Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, while high-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. This sensor includes essential functions such as self-diagnosis, mutual interference prevention, and external diagnosis, and boasts an IP65 protection structure for robust environmental resistance.

Product Attributes

  • Brand: Autonics
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Approvals:

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Operation Mode Control Output Protection Circuit Insulation Resistance Synchronization Type Interference Protection Noise Immunity Dielectric Strength Vibration Shock Ambient Illumination Ambient Temperature Ambient Humidity Cable Accessory Weight (Unit Only)
BW20-(P) / BW40-(P) Through-beam type 0.1 to 7m BW20: Opaque material of min. 30mm
BW40: Opaque material of min. 50mm
BW20: 20mm
BW40: 40mm
BW20: 8 to 48
BW40: 4 to 24
BW20: 140 to 940mm
BW40: 120 to 920mm
Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output
Load voltage: max. 30VDC
Load current: max. 100mA
Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC
Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Bracket A: 4, Bracket B: 4, Bolt : 8 Approx. 1.4kg
BW20-48(P) - - - 20mm 48 940mm - - - - - - - - - - - - - - - - - - Approx. 1.4kg
BW40-24(P) - - - 40mm 24 920mm - - - - - - - - - - - - - - - - - - Approx. 1.4kg

Ordering Information

Item Optical axis pitch Number of optical axis Control output
BW 20mm (20) / 40mm (40) 04 to 48 No mark: NPN open collector output
P: PNP open collector output

Dimensions

Emitter/Receiver Dimensions:

Model L (mm) A (mm) B (mm)
BW20-08(P)1602026.6
BW40-04(P)1604028.6
BW20-12(P)2402022.6
BW40-06(P)2404028.6
BW20-16(P)3202022.6
BW40-08(P)3204028.6
BW20-20(P)4002022.6
BW40-10(P)4004028.6
BW20-24(P)4802022.6
BW40-12(P)4804028.6
BW20-28(P)5602022.6
BW40-14(P)5604028.6
BW20-32(P)6402022.6
BW40-16(P)6404028.6
BW20-36(P)7202022.6
BW40-18(P)7204028.6
BW20-40(P)8002022.6
BW40-20(P)8004028.6
BW20-44(P)8802022.6
BW40-22(P)8804028.6
BW20-48(P)9602022.6
BW40-24(P)9604028.6

(Refer to original document for visual diagrams of dimensions, brackets, and operation indicators)

Input/Output Circuit and Connections

Wiring Connection:

Pin No. Cable color (Emitter) Emitter Cable color (Receiver) Receiver
1 Brown 12-24VDC Brown 12-24VDC
2 White SYNC White SYNC
3 Blue 0V Blue 0V
4 Black TEST (M/S) Black OUT

Operation Indicator:

LED Color Emitter Receiver
Green POWER Stable light ON
Yellow - Unstable
Red TEST (M/S) Stable light OFF

Functions

  • Self-diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Control output turns OFF and operation indicator displays status upon error.
  • Interference Protection: Master/slave function to prevent sensing errors when using multiple sensors in parallel.
  • External Diagnosis: When TEST input (black) of emitter is 0V, emitting stops, and the red LED of the emitter flashes, allowing external systems to verify sensor operation.

Troubleshooting

Cause Troubleshooting
Not operating
  • Power supply: Supply the rated power.
  • Incorrect cable connection or disconnection: Check the wiring.
  • Rated connection failure: Use it within the rated sensing distance.
Not operating sometimes
  • Pollution by dirt of sensor cover: Remove dirt by soft brush or cloth.
  • Connector connection failure: Check the assembled part of the connector.
Control output is OFF even though there is no target object.
  • Out of rated sensing distance: Use within the rated sensing distance.
  • There is an obstacle to cut off the light emitted between emitter and receiver: Remove the obstacle.
  • There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc.: Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element
LED displays for failure of emitter Break of light emitting circuit
LED displays for failure of receiver Break of light receiving element
LED displays for synchronous line Synchronous line incorrect connection or disconnection: Check the wiring. Break of synchronous circuit of emitter or receiver.
LED displays for control output over current
  • Control output line is shorten: Check the wiring.
  • Over load: Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction: Treat after checking the emitter display LED.

Proper Usage

  1. Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
  2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  3. Use the product 1 second after supplying power. When using a separate power supply for the sensor and load, supply power to the sensor first.
  4. When using a switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  5. When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  6. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
  7. This unit may be used in the following environments:
    Indoors (in the environment condition rated in 'Specifications')
    Altitude max. 2,000m
    Pollution degree 2
    Installation category II

2411220420_Autonics-BW20-24_C17202894.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max