Product Overview
The AGP10 series is a piezoresistive vacuum gauge designed for medium and low vacuum measurements. It utilizes a high-precision, high-stability diffused silicon oil-filled sensor core with an integrated electronic controller and sensor module. Leveraging the piezoresistive effect of semiconductor materials and their elastic deformation properties, combined with advanced packaging and assembly techniques, the AGP10 series ensures quality and performance. Key advantages include high accuracy, excellent long-term stability, strong corrosion and wear resistance, rapid response without hysteresis, independence from gas type, and a 1-5V analog voltage output. This series is suitable for applications such as vacuum baking, vacuum packaging, vacuum welding, vacuum coating, metal smelting, and photovoltaic equipment.
Product Attributes
- Brand: ASAIR (Guangzhou Ausong Electronics Co., Ltd.)
- Material (exposed to vacuum): Stainless steel, 316 Stainless steel
- Connection Type: KF16 flange
- Interface Connector: Hirschmann connector
- Surface Treatment (Flange): Electropolishing
Technical Specifications
| Specification | Details |
|---|---|
| Model | AGP10 Series |
| Measuring Range | 0~100 Torr ... 1000 Torr |
| Accuracy | 0.5% FS |
| Power Supply | 15~24VDC |
| Output Signal | 1~5VDC |
| Response Time | 50ms |
| Load Resistance | 10k |
| Operating Temperature | 5~45C |
| Storage Temperature | -5~60C |
| Weight | 0.45Kg |
| Output Voltage Formula (1000 Torr range) | P = (V - 1) * 250 (Torr) |
| Output Voltage Formula (100 Torr range) | P = (V - 1) * 25 (Torr) |
Important Usage Notes
5.1 Compliant Use
- Use in relatively clean environments.
- Ensure all vacuum seals and surfaces are clean, undamaged, and free of particles.
- Users should possess professional knowledge for correct product usage.
- Mandatory use of KF16 flange connectors.
- Supports any installation orientation, but inverted installation is not recommended to prevent dust/dirt from entering the sensor.
- Consult the company for zero-point calibration function details.
5.2 Non-Compliant Use
- Do not use for measurements other than those specified in this manual.
- Avoid use in dirty and corrosive environments.
- Do not use in the presence of flammable gases or in explosive environments.
- Do not install replaced parts or modify the instrument without authorization.
- Do not exceed the maximum allowable pressure during operation.
Warnings and Personal Injury
Do not apply this product to safety protection devices, emergency stop equipment, or any other application where product failure could lead to personal injury, unless specifically authorized. Refer to the product datasheet and manual before installation, handling, use, or maintenance. Non-compliance may result in death or serious personal injury. The company disclaims all liability for such injuries and deaths, including costs, claims, and legal fees.
Quality Assurance
Guangzhou Ausong Electronics Co., Ltd. provides a 12-month warranty for the AGP10 series piezoresistive vacuum gauge from the date of shipment, based on the technical specifications in the product manual. If a product is found to be defective within the warranty period, the company will provide free repair or replacement. The company is responsible only for defects arising from applications meeting the product's technical conditions and does not guarantee performance in non-recommended or special scenarios, nor does it promise reliability when used with non-company matching products or circuits. Manuals are subject to change without notice. Guangzhou Ausong Electronics Co., Ltd. reserves the final interpretation rights.