Product Overview
The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch (BW20-) minimizes unsensing areas. High-brightness LEDs on both the emitter and receiver ensure easy recognition from side, front, and long distances. The sensor includes self-diagnosis, mutual interference prevention, and external diagnosis functions, along with an IP65 protection structure.
Product Attributes
- Brand: Autonics
- Product Series: BW Series
- Type: Area Sensor
- Sensing Method: Through-beam type
- Protection Structure: IP65 (IEC standard)
- Light Source: Infrared LED (850nm modulated)
- Material: Case: aluminum; Front cover, sensing part: acrylic
- Cable: 5mm, 4-wire, 300mm, M12 connector
- Approvals:
Technical Specifications
| Model | Sensing Distance | Min. Sensing Target | Optical Axis Pitch | Number of Optical Axis | Sensing Height | Response Time | Power Supply | Current Consumption | Operation Mode | Control Output | Protection Circuit | Insulation Resistance | Synchronization Type | Self-Diagnosis | Interference Protection | Noise Immunity | Dielectric Strength | Vibration | Shock | Ambient Temperature | Ambient Humidity | Weight (BW20-48/BW40-24) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BW20- (P) | 0.1 to 7m | Opaque material of min. 30mm | 20mm | 8 to 48 | 140 to 940mm | Max. 10ms | 12-24VDC 10% (ripple P-P: max. 10%) | Emitter: max. 120mA, Receiver: max. 120mA | Light ON fixed | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | Reverse polarity protection circuit, output short over current protection circuit | Over 20M (at 500VDC megger) | Timing method by synchronous line | Emitter/Receiver monitoring, direct light monitoring, over current monitoring | Interference protection by master/slave function | 240V the square wave noise (pulse width 1) by the noise simulator | 1,000VAC 50/60Hz for 1 min | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | 500m/s 2 (approx. 50G) in each X, Y, Z direction for 3 times | -10 to 55, storage: -20 to 60 | 35 to 85%RH, storage: 35 to 85%RH | Approx. 2.1kg (approx. 1.4kg) |
| BW40- (P) | 0.1 to 7m | Opaque material of min. 50mm | 40mm | 4 to 24 | 120 to 920mm |
Ordering Information
| Item | Description | Options |
|---|---|---|
| Optical axis pitch | 20mm | BW20- |
| Optical axis pitch | 40mm | BW40- |
| Number of optical axis | 04 to 48 | (P) for PNP open collector output |
| Control output | NPN open collector output | No mark |
Product Features
- Long sensing distance up to 7m.
- 22 types of products available with varying optical axis pitches (20/40mm) and sensing heights (120 to 940mm).
- Minimizes unsensing area with 20mm optical axis pitch (BW20- models).
- High brightness LED on Emitter and Receiver for easy recognition from side, front, and long-distance.
- Includes self-diagnosis, mutual interference prevention, and external diagnosis functions.
- Protection structure IP65 (IEC standard).
- Operation mode: Light ON fixed.
Dimensions
(Diagrams and specific model dimensions are not fully extractable into text format without visual representation. Refer to the original document for detailed diagrams.)
Wiring and Connections
Input/Output Circuit and Connections:
- NPN open collector output
- PNP open collector output
- Operation indicator (LEDs for POWER, Stable light ON, Unstable, Red for TEST/M/S)
- Connecting Cable (sold separately, M12 connector)
- Wiring Connection details provided for Emitter and Receiver pins.
- Connections for TEST input: When TEST input (black) of emitter is 0V, emitting stops.
- MASTER/SLAVE connections: Connect 'TEST (M/S)' of SLAVE emitter to 'SYNC' of MASTER.
Installation and Usage
- Function: Self-diagnosis, Interference protection.
- Installation: Emitter and receiver should be installed in the same up/down direction. Avoid installation where light reflected from wall surfaces can cause issues. Check normal operation with a sensing target before use (Interval distance: min. 0.5m).
- Interference Prevention: For parallel installation of multiple sensors, use the master/slave function to avoid sensing errors due to light interference. Transmission direction should be opposite between 2 sets. Baffles and installation out of interference distance are recommended.
- Proper Usage Guidelines: Follow instructions, use insulated and limited voltage/current power supply (Class 2, SELV), wait 1 sec after power supply, ground F.G. terminal for switching mode power supply, remove surge for inductive loads, keep wires short and away from high voltage lines.
- Environmental Conditions: Suitable for indoor use (within rated environment conditions), altitude max. 2,000m, pollution degree 2, installation category II.
Troubleshooting
| Cause | Troubleshooting |
|---|---|
| Not operating |
|
| Not operating sometimes |
|
| Control output is OFF even though there is no target object. |
|
| LED displays for break of light emitting element | Break of light emitting element. |
| LED displays for failure of emitter | Break of light emitting circuit. |
| LED displays for failure of receiver | Break of light receiving element. |
| LED displays for synchronous line | Synchronous line incorrect connection or disconnection. Check the wiring. Break of synchronous circuit of emitter or receiver. |
| LED displays for control output over current |
|
| LED displays for emitter malfunction | Emitter malfunction. Treat after checking the emitter display LED. |
Operation Indicator
| Display Classification | Light ON | Light OFF | Flashing by 0.5 sec or Flashing simultaneously by 0.5 sec | Cross-flashing by 0.5 sec | Sequence-flashing twice by 0.5 sec | Cross-flashing twice by 0.5 sec |
|---|---|---|---|---|---|---|
| Emitter | ||||||
| Receiver | ||||||
| Indicator | Green | Red | Yellow | |||
| Control output | ON | OFF | ||||
| Power ON | - | - | - | - | - | - |
| MASTER operation | - | - | - | - | - | - |
| SLAVE operation | - | - | - | - | - | - |
| Test input | - | - | - | - | - | - |
| Break of emitter | - | - | - | - | - | - |
| Break of light emitting element | OFF | Install mode | Normal installation | OFF | Hysteresis installation | OFF |
| Break of receiver | OFF | Abnormal installation | OFF | |||
| Control output overcurrent | Stable light ON | Unstable light ON | Unstable dark ON | Stable dark ON | ||
| Synchronous line noise | - | - | - | - | - | - |
| Emitter failure (time out) | - | - | - | - | - | - |
| Malfunction | - | - | - | - | - | - |
2411220420_Autonics-BW20-16P_C17405641.pdf