quality Durable photoelectric sensor with self diagnosis function Autonics BW40-16P and ip65 rated housing factory
<
quality Durable photoelectric sensor with self diagnosis function Autonics BW40-16P and ip65 rated housing factory
>
Specifications
Mfr. Part #:
BW40-16P
Key Attributes
Model Number: BW40-16P
Product Description

Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for precise detection. High-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. The sensor includes advanced functions such as self-diagnosis, mutual interference prevention, and external diagnosis, along with an IP65 protection structure for robust operation in demanding environments. It is suitable for applications requiring reliable detection of opaque objects.

Product Attributes

  • Brand: Autonics (implied by document structure and contact information)
  • Product Series: BW Series
  • Protection Structure: IP65 (IEC standard)
  • Light Source: Infrared LED (850nm modulated)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Cable: 5mm, 4-wire, 300mm, M12 connector
  • Approvals: Not explicitly stated beyond IP65

Technical Specifications

Model BW20- (P) BW40- (P)
Sensing Method Through-beam type
Sensing Distance 0.1 to 7m
Min. Sensing Target Opaque material of min. 30mm Opaque material of min. 50mm
Optical Axis Pitch 20mm 40mm
Number of Optical Axis 8 to 48 4 to 24
Sensing Height 140 to 940mm 120 to 920mm
Response Time Max. 10ms
Power Supply 12-24VDC 10% (ripple P-P: max. 10%)
Current Consumption Emitter: max. 120mA, Receiver: max. 120mA
Operation Mode Light ON fixed
Control Output NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC
Protection Circuit Reverse polarity protection circuit, output short over current protection circuit
Insulation Resistance Over 20M (at 500VDC megger)
Synchronization Type Timing method by synchronous line
Self-Diagnosis Emitter/Receiver monitoring, direct light monitoring, over current monitoring
Interference Protection Interference protection by master/slave function
Noise Immunity 240V the square wave noise (pulse width 1) by the noise simulator
Dielectric Strength 1,000VAC 50/60Hz for 1 min
Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s (approx. 50G) in each X, Y, Z direction for 3 times
Ambient Illumination Ambient light: max. 100,000lx (receiver illumination)
Ambient Temperature -10 to 55, storage: -20 to 60
Ambient Humidity 35 to 85%RH, storage: 35 to 85%RH
Weight (approx.) BW20-48: 2.1kg (1.4kg unit only) BW40-24: 2.1kg (1.4kg unit only)

Ordering Information

Item Optical Axis Pitch Number of Optical Axis Control Output
BW 20mm (20) / 40mm (40) 04 to 48 NPN open collector output (No mark) / PNP open collector output (P)

Dimensions

BW20 Series (Optical Axis Pitch: 20mm)

Model L (mm) A, B (mm)
BW20-08(P)16020
BW20-12(P)240-
BW20-16(P)320-
BW20-20(P)400-
BW20-24(P)480-
BW20-28(P)560-
BW20-32(P)640-
BW20-36(P)720-
BW20-40(P)800-
BW20-44(P)880-
BW20-48(P)960-

BW40 Series (Optical Axis Pitch: 40mm)

Model L (mm) A, B (mm)
BW40-04(P)16040
BW40-06(P)240-
BW40-08(P)320-
BW40-10(P)400-
BW40-12(P)480-
BW40-14(P)560-
BW40-16(P)640-
BW40-18(P)720-
BW40-20(P)800-
BW40-22(P)880-
BW40-24(P)960-

Note: Dimensions for Bracket A and Bracket B are provided in diagrams within the source document.

Features & Functions

  • Long sensing distance up to 7m.
  • Minimizes unsensing area with 20mm optical axis pitch (BW20- models).
  • High brightness LED for easy recognition from side, front, and long-distance.
  • Self-diagnosis function: Emitter/Receiver monitoring, direct light monitoring, over current monitoring.
  • Mutual interference prevention function (master/slave operation).
  • External diagnosis function (TEST input).
  • Protection structure: IP65 (IEC standard).
  • Operation mode: Light ON fixed.
  • Control output: NPN or PNP open collector output.
  • Protection circuits: Reverse polarity protection, output short over current protection.

Wiring & Connections

Input/Output Circuit and Connections

Pin No. Cable Color (Emitter/Receiver) Emitter Function Receiver Function
1Brown12-24VDC12-24VDC
2WhiteSYNCSYNC
3Blue0V0V
4BlackTEST (M/S)OUT

Operation Indicator:

LED Color Emitter Receiver
GreenPOWERStable light ON
Yellow-Unstable
RedTEST (M/S)Stable light OFF

Connecting Cables (Sold Separately):

Type Cable Length (L)
CID4-3T / CID4-3R3m
CID4-5T / CID4-5R5m
CID4-7T / CID4-7R7m
CID4-10T / CID4-10R10m
CID4-15T / CID4-15R15m

Note: Separate cables are required for emitter and receiver.

Troubleshooting

Cause Troubleshooting
Not operating
  • Power supply: Supply the rated power.
  • Incorrect cable connection or disconnection: Check the wiring.
  • Rated connection failure: Use it within rated sensing distance.
Not operating sometimes
  • Pollution by dirt of sensor cover: Remove dirt by soft brush or cloth.
  • Connector connection failure: Check the assembled part of the connector.
Control output is OFF even though there is no target object.
  • Out of rated sensing distance: Use within the rated sensing distance.
  • There is an obstacle to cut off the light emitted between emitter and receiver: Remove the obstacle.
  • There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc.: Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element
LED displays for failure of emitter Break of light emitting circuit
LED displays for failure of receiver Break of light receiving element
LED displays for synchronous line Synchronous line incorrect connection or disconnection: Check the wiring. Break of synchronous circuit of emitter or receiver.
LED displays for control output over current
  • Control output line is shorten: Check the wiring.
  • Over load: Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction: Treat after checking the emitter display LED.

Proper Usage

  • Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
  • 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
  • When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  • When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  • Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
  • This unit may be used in the following environments: Indoors (in the environment condition rated in 'Specifications') Altitude max. 2,000m Pollution degree 2 Installation category II.