Product Overview
The BWC Series Cross-Beam Area Sensor offers a minimized blind zone through a 3-point cross-beam netting method, enabling long sensing distances from 1 to 7 meters. It provides a wide range of model choices with varying optical axis counts (4 to 20), optical axis pitches (40mm, 80mm), and sensing widths (120mm to 1,040mm). Features include easy installation with an installation mode, built-in interference protection, and a self-diagnosis function that monitors sensing front screen contamination and optical axis coverage, providing external status indication. Conspicuous high luminance indicators on the emitter/receiver facilitate easy status checks from various angles and distances. This sensor is suitable for applications such as obstacle detection for subway platform screen doors (PSD) and meets Korean Railway Standard (KRS) conditions for specific models (BWC80-14HD). It boasts an IP67 protection structure.
Product Attributes
- Brand: BWC Series
- Protection Structure: IP67 (IEC standard)
- Material: Case: Aluminum, Sensing part and indicator: Acrylic
- Cable: 5mm, 4-wire, 300mm, M12 connector
- Approvals: Korean Railway Standards - KRS SG 0068
Technical Specifications
| Model | BWC40-H | BWC40-HD | BWC80-14H | BWC80-14HD |
|---|---|---|---|---|
| Sensing type | Through-beam type | |||
| Sensing distance | 1.0 to 7.0m | |||
| Sensing target | Opaque material of min. 50mm | Opaque material of min. 90mm | Opaque material of min. 50mm | Opaque material of min. 90mm |
| Optical axis pitch | 40mm | 80mm | ||
| Number of optical axes | 4/10/12/16/18/20 | 14 | 4/10/12/16/18/20 | 14 |
| Sensing height | 120 to 760mm | 1,040mm | 120 to 760mm | 1,040mm |
| Beam pattern | 3-point cross-beam netting type | |||
| Response time | Max. 50ms | |||
| Power supply | 12-24VDC 10% (ripple P-P: max. 10%) | |||
| Current consumption | Max. 100mA | |||
| Light source | Infrared LED (850nm modulated) | |||
| Operation mode | Light ON / Dark ON | Light ON / Dark ON | Light ON / Dark ON | Light ON / Dark ON |
| Control output | NPN open collector output Load voltage: max. 30VDC Load current: max. 100mA (self-diagnosis output: max 50mA) Residual voltage: max. 1VDC | |||
| Protection circuit | Reverse power polarity, output short over current protection circuit | |||
| Insulation resistance | Over 20M (at 500VDC megger) | |||
| Synchronization type | Timing method by synchronous cable | |||
| Self-diagnosis | Transmitted-received light monitoring, direct light monitoring, output circuit monitoring, self-diagnosis output (checking whether there is contamination on the front screen, or any obstacle on optical axis) | |||
| Interference protection | Interference protection by frequency changing setting | |||
| Noise immunity | 240V the square wave noise (pulse width: 1) by the noise simulation | |||
| Dielectric strength | 1,000VAC 50/60Hz for 1 min | |||
| Vibration | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | |||
| Shock | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | |||
| Environment Ambient illumination | Ambient light: max. 100,000lx (received light side illumination) | |||
| Environment Ambient temperature | -10 to 55, storage: -20 to 60 | |||
| Environment Ambient humidity | 35 to 85%RH, storage: 35 to 85%RH | |||
| Weight (approx.) | 2.1kg (approx. 1.7kg) (based on BWC80-14H, includes packaging) | |||
| Model Number Breakdown | Item | Value |
|---|---|---|
| BWC | Cross-beam area sensor | - |
| 40 (Sensing Width) | 40mm pitch | |
| 80 (Sensing Width) | 80mm pitch | |
| Number of optical axes | 4 | 120mm |
| 10 | 360mm | |
| 12 | 440mm | |
| 16 | 600mm | |
| 18 | 680mm | |
| 20 | 760mm | |
| BWC80-14 | 14 | 1,040mm |
| H / HD | Operation Mode | H: Light ON, HD: Dark ON |
| Dimensions (Emitter/Receiver) | L | A, B |
|---|---|---|
| BWC40-04H/HD | 160 | 40 |
| BWC40-10H/HD | 400 | 40 |
| BWC40-12H/HD | 480 | 40 |
| BWC40-16H/HD | 640 | 40 |
| BWC40-18H/HD | 720 | 40 |
| BWC40-20H/HD | 800 | 40 |
| BWC80-14H/HD | 1120 | 80 |
| Connection Cable Type | Model | L (m) |
|---|---|---|
| Emitter | CID4-3T | 3 |
| CID4-5T | 5 | |
| CID4-7T | 7 | |
| CID4-10T | 10 | |
| CID4-15T | 15 | |
| Receiver | CID4-3R | 3 |
| CID4-5R | 5 | |
| CID4-7R | 7 | |
| CID4-10R | 10 | |
| CID4-15R | 15 |
| Operation Mode | Receiver | Operation Indicator (green LED) | Transistor Output | Self-Diagnosis Output |
|---|---|---|---|---|
| Light ON | Received light | ON | ON | OFF |
| Light ON | Interrupted light | OFF | OFF | OFF |
| Dark ON | Received light | ON | ON | OFF |
| Dark ON | Interrupted light | OFF | OFF | OFF |
| Front screen contamination level 1 | - | Red, flashing at 1 sec interval | OFF | OFF |
| Front screen contamination level 2, covering optical axis | - | Red, flashing at 0.25 sec interval | ON | ON |
| Diagnosis Item | Description |
|---|---|
| Break of light emitting element | |
| Break of emitter | |
| Break of adjacent emitting element more than 2 | |
| Break of receiver | |
| Emitter failure | |
| Receiver failure | |
| Malfunction of synchronous cable |
| Item | Emitter Indicator | Receiver Indicator | Control Output | Self-Diagnosis Output |
|---|---|---|---|---|
| Power supply | Green | Green | - | - |
| Break of emitter | Red | - | OFF | OFF |
| Break of light emitting element | Red, flashing at 0.5 sec interval | Red, flashing at 0.5 sec interval | OFF | OFF |
| Break of adjacent emitting element more than 2 | Red, flashing simultaneously at 0.5 sec interval | Red, flashing simultaneously at 0.5 sec interval | OFF | OFF |
| Installation mode | Green | Yellow | - | - |
| Normal installation | Green | Green | - | - |
| Hysterisis section | Green | Yellow | - | - |
| Abnormal installation | Green | Red | - | - |
| Stable light ON area | ON | ON | ON | OFF |
| Unstable light ON area | ON | ON | ON | OFF |
| Unstable light OFF area | OFF | OFF | OFF | OFF |
| Stable light OFF area | OFF | OFF | OFF | OFF |
| Front screen contamination level 1 | Red, flashing at 1 sec interval | - | OFF | OFF |
| Front screen contamination level 2, covering optical axis | Red, flashing at 0.25 sec interval | - | ON | ON |
| Break of receiver | - | Red | OFF | OFF |
| Control output over current | - | Red | OFF | OFF |
| Synchronous line malfunction | - | Red | OFF | OFF |
| Emitter failure (time out) | Red | - | OFF | OFF |
| Receiver failure (time out) | - | Red | OFF | OFF |
2411220421_Autonics-BWC40-18H_C17262368.pdf