Product Overview
The UM0034-000 Liquid Auto-Fill Control Unit is an ultrasonic sensor-based system designed for non-contact liquid level monitoring and control in automated filling processes. By measuring the time of flight of ultrasonic waves, it accurately calculates container depth and liquid levels, enabling precise control of liquid addition and preventing overfills. Its non-contact operation ensures no contamination of the liquid. Ideal for water machines, water purifiers, coffee machines, and other liquid filling applications.
Product Attributes
- Brand: Audiowell International LLC
- Model Number: FA01L03-UM0034-000Z
- Part Number: UM0034-000
- Revision: A1
- Operation Theory: Ultrasonic Technology
- Functional Theory: Ultrasonic Technology
- Appearance: (Refer to dimension drawings)
Technical Specifications
| Specification | Details | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions (Unit: mm) |
| ||||||||||||||||||||||
| Installation Dimensions (Unit: mm) | Overall dimensions: 48 (L) x 60 (W) x 15.9 (H) (Refer to drawing) | ||||||||||||||||||||||
| Product Installation Requirement |
| ||||||||||||||||||||||
| Detect Range | Max. 25cm (at 15C) | ||||||||||||||||||||||
| Blind Zone | 2cm | ||||||||||||||||||||||
| Min Cup Height | >6cm (Cup wall thickness >2mm) | ||||||||||||||||||||||
| Respond Time (when put in cup) | 3s | ||||||||||||||||||||||
| Respond Time (after put in cup) | <2s | ||||||||||||||||||||||
| Power Delay | <3s | ||||||||||||||||||||||
| Output Method | Level Signal | ||||||||||||||||||||||
| Operation Environment | Indoor/Outdoor | ||||||||||||||||||||||
| Operation Temperature | 0C ~ 85C | ||||||||||||||||||||||
| Storage Temperature | -40C ~ 85C | ||||||||||||||||||||||
| Humidity | 95% (No Frozen) | ||||||||||||||||||||||
| Power Supply | DC 5V | ||||||||||||||||||||||
| Current Consumption | 12mA (Not including drive current in Output pin) | ||||||||||||||||||||||
| Connector Part No. | XH2.54 TJC4, White Color | ||||||||||||||||||||||
| Output Definition |
| ||||||||||||||||||||||
| Output Status (Output2/Output1) |
(VDD = 5V, Temp.: 15C) | ||||||||||||||||||||||
| Respond Curve | Detects 1.0cm pipe within the indicated curve area. (Refer to drawing) |
Notes:
- Distance between waste water container and sensor should be less than 25cm, ideal distance should be 18cm ~ 22cm.
- Diameter of cup should be less than 10cm.
- Interval should be more than 1s when filling 2 or more cups.
- Please check if Sensor is being correctly installed before powering up.
- There might be a failure when putting in a cup with more than half cup of water.
- Flow Rate of water should be less than 18ml/h; the higher the flow rate, the lower the accuracy.
TENTATIVE RELEASE: This specification is based on design objectives and is strictly preliminary and subject to change. Test data may exist, but this specification is subject to change based on the results of additional testing and evaluation. Application-specific specifications will be produced for approval prior to production product being released.
2411261456_Audiowell-UM0034-000_C7089899.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible