate and reliable pressure monitoring. Featuring a high-brightness red LED display, these sensors offer clear readings and versatile functionality. They are suitable for a wide range of applications involving air and non-corrosive gases, providing features like selectable response times for chattering prevention, easy one-touch connector types for maintenance, and built-in protection circuits for reverse power polarity and overcurrent. The series offers both PSA and PSB models with different connector and pressure port options, ensuring flexibility for various installation requirements.
Product Attributes
- Brand: G-35 / G-36 (Implied from document headers)
- Product Line: PSA / PSB Series
- Display Type: Digital, High brightness red LED (9.5mm height)
- Protection Structure: IP40 (IEC standard)
Technical Specifications
| Feature | PSA Series | PSB Series | PSB-C Series |
|---|---|---|---|
| Sensor Type | Pressure Sensor | Pressure Sensor | Pressure Sensor |
| Connector Type | Compact, Digital Display | Compact, Digital Display | Connector type |
| Pressure Port Types | Rc1/8 (Standard), NPT1/8 (Option) | M5 | M5 |
| Pressure Units Available | kPa, kgf/cm, bar, psi, mmHg, mmHO, inHg | kPa, kgf/cm, bar, psi | kPa, kgf/cm, bar, psi |
| Pressure Ranges (Examples) | Negative: 0.0 to -101.3 kPa Standard: 0.0 to 100.0 kPa Compound: -100.0 to 100.0 kPa | Negative: 5.0 to -101.3 kPa Standard: -5.0 to 110.0 kPa Compound: -101.2 to 110.0 kPa | Negative: 5.0 to -101.3 kPa Standard: -5.0 to 110.0 kPa Compound: -101.2 to 110.0 kPa |
| Output Types | NPN Open Collector, PNP Open Collector, Analog Voltage (1-5VDC) | NPN Open Collector, PNP Open Collector, Analog Voltage (1-5VDC) | NPN Open Collector, PNP Open Collector, Analog Voltage (1-5VDC) |
| Power Supply | 12-24VDC 10% (ripple P-P: Max. 10%) | ||
| Current Consumption | Max. 50mA | ||
| Control Output Load Voltage | Max. 30VDC | ||
| Control Output Load Current | Max. 100mA | ||
| Response Time | Selectable: 2.5ms, 5ms, 100ms, 500ms | ||
| Analog Output | 1-5VDC 2% F.S. | ||
| Display Accuracy | 0 to 50: Max. 1% F.S., -10 to 0: Max. 2% F.S. | ||
| Ambient Temperature | -10 to 50 | ||
| Ambient Humidity | 35 to 85%RH | ||
| Weight | Approx. 200g (120g unit only) | Approx. 160g (70g unit only) | Approx. 160g (70g unit only) |
| Material | Front/Rear Case: Polycarbonate (insert glass), Pressure port: die-cast (Zn) | Case, Pressure port, Cover: IXEF | Case, Pressure port, Cover: IXEF |
Ordering Information Examples
PSA Series:
- PS (Pressure Sensor) - 01 (100kPa) - C (Compound pressure) - P (PNP output) - Rc1/8 (Pressure port)
- PS (Pressure Sensor) - V01 (Negative pressure) - P (PNP output) - Rc1/8 (Pressure port)
PSB Series:
- PSB (Pressure Sensor) - 01 (100kPa) - C (Compound pressure) - P (PNP output) - M5 (Pressure port)
- PSB (Pressure Sensor) - V01 (Negative pressure) - P (PNP output) - M5 (Pressure port)
Note: Pressure port type is indicated by the suffix (e.g., Rc1/8, NPT1/8, M5).
Key Features
- High brightness red LED display (9.5mm height).
- Min. display interval: 0.1kPa (Negative/Standard Pressure), 0.2kPa (Compound Pressure).
- Convertible pressure units.
- Various output modes: Hysteresis, Automatic sensitivity, Independent 2 output, Window comparative.
- Chattering prevention for output (selectable response time: 2.5ms, 5ms, 100ms, 500ms).
- One-touch connector type for easy wiring and maintenance.
- Analog output: voltage (1-5VDC).
- Reverse power polarity and overcurrent protection circuit.
- Zero-point adjustment function, peak value monitoring, and bottom hold display.
Installation and Usage Notes
- Suitable for Air, Non-corrosive gas.
- Do not use with flammable gas as it is not an explosion-proof structure.
- Ensure wiring is done with power off.
- PSA Series: Two bracket types (sold separately) for flexible installation. Pressure port: Rc1/8 (standard), NPT1/8 (option).
- PSB Series: Pressure port is M5. Use general one-touch fitting.
- Tightening torque for fittings should not exceed specified limits to prevent mechanical issues.
- After power supply, it takes 3 seconds to operate.
Error Displays
- ER1: External pressure input during zero point adjustment.
- ER2: Overload applied on control output.
- ER3: Setting value does not match setting conditions.
- HHH: Applied pressure exceeds High-limit of display range.
- LLL: Applied pressure exceeds Low-limit of display range.