Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of models with varying optical axis pitches (20mm or 40mm) and sensing heights (120mm to 940mm), minimizing unsensing areas. Featuring high-brightness LEDs for easy recognition from various angles and distances, this sensor includes self-diagnosis, mutual interference prevention, and external diagnosis functions. Its robust IP65 protection structure makes it suitable for demanding industrial environments.

Product Attributes

  • Brand: Autonics (implied by context and page numbering)
  • Product Series: BW Series
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Approvals: (symbol present)

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Operation Mode Control Output Protection Circuit Insulation Resistance Synchronization Type Interference Protection Noise Immunity Dielectric Strength Vibration Shock Ambient Illumination Ambient Temperature Ambient Humidity Cable Accessory Weight (Unit Only)
BW20- (P) Through-beam type 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Bracket A: 4, Bracket B: 4, Bolt : 8 Approx. 1.4kg
BW40- (P) Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm Approx. 1.4kg
BW20-48(P) Approx. 2.1kg (approx. 1.4kg)
BW40-24(P) Approx. 2.1kg (approx. 1.4kg)

Ordering Information

Item Optical axis pitch Number of optical axis Control output
No mark NPN open collector output 04 to 48
P PNP open collector output 4 to 48
20 20mm 8 to 48
40 40mm 4 to 24
BW Cross-beam area sensor
BW2008P Example Model

Features

  • Long sensing distance up to 7m
  • 22 types of products available (optical axis: 20/40mm, sensing height: 120 to 940mm)
  • Minimizes unsensing area with 20mm optical axis pitch (BW20-)
  • High brightness LED on Emitter and Receiver for easy recognition from side, front, and long-distance
  • Includes self-diagnosis function, mutual interference prevention function, external diagnosis function

Dimensions

Refer to diagrams provided in the original document for Emitter, Receiver, Bracket A, and Bracket B dimensions.

Input/Output Circuit and Connections

Refer to diagrams provided in the original document for NPN open collector output, PNP open collector output, wiring connections, operation indicators, and MASTER/SLAVE connections.

Functions

  • Self-diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Control output turns OFF and operation indicator displays status upon error.
  • Interference protection: Operates one sensor as MASTER and another as SLAVE to avoid sensing errors due to light interference when using multiple sensors.
  • External diagnosis: When TEST input (black) of emitter is 0V, emitting stops, and the red LED of the emitter flashes, indicating sensor operation status from an external system.

Proper Usage

  • Follow instructions in 'Proper Usage'.
  • Use 12-24VDC power supply that is insulated and limited voltage/current or Class 2, SELV.
  • Use the product 1 second after supplying power. Supply power to the sensor first if using separate power supplies for sensor and load.
  • When using a switching mode power supply, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  • When connecting a DC relay or other inductive load, remove surge using diodes or varistors.
  • Wire as short as possible and keep away from high voltage lines or power lines to prevent surge and inductive noise.
  • Suitable for indoor use (within rated environment conditions), altitude max. 2,000m, pollution degree 2, and installation category II.

troubleshooting

Cause Troubleshooting
Not operating
  • Power supply: Supply the rated power.
  • Cable connection: Check the wiring for incorrect connection or disconnection.
  • Sensing distance: Use within the rated sensing distance.
  • Pollution: Remove dirt from the sensor cover with a soft brush or cloth.
  • Connector connection: Check the assembled part of the connector.
Not operating sometimes
  • Sensing distance: Use within the rated sensing distance.
  • Obstacle: Remove any obstacle blocking the light between the emitter and receiver.
  • Noise: Move away from strong electric wave or noise generators (e.g., motors, high voltage lines).
Control output is OFF even though there is no target object
  • Sensing distance: Use within the rated sensing distance.
  • Obstacle: Remove any obstacle blocking the light between the emitter and receiver.
  • Noise: Move away from strong electric wave or noise generators (e.g., motors, high voltage lines).
LED displays for break of light emitting element Break of light emitting element. Contact Autonics Corp.
LED displays for failure of emitter Break of light emitting circuit. LED displays for emitter malfunction. Treat after checking the emitter display LED.
LED displays for failure of receiver Break of light receiving element. LED displays for receiver failure.
LED displays for synchronous line Synchronous line incorrect connection or disconnection. Check the wiring. Break of synchronous circuit of emitter or receiver. Contact Autonics Corp.
LED displays for control output over current Control output line is shorted. Check the wiring. Overload. Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction. Treat after checking the emitter display LED.