Product Overview
The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for precise detection. High-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. The sensor includes advanced functions such as self-diagnosis, mutual interference prevention, and external diagnosis, along with an IP65 protection structure for robust operation in demanding environments. It is suitable for applications requiring reliable detection of opaque objects.
Product Attributes
- Brand: Autonics (implied by document structure and contact information)
- Product Series: BW Series
- Protection Structure: IP65 (IEC standard)
- Light Source: Infrared LED (850nm modulated)
- Case Material: Aluminum
- Front Cover/Sensing Part Material: Acrylic
- Cable: 5mm, 4-wire, 300mm, M12 connector
- Approvals: Not explicitly stated beyond IP65
Technical Specifications
| Model | BW20- (P) | BW40- (P) |
|---|---|---|
| Sensing Method | Through-beam type | |
| Sensing Distance | 0.1 to 7m | |
| Min. Sensing Target | Opaque material of min. 30mm | Opaque material of min. 50mm |
| Optical Axis Pitch | 20mm | 40mm |
| Number of Optical Axis | 8 to 48 | 4 to 24 |
| Sensing Height | 140 to 940mm | 120 to 920mm |
| Response Time | Max. 10ms | |
| Power Supply | 12-24VDC 10% (ripple P-P: max. 10%) | |
| Current Consumption | Emitter: max. 120mA, Receiver: max. 120mA | |
| Operation Mode | Light ON fixed | |
| Control Output | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | |
| Protection Circuit | Reverse polarity protection circuit, output short over current protection circuit | |
| Insulation Resistance | Over 20M (at 500VDC megger) | |
| Synchronization Type | Timing method by synchronous line | |
| Self-Diagnosis | Emitter/Receiver monitoring, direct light monitoring, over current monitoring | |
| Interference Protection | Interference protection by master/slave function | |
| Noise Immunity | 240V the square wave noise (pulse width 1) by the noise simulator | |
| Dielectric Strength | 1,000VAC 50/60Hz for 1 min | |
| Vibration | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | |
| Shock | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | |
| Ambient Illumination | Ambient light: max. 100,000lx (receiver illumination) | |
| Ambient Temperature | -10 to 55, storage: -20 to 60 | |
| Ambient Humidity | 35 to 85%RH, storage: 35 to 85%RH | |
| Weight (approx.) | BW20-48: 2.1kg (1.4kg unit only) | BW40-24: 2.1kg (1.4kg unit only) |
Ordering Information
| Item | Optical Axis Pitch | Number of Optical Axis | Control Output |
|---|---|---|---|
| BW | 20mm (20) / 40mm (40) | 04 to 48 | NPN open collector output (No mark) / PNP open collector output (P) |
Dimensions
BW20 Series (Optical Axis Pitch: 20mm)
| Model | L (mm) | A, B (mm) |
|---|---|---|
| BW20-08(P) | 160 | 20 |
| BW20-12(P) | 240 | - |
| BW20-16(P) | 320 | - |
| BW20-20(P) | 400 | - |
| BW20-24(P) | 480 | - |
| BW20-28(P) | 560 | - |
| BW20-32(P) | 640 | - |
| BW20-36(P) | 720 | - |
| BW20-40(P) | 800 | - |
| BW20-44(P) | 880 | - |
| BW20-48(P) | 960 | - |
BW40 Series (Optical Axis Pitch: 40mm)
| Model | L (mm) | A, B (mm) |
|---|---|---|
| BW40-04(P) | 160 | 40 |
| BW40-06(P) | 240 | - |
| BW40-08(P) | 320 | - |
| BW40-10(P) | 400 | - |
| BW40-12(P) | 480 | - |
| BW40-14(P) | 560 | - |
| BW40-16(P) | 640 | - |
| BW40-18(P) | 720 | - |
| BW40-20(P) | 800 | - |
| BW40-22(P) | 880 | - |
| BW40-24(P) | 960 | - |
Note: Dimensions for Bracket A and Bracket B are provided in diagrams within the source document.
Features & Functions
- Long sensing distance up to 7m.
- Minimizes unsensing area with 20mm optical axis pitch (BW20- models).
- High brightness LED for easy recognition from side, front, and long-distance.
- Self-diagnosis function: Emitter/Receiver monitoring, direct light monitoring, over current monitoring.
- Mutual interference prevention function (master/slave operation).
- External diagnosis function (TEST input).
- Protection structure: IP65 (IEC standard).
- Operation mode: Light ON fixed.
- Control output: NPN or PNP open collector output.
- Protection circuits: Reverse polarity protection, output short over current protection.
Wiring & Connections
Input/Output Circuit and Connections
| Pin No. | Cable Color (Emitter/Receiver) | Emitter Function | Receiver Function |
|---|---|---|---|
| 1 | Brown | 12-24VDC | 12-24VDC |
| 2 | White | SYNC | SYNC |
| 3 | Blue | 0V | 0V |
| 4 | Black | TEST (M/S) | OUT |
Operation Indicator:
| LED Color | Emitter | Receiver |
|---|---|---|
| Green | POWER | Stable light ON |
| Yellow | - | Unstable |
| Red | TEST (M/S) | Stable light OFF |
Connecting Cables (Sold Separately):
| Type | Cable Length (L) |
|---|---|
| CID4-3T / CID4-3R | 3m |
| CID4-5T / CID4-5R | 5m |
| CID4-7T / CID4-7R | 7m |
| CID4-10T / CID4-10R | 10m |
| CID4-15T / CID4-15R | 15m |
Note: Separate cables are required for emitter and receiver.
Troubleshooting
| Cause | Troubleshooting |
|---|---|
| Not operating |
|
| Not operating sometimes |
|
| Control output is OFF even though there is no target object. |
|
| LED displays for break of light emitting element | Break of light emitting element |
| LED displays for failure of emitter | Break of light emitting circuit |
| LED displays for failure of receiver | Break of light receiving element |
| LED displays for synchronous line | Synchronous line incorrect connection or disconnection: Check the wiring. Break of synchronous circuit of emitter or receiver. |
| LED displays for control output over current |
|
| LED displays for emitter malfunction | Emitter malfunction: Treat after checking the emitter display LED. |
Proper Usage
- Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
- 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
- Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
- When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
- When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
- Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
- This unit may be used in the following environments: Indoors (in the environment condition rated in 'Specifications') Altitude max. 2,000m Pollution degree 2 Installation category II.