Specifications
Mfr. Part #:
BW20-40
Key Attributes
Model Number: BW20-40
Product Description

Product Overview

The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for precise detection. High-brightness LEDs on both the emitter and receiver ensure easy recognition from various angles and distances. The sensor includes advanced features such as a self-diagnosis function, mutual interference prevention, and external diagnosis capabilities, all housed in a robust IP65 rated protection structure.

Product Attributes

  • Brand: Autonics
  • Product Type: Area Sensor
  • Sensing Method: Through-beam type
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Operation Mode: Light ON fixed
  • Control Output: NPN or PNP open collector output
  • Approvals: (Specific approvals not detailed in provided text, but indicated by 'Approval' section)

Technical Specifications

Model BW20- (P) BW40- (P)
Sensing Distance 0.1 to 7m
Min. Sensing Target Opaque material of min. 30mm Opaque material of min. 50mm
Optical Axis Pitch 20mm 40mm
Number of Optical Axis 8 to 48 4 to 24
Sensing Height 140 to 940mm 120 to 920mm
Response Time Max. 10ms
Power Supply 12-24VDC 10% (ripple P-P: max. 10%)
Current Consumption Emitter: max. 120mA, Receiver: max. 120mA
Control Output Load Voltage max. 30VDC
Control Output Load Current max. 100mA
Residual Voltage (NPN) max. 1VDC
Residual Voltage (PNP) max. 2.5VDC
Insulation Resistance Over 20M (at 500VDC megger)
Synchronization Type Timing method by synchronous line
Interference Protection Interference protection by master/slave function
Noise Immunity 240V the square wave noise (pulse width 1) by the noise simulator
Dielectric Strength 1,000VAC 50/60Hz for 1 min
Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500m/s (approx. 50G) in each X, Y, Z direction for 3 times
Ambient Illumination Ambient light: max. 100,000lx (receiver illumination)
Ambient Temperature -10 to 55, storage: -20 to 60 -10 to 55, storage: -20 to 60
Ambient Humidity 35 to 85%RH, storage: 35 to 85%RH 35 to 85%RH, storage: 35 to 85%RH
Cable 5mm, 4-wire, 300mm, M12 connector
Weight (BW20-48 / BW40-24) Approx. 2.1kg (approx. 1.4kg for unit only)

Ordering Information

Item Optical axis pitch Number of optical axis Control output Model Example
No mark 20mm 04 to 48 NPN open collector output BW20-08(P)
P 40mm 4 to 48 PNP open collector output
BW 20mm 8 to 48 NPN or PNP open collector output BW20-08(P)
BW 40mm 4 to 24 NPN or PNP open collector output BW40-04(P)

Dimensions

Emitter/Receiver Dimensions:

  • 20mm
  • 2-R1.7
  • 16mm
  • 50mm
  • 25mm
  • 2mm
  • 2-4.4
  • 10mm
  • 15mm
  • 26.6mm
  • 28.6mm
  • 22.6mm
  • M12 connector
  • 5mm cable
  • 60mm (L)

Bracket A/B: (Dimensions not explicitly provided in numerical format, but shown in diagrams)

Operation Indicators

LED Color Emitter Receiver
POWER Green Stable light ON -
Unstable Yellow - Stable light ON
TEST (M/S) Red Stable light OFF -

Wiring Connection

Pin No. Cable Color (Emitter/Receiver) Emitter Function Receiver Function
1 Brown 12-24VDC 12-24VDC
2 White SYNC SYNC
3 Blue 0V 0V
4 Black TEST (M/S) OUT

Connecting Cable (Sold Separately)

Type Model Cable Length (L)
Emitter CID4-3T 3m
Emitter CID4-5T 5m
Emitter CID4-7T 7m
Emitter CID4-10T 10m
Emitter CID4-15T 15m
Receiver CID4-3R 3m
Receiver CID4-5R 5m
Receiver CID4-7R 7m
Receiver CID4-10R 10m
Receiver CID4-15R 15m

Functions

  • Self-diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Control output turns OFF if an error occurs, with operation indicator displaying status.
  • Interference Protection: Master/slave function to prevent sensing errors caused by light interference when using multiple sensors.
  • External Diagnosis: Stopping emission by setting TEST input (black) of emitter to 0V. Red LED on emitter flashes. Allows external system to verify sensor operation.

Troubleshooting

Cause Troubleshooting
Not operating
  • Power supply: Supply the rated power.
  • Cable connection: Check wiring for incorrect connection or disconnection.
  • Sensing distance: Use within the rated sensing distance.
  • Pollution: Remove dirt from sensor cover with a soft brush or cloth.
  • Connector: Check the assembled part of the connector.
Control output is OFF even though there is no target object.
  • Sensing distance: Use within the rated sensing distance.
  • Obstacle: Remove any obstacle blocking light between emitter and receiver.
  • Noise: Move away from strong electric wave or noise generators (motors, high voltage lines).
LED displays for break of light emitting element Break of light emitting element. Contact Autonics Corp.
LED displays for failure of emitter Break of light emitting circuit. Contact Autonics Corp.
LED displays for failure of receiver Break of light receiving element. Contact Autonics Corp.
LED displays for synchronous line Synchronous line incorrect connection or disconnection. Check wiring. Break of synchronous circuit of emitter or receiver. Contact Autonics Corp.
LED displays for control output over current Control output line is shorted. Check wiring. Overload. Check rated load capacity.
LED displays for emitter malfunction Emitter malfunction. Treat after checking the emitter display LED.

Proper Usage

  1. Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
  2. Use 12-24VDC power supply that is insulated, limited voltage/current, or Class 2, SELV.
  3. Use the product 1 second after supplying power. If using separate power supplies for the sensor and load, supply power to the sensor first.
  4. When using a switching mode power supply, ground the F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  5. When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  6. Wire as short as possible and keep away from high voltage lines or power lines to prevent surge and inductive noise.
  7. This unit may be used in the following environments:
    • Indoors (within rated environmental conditions)
    • Altitude max. 2,000m
    • Pollution degree 2
    • Installation category II

2411220420_Autonics-BW20-40_C17344886.pdf