Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Long distance through beam photoelectric sensor Autonics BW40-08P with ip65 protection and aluminum case factory
<
quality Long distance through beam photoelectric sensor Autonics BW40-08P with ip65 protection and aluminum case factory
>
Specifications
Mfr. Part #:
BW40-08P
Key Attributes
Model Number: BW40-08P
Product Description

Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch (BW20-) minimizes unsensing areas, while high-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. This sensor includes essential functions such as self-diagnosis, mutual interference prevention, and external diagnosis, and boasts an IP65 protection structure for robust environmental resistance.

Product Attributes

  • Brand: Autonics
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Approvals:

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Operation Mode Control Output Protection Circuit Insulation Resistance Synchronization Type Self-Diagnosis Interference Protection Noise Immunity Dielectric Strength Vibration Shock Ambient Illumination Ambient Temperature Ambient Humidity Cable Accessory Weight (Unit Only)
BW20- (P) Through-beam type 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output (Load voltage: max. 30VDC, Load current: max. 100mA, Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC) Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Bracket A: 4, Bracket B: 4, Bolt : 8 Approx. 1.4kg
BW40- (P) Through-beam type 0.1 to 7m Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output (Load voltage: max. 30VDC, Load current: max. 100mA, Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC) Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Bracket A: 4, Bracket B: 4, Bolt : 8 Approx. 1.4kg
BW20-48 Approx. 2.1kg (Approx. 1.4kg)
BW40-24 Approx. 2.1kg (Approx. 1.4kg)
Model Number of optical axis Sensing height Optical axis pitch
BW20-08(P) 8 140mm 20mm
BW40-04(P) 4 120mm 40mm
BW20-12(P) 12 220mm 20mm
BW40-06(P) 6 200mm 40mm
BW20-16(P) 16 300mm 20mm
BW40-08(P) 8 280mm 40mm
BW20-20(P) 20 380mm 20mm
BW40-10(P) 10 360mm 40mm
BW20-24(P) 24 460mm 20mm
BW40-12(P) 12 440mm 40mm
BW20-28(P) 28 540mm 20mm
BW40-14(P) 14 520mm 40mm
BW20-32(P) 32 620mm 20mm
BW40-16(P) 16 600mm 40mm
BW20-36(P) 36 700mm 20mm
BW40-18(P) 18 680mm 40mm
BW20-40(P) 40 780mm 20mm
BW40-20(P) 20 760mm 40mm
BW20-44(P) 44 860mm 20mm
BW40-22(P) 22 840mm 40mm
BW20-48(P) 48 940mm 20mm
BW40-24(P) 24 920mm 40mm
Item Description
Optical axis pitch 20mm, 40mm
Number of optical axis 04 to 48
Control output No mark: NPN open collector output
P: PNP open collector output
Model L (mm) A, B (mm)
BW20-08(P) 160 20
BW40-04(P) 160 40
BW20-12(P) 240 20
BW40-06(P) 240 40
BW20-16(P) 320 20
BW40-08(P) 320 40
BW20-20(P) 400 20
BW40-10(P) 400 40
BW20-24(P) 480 20
BW40-12(P) 480 40
BW20-28(P) 560 20
BW40-14(P) 560 40
BW20-32(P) 640 20
BW40-16(P) 640 40
BW20-36(P) 720 20
BW40-18(P) 720 40
BW20-40(P) 800 20
BW40-20(P) 800 40
BW20-44(P) 880 20
BW40-22(P) 880 40
BW20-48(P) 960 20
BW40-24(P) 960 40
Indicator Color Status
POWER Green Stable light ON
TEST (M/S) Yellow Unstable
(Error) Red Stable light OFF
Pin No. Cable color (Emitter) Emitter Function Cable color (Receiver) Receiver Function
1 Brown 12-24VDC Brown 12-24VDC
2 White SYNC White SYNC
3 Blue 0V Blue 0V
4 Black TEST (M/S) Black OUT
Type Model Cable length (L) Color
Emitter CID4-3T 3m Black
CID4-5T 5m Gray
CID4-7T 7m Red
CID4-10T 10m Green
CID4-15T 15m Yellow
Receiver CID4-3R 3m Black
CID4-5R 5m Gray
CID4-7R 7m Red
CID4-10R 10m Green
CID4-15R 15m Yellow
Diagnosis Item Emitter Receiver
Emitter failure (time out)
Malfunction of MASTER/SLAVE line (operation in MASTER)
Damage in light receiver
Control output over current
Malfunction, disconnection, or circuit break of synchronous line
Damage in light emitter
Emitter failure (time out)
Troubleshooting Cause Troubleshooting
Not operating Power supply: Supply the rated power.
Incorrect cable connection or disconnection: Check the wiring.
Rated connection failure: Use it within rated sensing distance.
Not operating sometimes Pollution by dirt of sensor cover: Remove dirt by soft brush or cloth.
Connector connection failure: Check the assembled part of the connector.
Control output is OFF even though there is no target object. Out of rated sensing distance: Use within the rated sensing distance.
There is an obstacle to cut off the light emitted between emitter and receiver: Remove the obstacle.
There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc.: Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element
LED displays for failure of emitter Break of light emitting circuit
LED displays for failure of receiver Break of light emitting receiving element
LED displays for synchronous line Synchronous line incorrect connection or disconnection: Check the wiring.
Break of synchronous circuit of emitter or receiver: Contact Autonics Corp.
LED displays for control output over current Control output line is shorten: Check the wiring.
Over load: Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction: Treat after checking the emitter display LED.
Sensing distance (L) Installation allowable distance (D)
0.1 to 3m Min. 0.4m
3m Ltan8=min. L0.14

There can be a little different based on installation environment.

Avoid using the unit in the place where the sensor is exposed directly to the fluorescent light with high speed start or high frequency.


2411220420_Autonics-BW40-08P_C17241197.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max