Product Overview
The D-44 BW Series Area Sensor is a high-performance through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for detecting smaller objects. High-brightness LEDs on both the emitter and receiver ensure easy recognition from side, front, and long distances. The sensor incorporates essential functions like self-diagnosis, mutual interference prevention, and external diagnosis, along with an IP65 protection structure for robust operation in industrial environments.
Product Attributes
- Brand: Autonics (implied by context and page numbering)
- Product Series: BW Series
- Protection Structure: IP65 (IEC standard)
- Case Material: Aluminum
- Front Cover/Sensing Part Material: Acrylic
- Certifications: Approval (specific certifications not detailed)
Technical Specifications
| Model | BW20- (P) | BW40- (P) | Unit |
|---|---|---|---|
| Sensing Method | Through-beam type | ||
| Sensing Distance | 0.1 to 7 | m | |
| Min. Sensing Target | Opaque material of min. 30mm | Opaque material of min. 50mm | |
| Optical Axis Pitch | 20 | 40 | mm |
| Number of Optical Axis | 8 to 48 | 4 to 24 | |
| Sensing Height | 140 to 940 | 120 to 920 | mm |
| Response Time | Max. 10 | ms | |
| Power Supply | 12-24VDC 10% (ripple P-P: max. 10%) | ||
| Current Consumption | Emitter: max. 120mA, Receiver: max. 120mA | ||
| Operation Mode | Light ON fixed | ||
| Control Output | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | ||
| Protection Circuit | Reverse polarity protection circuit, output short over current protection circuit | ||
| Light Source | Infrared LED (850nm modulated) | ||
| Insulation Resistance | Over 20M (at 500VDC megger) | ||
| Synchronization Type | Timing method by synchronous line | ||
| Self-Diagnosis | Emitter/Receiver monitoring, direct light monitoring, over current monitoring | ||
| Interference Protection | Interference protection by master/slave function | ||
| Noise Immunity | 240V the square wave noise (pulse width 1) by the noise simulator | ||
| Dielectric Strength | 1,000VAC 50/60Hz for 1 min | ||
| Vibration | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | ||
| Shock | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | ||
| Ambient Illumination | Ambient light: max. 100,000lx (receiver illumination) | ||
| Ambient Temperature | -10 to 55, storage: -20 to 60 | ||
| Ambient Humidity | 35 to 85%RH, storage: 35 to 85%RH | ||
| Cable | 5mm, 4-wire, 300mm, M12 connector | ||
| Accessory | Bracket A: 4, Bracket B: 4, Bolt : 8 | ||
| Weight (Packaging included) | Approx. 2.1 | Approx. 2.1 | kg |
| Weight (Unit only) | Approx. 1.4 | Approx. 1.4 | kg |
Ordering Information
| Item | Options | Example Model |
|---|---|---|
| Optical Axis Pitch | 20mm, 40mm | BW20, BW40 |
| Number of Optical Axis | 04 to 48 | 08, 24, 48 |
| Control Output | No mark: NPN open collector output; P: PNP open collector output | BW20-08 |
| Base Model | BW: Cross-beam area sensor | BW |
Example: BW20-08P
Features
- Long sensing distance up to 7m.
- 22 types of products available (optical axis: 20/40mm, sensing height: 120 to 940mm).
- Minimizes unsensing area with 20mm optical axis pitch (BW20- models).
- High brightness LED emitter and receiver for easy recognition from side, front, and long-distance.
- Includes self-diagnosis, mutual interference prevention, and external diagnosis functions.
- Protection structure IP65 (IEC standard).
Dimensions
(Diagrams and specific model dimensions are present in the source but cannot be rendered as text. Refer to the original document for visual representations.)
- Bracket A Mounting: Provided dimensions for various models (e.g., BW20-08(P) L=160mm, BW40-04(P) L=160mm).
- Bracket B Mounting: Provided dimensions for various models.
- Emitter/Receiver Dimensions: 20mm, 26.6mm height for BW20 series; 20mm, 28.6mm height for BW40 series. Overall dimensions including mounting points are detailed.
Wiring and Connections
- NPN Open Collector Output: Details on main circuit and connections.
- PNP Open Collector Output: Details on main circuit and connections.
- Input/Output Circuit: Diagrams for NPN and PNP outputs.
- Operation Indicator: LED colors (Green, Yellow, Red) and their meanings (POWER, Stable light ON, Unstable, TEST (M/S), Stable light OFF).
- Connecting Cable: Sold separately (CID4-3T/5T/7T/10T/15T for Emitter, CID4-3R/5R/7R/10R/15R for Receiver).
- TEST Input: Connections for external diagnosis.
- MASTER/SLAVE Connections: For interference prevention.
Functions
- Self-Diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Operation indicator displays diagnosis status.
- Interference Protection: Master/Slave function to prevent mutual interference when using multiple sensors.
- External Diagnosis: Initiated by grounding the TEST input of the emitter to 0V, stopping emission and indicating status via the red LED.
Troubleshooting
| Cause | Troubleshooting |
|---|---|
| Not operating | Supply rated power. Check cable connections. Use within rated sensing distance. |
| Not operating sometimes | Clean sensor cover. Check connector connections. |
| Control output is OFF even though there is no target object | Ensure within rated sensing distance. Remove any obstacles between emitter and receiver. Shield from strong electric waves or noise generators. |
| LED displays for break of light emitting element | Break of light emitting element. |
| LED displays for failure of emitter | Break of light emitting circuit. |
| LED displays for failure of receiver | Break of light receiving element. |
| LED displays for synchronous line | Synchronous line incorrect connection or disconnection. Break of synchronous circuit. |
| LED displays for control output over current | Output line is shorted. Overload. |
| LED displays for emitter malfunction | Emitter malfunction. |
Proper Usage
- Follow instructions in 'Proper Usage'.
- Use 12-24VDC power supply that is insulated and limited voltage/current or Class 2, SELV.
- Wait 1 second after supplying power before use. Supply power to sensor first if using separate power supplies.
- For switching mode power supplies, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
- When connecting inductive loads like DC relays, remove surge using diodes or varistors.
- Wire as short as possible and keep away from high voltage lines or power lines to prevent surge and inductive noise.
- Suitable for indoor use (within rated environment conditions), altitude max. 2,000m, pollution degree 2, installation category II.