Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Obstacle detection sensor Autonics BWC40-12HD featuring self diagnosis function and robust protection factory
<
quality Obstacle detection sensor Autonics BWC40-12HD featuring self diagnosis function and robust protection factory
>
Specifications
Mfr. Part #:
BWC40-12HD
Key Attributes
Model Number: BWC40-12HD
Product Description

Product Overview

The BWC Series Cross-Beam Area Sensor is designed for precise obstacle detection with a minimized blind zone achieved through a 3-point cross-beam netting method. It offers a long sensing distance of 1 to 7 meters and a wide range of model choices, varying in the number of optical axes (4 to 20), pitch of optical axes (40mm or 80mm), and sensing width (120mm to 1,040mm). Key features include built-in interference protection, a self-diagnosis function that monitors front screen contamination and optical axis obstruction, and conspicuous high-luminance indicators for easy status checks. This sensor is suitable for various applications, including obstacle detecting sensors for subway platform screen doors (PSD), and meets KRS Korean Railway Standards for specific models. The robust IP67 protection structure ensures reliability in diverse environments.

Product Attributes

  • Brand: BWC Series
  • Protection Structure: IP67 (IEC standard)
  • Certifications: KRS SG 0068 Approval
  • Material: Case: Aluminum, Sensing part and indicator: Acrylic
  • Cable: 5mm, 4-wire, 300mm, M12 connector

Technical Specifications

Model BWC40-H / HD BWC80-14H / HD
Sensing type Through-beam type
Sensing distance 1.0 to 7.0m
Sensing target Opaque material of min. 50mm Opaque material of min. 90mm
Optical axis pitch 40mm 80mm
Number of optical axes 4/10/12/16/18/20 14
Sensing height 120 to 760mm 1,040mm
Beam pattern 3-point cross-beam netting type
Response time Max. 50ms
Power supply 12-24VDC 10% (ripple P-P: max. 10%)
Current consumption Max. 100mA
Light source Infrared LED (850nm modulated)
Operation mode Light ON / Dark ON Light ON / Dark ON
Control output NPN open collector output Load voltage: max. 30VDC Load current: max. 100mA (self-diagnosis output: max 50mA) Residual voltage: max. 1VDC
Protection circuit Reverse power polarity, output short over current protection circuit
Insulation resistance Over 20M (at 500VDC megger)
Synchronization type Timing method by synchronous cable
Self-diagnosis Transmitted-received light monitoring, direct light monitoring, output circuit monitoring, self-diagnosis output (checking whether there is contamination on the front screen, or any obstacle on optical axis)
Interference protection Interference protection by frequency changing setting
Noise immunity 240V the square wave noise (pulse width: 1) by the noise simulation
Dielectric strength 1,000VAC 50/60Hz for 1 min
Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s (approx. 50G) in each X, Y, Z direction for 3 times
Environment: Ambient illumination Ambient light: max. 100,000lx (received light side illumination)
Environment: Ambient temperature -10 to 55, storage: -20 to 60
Environment: Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Weight (approx.) 2.1kg (approx. 1.7kg) (based on BWC80-14H, includes packaging)
Connection Cable (sold separately) CID4-3T/5T/7T/10T/15T (Emitter), CID4-3R/5R/7R/10R/15R (Receiver)

Model Number Breakdown:

  • BWC40-04H/HD: 4 optical axes, 120mm sensing height, 40mm pitch
  • BWC40-10H/HD: 10 optical axes, 360mm sensing height, 40mm pitch
  • BWC40-12H/HD: 12 optical axes, 440mm sensing height, 40mm pitch
  • BWC40-16H/HD: 16 optical axes, 600mm sensing height, 40mm pitch
  • BWC40-18H/HD: 18 optical axes, 680mm sensing height, 40mm pitch
  • BWC40-20H/HD: 20 optical axes, 760mm sensing height, 40mm pitch
  • BWC80-14H/HD: 14 optical axes, 1,040mm sensing height, 80mm pitch

Dimensions (mm):

Model L A, B
BWC40-04H/HD 160 40
BWC40-10H/HD 400 40
BWC40-12H/HD 480 40
BWC40-16H/HD 640 40
BWC40-18H/HD 720 40
BWC40-20H/HD 800 40
BWC80-14H/HD 1120 80

Wiring Connection:

Pin No Cable Color (Emitter) Emitter Cable Color (Receiver) Receiver
1 Brown 12-24VDC Brown 12-24VDC
2 White Sync White Sync
3 Blue 0V Blue 0V
4 Black MODE (OUT) Black OUT

Operation Indicator:

Indicator Color Status Meaning
Emitter Operation Indicator Green ON Stable light ON
Yellow ON Unstable area
Red ON Stable light OFF
Receiver Operation Indicator Green ON Stable light ON
Red ON Stable light OFF

Self-Diagnosis Output:

Condition Emitter Operation Indicator Control Output Self-Diagnosis Output
Front screen contamination level 1 Red, flashing at 1 sec interval OFF OFF
Front screen contamination level 2, covering optical axis Red, flashing at 0.25 sec interval ON ON

Interference Protection: Installation mode allows changing transmitted light frequency to prevent interference. Enter installation mode by supplying power with 0V to terminal 4 (black) MODE of the Emitter.


2411220421_Autonics-BWC40-12HD_C17290189.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max