Product Overview

The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for precise detection. High-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. This sensor includes advanced functions like self-diagnosis, mutual interference prevention, and external diagnosis, all housed within a robust IP65 protected structure.

Product Attributes

  • Brand: Autonics (implied by page numbering and context)
  • Product Series: BW Series
  • Protection Structure: IP65 (IEC standard)
  • Material: Case: Aluminum, Front cover, sensing part: Acrylic
  • Approvals: Not explicitly stated beyond IP65

Technical Specifications

Model BW20- (P) BW40- (P) Unit
Sensing method Through-beam type
Sensing distance 0.1 to 7 m
Min. sensing target Opaque material of min. 30mm Opaque material of min. 50mm
Optical axis pitch 20 40 mm
Number of optical axis 8 to 48 4 to 24
Sensing height 140 to 940 120 to 920 mm
Response time Max. 10 ms
Power supply 12-24VDC 10% (ripple P-P: max. 10%)
Current consumption Emitter: max. 120mA, Receiver: max. 120mA
Operation mode Light ON fixed
Control output NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC
Protection circuit Reverse polarity protection circuit, output short over current protection circuit
Light source Infrared LED (850nm modulated)
Insulation resistance Over 20M (at 500VDC megger)
Synchronization type Timing method by synchronous line
Self-diagnosis Emitter/Receiver monitoring, direct light monitoring, over current monitoring
Interference protection Interference protection by master/slave function
Noise immunity 240V the square wave noise (pulse width 1) by the noise simulator
Dielectric strength 1,000VAC 50/60Hz for 1 min
Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s (approx. 50G) in each X, Y, Z direction for 3 times
Ambient illumination Ambient light: max. 100,000lx (receiver illumination)
Ambient temperature -10 to 55, storage: -20 to 60
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Cable 5mm, 4-wire, 300mm, M12 connector
Accessory Bracket A: 4, Bracket B: 4, Bolt : 8
Weight (BW20-48 / BW40-24) Approx. 2.1kg (approx. 1.4kg for unit only) kg

Ordering Information

Item Value Description
Optical axis pitch 20 20mm
Optical axis pitch 40 40mm
Number of optical axis 04 to 48 (Range varies by model)
Control output No mark NPN open collector output
Control output P PNP open collector output
Model Prefix BW Cross-beam area sensor
Example Model BW2008P (BW + Optical axis pitch + Number of optical axis + Control output type)

Features

  • Long sensing distance up to 7m.
  • 22 types of products available with varying optical axis pitches (20/40mm) and sensing heights (120 to 940mm).
  • Minimizes unsensing area with a 20mm optical axis pitch (BW20- models).
  • High brightness LED on Emitter and Receiver for easy recognition from side, front, and long-distance.
  • Includes self-diagnosis, mutual interference prevention, and external diagnosis functions.
  • Protection structure: IP65 (IEC standard).

Dimensions

Refer to diagrams for Emitter and Receiver dimensions, including optical axis, operation indicator, and mounting points. Specific dimensions (L, A, B) are provided for various models.

Wiring and Connections

Details provided for NPN and PNP open collector outputs, including load voltage, load current, and residual voltage. Wiring diagrams illustrate connections for Emitter and Receiver, including power supply, SYNC, 0V, and TEST/OUT. Operation indicators (LEDs) and their corresponding states are described.

Functions

  • Self-diagnosis: Monitors emitter/receiver, direct light, and over current. Control output turns OFF and indicator displays error status upon detection.
  • Interference protection: Master/Slave function prevents sensing errors when multiple sensors are used in parallel.
  • External diagnosis: Stopping emitter output via TEST input (0V) allows external systems to check sensor operation.

Installation and Usage

  • Installation: Recommended to install with emitter and receiver in the same up/down direction. Avoid installation where light may reflect from walls or flat surfaces. Ensure a minimum interval distance of 0.5m between sensors.
  • Interference Prevention: For installations with more than 2 sets, use opposite transmission directions, baffles, or ensure sufficient installation distance.
  • Proper Usage: Follow instructions, use insulated and limited voltage/current power supplies (Class 2, SELV). Allow 1 second after power supply before use. For switching mode power supplies, ground F.G. and connect a condenser. Use diodes or varistors for inductive loads. Keep wiring short and away from high voltage lines. Suitable for indoor use (within rated conditions), altitude max. 2,000m, pollution degree 2, installation category II.

Troubleshooting

Cause Troubleshooting
Not operating Supply rated power. Check cable connections. Use within rated sensing distance.
Not operating sometimes Clean sensor cover. Check connector connections.
Control output is OFF even though there is no target object Ensure use within rated sensing distance. Remove obstacles blocking the light path. Move away from strong electric wave or noise generators.
LED displays for break of light emitting element Break of light emitting element.
LED displays for failure of emitter Break of light emitting circuit.
LED displays for failure of receiver Break of light receiving element.
LED displays for synchronous line Synchronous line incorrect connection or disconnection. Break of synchronous circuit.
LED displays for control output over current Control output line is shorted. Overload. Check rated load capacity.
LED displays for emitter malfunction Emitter malfunction. Check emitter display LED.