Online Service

Online Service

Contact Person
+86 136 6733 2386
quality long distance detection sensor Autonics BW20-12 with acrylic sensing part and aluminum case design factory
<
quality long distance detection sensor Autonics BW20-12 with acrylic sensing part and aluminum case design factory
>
Specifications
Mfr. Part #:
BW20-12
Key Attributes
Model Number: BW20-12
Product Description

Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch (BW20-) minimizes unsensing areas, while high-brightness LEDs on both the emitter and receiver ensure easy recognition from side, front, and long distances. This sensor includes essential functions such as self-diagnosis, mutual interference prevention, and external diagnosis. Its robust construction is rated IP65 for protection against dust and water ingress.

Product Attributes

  • Brand: Autonics
  • Product Line: BW Series
  • Type: Area Sensor, Through-beam type
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Approvals:

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Operation Mode Control Output Protection Circuit Insulation Resistance Synchronization Type Self-Diagnosis Interference Protection Noise Immunity Dielectric Strength Vibration Shock Ambient Illumination Ambient Temperature Ambient Humidity Weight (Unit Only)
BW20- (P) Through-beam type 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH Approx. 1.4kg
BW40- (P) Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm
Cable: 5mm, 4-wire, 300mm, M12 connector Accessory: Bracket A: 4, Bracket B: 4, Bolt : 8 Weight (with packaging): BW20-48: Approx. 2.1kg, BW40-24: Approx. 2.1kg

Ordering Information

Item Optical axis pitch Number of optical axis Control output
No mark NPN open collector output 04 to 48 20mm
P PNP open collector output 4 to 48 40mm

Model Example: BW2008P (BW Cross-beam area sensor, 20mm optical axis pitch, 8 optical axes, PNP output)

Features

  • Long sensing distance up to 7m.
  • 22 types of products available (optical axis: 20/40mm, sensing height: 120 to 940mm).
  • Minimizes unsensing area with 20mm optical axis pitch (BW20-).
  • High brightness LED on Emitter and Receiver for easy recognition from side, front, and long-distance.
  • Includes self-diagnosis, mutual interference prevention, and external diagnosis functions.
  • Protection structure IP65 (IEC standard).

Dimensions

(Diagrams for Emitter, Receiver, Bracket A, Bracket B are present in the source but cannot be rendered in text format. Dimensions are provided in the table below.)

Model L (mm) A, B (mm) Model L (mm) A, B (mm)
BW20-08(P) 160 20 BW40-04(P) 160 40
BW20-12(P) 240 BW40-06(P) 240
BW20-16(P) 320 BW40-08(P) 320
BW20-20(P) 400 BW40-10(P) 400
BW20-24(P) 480 BW40-12(P) 480
BW20-28(P) 560 BW40-14(P) 560
BW20-32(P) 640 BW40-16(P) 640
BW20-36(P) 720 BW40-18(P) 720
BW20-40(P) 800 BW40-20(P) 800
BW20-44(P) 880 BW40-22(P) 880
BW20-48(P) 960 BW40-24(P) 960

Input/Output Circuit and Connections

Operation Mode: Light ON fixed

Wiring Connection:

Pin No. Cable Color (Emitter) Emitter Function Cable Color (Receiver) Receiver Function
1 Brown 12-24VDC Brown 12-24VDC
2 White SYNC White SYNC
3 Blue 0V Blue 0V
4 Black TEST (M/S) Black OUT

Operation Indicator

Indicator LED Color Emitter Receiver
POWER Green Stable light ON -
Unstable Yellow - Stable light ON
TEST (M/S) Red Stable light OFF -

Troubleshooting

Troubleshooting Cause Solution
Not operating Power supply Supply the rated power.
Incorrect cable connection or disconnection Check the wiring.
Rated connection failure Use it within rated sensing distance.
Not operating sometimes Pollution by dirt of sensor cover Remove dirt by soft brush or cloth.
Connector connection failure Check the assembled part of the connector.
Control output is OFF even though there is no target object. Out of rated sensing distance Use within the rated sensing distance.
There is an obstacle to cut off the light emitted between emitter and receiver Remove the obstacle.
There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc. Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element Contact Autonics Corp.
LED displays for failure of emitter Break of light emitting circuit LED displays for failure of emitter
LED displays for failure of receiver Break of light emitting receiving element LED displays for failure of receiver
LED displays for synchronous line Synchronous line incorrect connection or disconnection Check the wiring.
Break of synchronous circuit of emitter or receiver Contact Autonics Corp.
LED displays for control output over current Control output line is shorten Check the wiring.
Over load Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction Treat after checking the emitter display LED.

Proper Usage

  • Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
  • 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
  • When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  • When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  • Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
  • This unit may be used in the following environments: Indoors (in the environment condition rated in 'Specifications') Altitude max. 2,000m Pollution degree 2 Installation category II

2411220420_Autonics-BW20-12_C17474862.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max