Product Description

Product Overview

The D-44 BW Series Area Sensor is a through-beam type photoelectric sensor designed for long-distance detection up to 7 meters. It offers a wide range of models with varying optical axis pitches (20mm and 40mm) and sensing heights (120mm to 940mm), minimizing unsensing areas. Featuring high-brightness LEDs for clear visibility from multiple angles and distances, this sensor includes essential functions like self-diagnosis, mutual interference prevention, and external diagnosis. Its robust IP65 protection structure makes it suitable for demanding industrial environments.

Product Attributes

  • Brand: Autonics (implied by product numbering and context)
  • Product Line: BW Series Area Sensor
  • Sensing Method: Through-beam type
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Operation Mode: Light ON fixed
  • Approvals: (symbol present)

Technical Specifications

Model Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Control Output Insulation Resistance Noise Immunity Dielectric Strength Vibration Shock Ambient Temperature Ambient Humidity Cable Weight (BW20-48 / BW40-24)
BW20- (P) 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Over 20M (at 500VDC megger) 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Approx. 2.1kg (approx. 1.4kg)
BW40- (P) 0.1 to 7m Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm

Ordering Information

Item Optical axis pitch Number of optical axis Control output
No mark NPN open collector output 04 to 48 20mm
P PNP open collector output 4 to 48 40mm
(Model Prefix) BW Cross-beam area sensor

Features

  • Long sensing distance up to 7m
  • 22 types of products available (optical axis: 20/40mm, sensing height: 120 to 940mm)
  • Minimizes unsensing area with 20mm optical axis pitch (BW20-)
  • Easy to recognize at side, front, and long-distance by high brightness LED of Emitter and Receiver
  • Includes self-diagnosis function, mutual interference prevention function, external diagnosis function

Dimensions

(Diagrams for Emitter, Receiver, Bracket A, Bracket B are present in the source but cannot be represented in text format.)

Input/Output Circuit and Connections

Operation mode: Light ON fixed

Control Output: NPN or PNP open collector output

  • Load voltage: max. 30VDC
  • Load current: max. 100mA
  • Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC

Protection Circuit: Reverse polarity protection circuit, output short over current protection circuit

Synchronization type: Timing method by synchronous line

Wiring Connections:

  • Emitter/Receiver Pinout: 1 (Brown: +V), 2 (White: SYNC), 3 (Blue: 0V), 4 (Black: TEST (M/S) / OUT)
  • Main Circuit Connections for Emitter and Receiver are detailed for NPN and PNP outputs.

Operation Indicator

LED Color Emitter Receiver Status
Green POWER - Stable light ON
Yellow - Unstable Stable light ON
Red TEST (M/S) Stable light OFF Stable light OFF

Functions

  • Self-diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Control output turns OFF if an error occurs, and the operation indicator displays the status.
  • Interference protection: Operates a sensor as MASTER and another as SLAVE to avoid sensing errors caused by light interference when using multiple sensors in parallel.
  • External diagnosis: When TEST input (black) of emitter is 0V, emitting stops, and the red LED of the emitter flashes, allowing external systems to verify sensor operation.

Troubleshooting

Cause Troubleshooting
Not operating
  • Power supply: Supply the rated power.
  • Incorrect cable connection or disconnection: Check the wiring.
  • Rated connection failure: Use within the rated sensing distance.
Not operating sometimes
  • Pollution by dirt of sensor cover: Remove dirt by soft brush or cloth.
  • Connector connection failure: Check the assembled part of the connector.
Control output is OFF even though there is no target object.
  • Out of rated sensing distance: Use within the rated sensing distance.
  • There is an obstacle to cut off the light emitted between emitter and receiver: Remove the obstacle.
  • There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc.: Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element
LED displays for failure of emitter Break of light emitting circuit
LED displays for failure of receiver Break of light receiving element
LED displays for synchronous line Synchronous line incorrect connection or disconnection: Check the wiring. Break of synchronous circuit of emitter or receiver.
LED displays for control output over current
  • Control output line is shorten: Check the wiring.
  • Over load: Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction: Treat after checking the emitter display LED.

Proper Usage

  • Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
  • 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
  • When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  • When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  • Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
  • This unit may be used in the following environments:
    • Indoors (in the environment condition rated in 'Specifications')
    • Altitude max. 2,000m
    • Pollution degree 2
    • Installation category II