Product Overview
The D-44 BW Series Area Sensor is a high-performance through-beam photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, while high-brightness LEDs ensure easy recognition from various angles and distances. This sensor includes essential functions such as self-diagnosis, mutual interference prevention, and external diagnosis, all housed within an IP65 protected structure. It is ideal for industrial applications requiring reliable and precise detection.
Product Attributes
- Brand: Autonics
- Product Series: BW Series
- Protection Structure: IP65 (IEC standard)
- Material: Case: aluminum, Front cover, sensing part: acrylic
- Cable: 5mm, 4-wire, 300mm, M12 connector
- Approvals:
Technical Specifications
| Model | Sensing Method | Sensing Distance | Min. Sensing Target | Optical Axis Pitch | Number of Optical Axis | Sensing Height | Response Time | Power Supply | Current Consumption | Operation Mode | Control Output | Light Source | Insulation Resistance | Synchronization Type | Interference Protection | Noise Immunity | Dielectric Strength | Vibration | Shock | Ambient Illumination | Ambient Temperature | Ambient Humidity | Weight (Unit Only) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BW20- (P) | Through-beam type | 0.1 to 7m | Opaque material of min. 30mm | 20mm | 8 to 48 | 140 to 940mm | Max. 10ms | 12-24VDC 10% (ripple P-P: max. 10%) | Emitter: max. 120mA, Receiver: max. 120mA | Light ON fixed | NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC | Infrared LED (850nm modulated) | Over 20M (at 500VDC megger) | Timing method by synchronous line | Interference protection by master/slave function | 240V the square wave noise (pulse width 1) by the noise simulator | 1,000VAC 50/60Hz for 1 min | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | 500m/s 2 (approx. 50G) in each X, Y, Z direction for 3 times | Ambient light: max. 100,000lx (receiver illumination) | -10 to 55, storage: -20 to 60 | 35 to 85%RH, storage: 35 to 85%RH | Approx. 1.4kg |
| BW40- (P) | Opaque material of min. 50mm | 40mm | 4 to 24 | 120 to 920mm | Approx. 1.4kg | ||||||||||||||||||
| BW20-48(P) | Approx. 2.1kg (approx. 1.4kg) | ||||||||||||||||||||||
| BW40-24(P) | Approx. 2.1kg (approx. 1.4kg) | ||||||||||||||||||||||
Ordering Information
| Item | Optical axis pitch | Number of optical axis | Control output |
|---|---|---|---|
| No mark | 20mm | 04 to 48 | NPN open collector output |
| P | 40mm | 4 to 48 | PNP open collector output |
| BW | BW Cross-beam area sensor | ||
| 20 | 20mm | ||
| 40 | 40mm | ||
| 08 | 8 | ||
| P | PNP open collector output |
Dimensions
Bracket A
Bracket B
Emitter
- Model: BW20-08(P) L: 160 A, B: 20
- Model: BW20-12(P) L: 240
- Model: BW20-16(P) L: 320
- Model: BW20-20(P) L: 400
- Model: BW20-24(P) L: 480
- Model: BW20-28(P) L: 560
- Model: BW20-32(P) L: 640
- Model: BW20-36(P) L: 720
- Model: BW20-40(P) L: 800
- Model: BW20-44(P) L: 880
- Model: BW20-48(P) L: 960
Receiver
- Model: BW40-04(P) L: 160 A, B: 40
- Model: BW40-06(P) L: 240
- Model: BW40-08(P) L: 320
- Model: BW40-10(P) L: 400
- Model: BW40-12(P) L: 480
- Model: BW40-14(P) L: 560
- Model: BW40-16(P) L: 640
- Model: BW40-18(P) L: 720
- Model: BW40-20(P) L: 800
- Model: BW40-22(P) L: 880
- Model: BW40-24(P) L: 960
Dimensions (Emitter): 20, 2-R1.7, 16, 50, 25, 2, 2-4.4, 16, 2.3, 10, 15, 18, 20, 2-R1.7, 19, 50, 32, 2, 2-4.4, 10, 2.3, 10, 15, 28.6, 22.6, 28.6, 22.6
Dimensions (Receiver): M12, 5, 60
Connections and Circuits
NPN open collector output
PNP open collector output
Input/Output Circuit and Connections
- Emitter: Pin 1: Brown (12-24VDC), Pin 2: White (SYNC), Pin 3: Blue (0V), Pin 4: Black (TEST (M/S))
- Receiver: Pin 1: Brown (12-24VDC), Pin 2: White (SYNC), Pin 3: Blue (0V), Pin 4: Black (OUT)
Connecting Cable (sold separately)
- Emitter Cable: CID4-3T (3m), CID4-5T (5m), CID4-7T (7m), CID4-10T (10m), CID4-15T (15m)
- Receiver Cable: CID4-3R (3m), CID4-5R (5m), CID4-7R (7m), CID4-10R (10m), CID4-15R (15m)
Main circuit
- Emitter: +V (Brown), SYNC (White), 0V (Blue), TEST (M/S) (Black)
- Receiver: +V (Brown), SYNC (White), 0V (Blue), OUT (Black)
Operation Indicator
- LED Color: Green (POWER), Yellow (Unstable), Red (TEST (M/S))
Functions
- Self-diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Control output turns OFF and operation indicator displays error status.
- Interference protection: Operates a sensor as MASTER and another as SLAVE to avoid sensing errors due to light interference.
- External diagnosis: When TEST input (black) of emitter is 0V, emitting stops, and the red LED of the emitter flashes. This allows external systems to verify sensor operation.
- Protection circuit: Reverse polarity protection circuit, output short over current protection circuit.
Installation and Usage
- Mounting: Bracket A, Bracket B
- Operation mode: Light ON fixed
- Installation: Emitter and receiver should be installed in the same up/down direction. Avoid installation where light reflected from walls or flat surfaces can be an issue. Ensure normal operation with a sensing target before use.
- Interference Prevention: When using multiple sensors in parallel, install them with opposite transmission directions, use baffles, or ensure installation outside the interference distance. Use the interference protection function (MASTER/SLAVE).
- Proper Usage: Follow instructions, use insulated and limited voltage/current power supply (Class 2, SELV). Wait 1 second after supplying power. Ground F.G. terminal and connect a condenser when using switching mode power supply. Remove surge with diodes or varistors for inductive loads. Keep wires short and away from high voltage lines.
Troubleshooting
| Cause | Troubleshooting |
|---|---|
| Not operating | Supply the rated power. Check wiring for incorrect connection or disconnection. Use within rated sensing distance. |
| Not operating sometimes | Remove dirt from sensor cover. Check connector connections. |
| Control output is OFF even though there is no target object | Use within rated sensing distance. Remove obstacles blocking light. Move away from strong electric wave or noise generators. |
| LED displays for break of light emitting element | Break of light emitting element. |
| LED displays for failure of emitter | Break of light emitting circuit. |
| LED displays for failure of receiver | Break of light receiving element. |
| LED displays for synchronous line | Synchronous line incorrect connection or disconnection. Break of synchronous circuit of emitter or receiver. |
| LED displays for control output over current | Control output line is shorted. Overload. |
| LED displays for emitter malfunction | Emitter malfunction. |
Operation Indicator Display Classification
| Display Classification | Emitter Indicator | Receiver Indicator | Control Output |
|---|---|---|---|
| Light ON | Green | Green | ON |
| Light OFF | Red | Red | OFF |
| Flashing by 0.5 sec | Yellow | Yellow | ON/OFF |
| Flashing simultaneously by 0.5 sec | Yellow | Yellow | ON/OFF |
| Cross-flashing by 0.5 sec | Yellow | Yellow | ON/OFF |
| Sequence-flashing twice by 0.5 sec | Yellow | Yellow | ON/OFF |
| Cross-flashing twice by 0.5 sec | Yellow | Yellow | ON/OFF |
| Power ON | - | - | - |
| MASTER operation | - | - | - |
| SLAVE operation | - | - | - |
| Test input | - | - | - |
| Break of emitter | Red | - | OFF |
| Install mode | - | - | OFF |
| Normal installation | - | - | OFF |
| Hysteresis installation | - | - | OFF |
| Abnormal installation | - | - | OFF |
| Stable light ON | - | Green | ON |
| Unstable light ON | - | Yellow | ON |
| Unstable dark ON | - | Yellow | OFF |
| Stable dark ON | - | Red | OFF |
| Break of receiver | - | Red | OFF |
| Control output overcurrent | - | Red | OFF |
| Synchronous line noise | - | Red | OFF |
| Emitter failure (time out) | Red | - | OFF |
| Malfunction | Red | Red | OFF |
Environmental Conditions
- Installation Category: II
- Pollution Degree: 2
- Altitude: max. 2,000m
- Environment Resistance: Non-freezing or condensation
2411220420_Autonics-BW40-12_C17257857.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible