Online Service

Online Service

Contact Person
+86 136 6733 2386
quality High visibility area sensor Autonics BW40-24P with high brightness leds and ip65 protection structure factory
<
quality High visibility area sensor Autonics BW40-24P with high brightness leds and ip65 protection structure factory
>
Specifications
Mfr. Part #:
BW40-24P
Key Attributes
Model Number: BW40-24P
Product Description

Product Overview

The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm and 40mm, and sensing heights from 120mm to 940mm. The 20mm optical axis pitch (BW20- models) minimizes unsensing areas, ensuring comprehensive coverage. High-brightness LEDs on both the emitter and receiver enhance visibility from side, front, and long distances. Integrated self-diagnosis, mutual interference prevention, and external diagnosis functions ensure reliable operation and easy troubleshooting. The sensor boasts an IP65 protection structure according to IEC standards, making it suitable for demanding industrial environments.

Product Attributes

  • Brand: Autonics
  • Product Series: BW Series
  • Type: Area Sensor
  • Sensing Method: Through-beam type
  • Protection Structure: IP65 (IEC standard)
  • Material (Case): Aluminum
  • Material (Front cover, sensing part): Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Operation Mode: Light ON fixed
  • Control Output: NPN or PNP open collector output
  • Approvals:

Technical Specifications

Model Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption (Emitter/Receiver) Load Voltage (Max.) Load Current (Max.) Insulation Resistance Dielectric Strength Vibration Shock Ambient Temperature Ambient Humidity Cable Weight (Unit Only)
BW20- (P) 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Max. 120mA / Max. 120mA Max. 30VDC Max. 100mA Over 20M (at 500VDC megger) 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at 10-55Hz (X, Y, Z for 2 hrs) 500m/s (approx. 50G) (X, Y, Z for 3 times) -10 to 55 (storage: -20 to 60) 35 to 85%RH (storage: 35 to 85%RH) 5mm, 4-wire, 300mm, M12 connector Approx. 1.4kg
BW40- (P) 0.1 to 7m Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Max. 120mA / Max. 120mA Max. 30VDC Max. 100mA Over 20M (at 500VDC megger) 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at 10-55Hz (X, Y, Z for 2 hrs) 500m/s (approx. 50G) (X, Y, Z for 3 times) -10 to 55 (storage: -20 to 60) 35 to 85%RH (storage: 35 to 85%RH) 5mm, 4-wire, 300mm, M12 connector Approx. 1.4kg
Model Example Optical axis pitch Number of optical axis Control output
BW2008P 20mm 8 PNP
BW4024 40mm 24 NPN

Dimensions:

Model L (Sensing Height) A, B (Bracket Length)
BW20-08(P) 140mm 20mm
BW40-04(P) 120mm 40mm
BW20-12(P) 240mm 20mm
BW40-06(P) 200mm 40mm
BW20-16(P) 320mm 20mm
BW40-08(P) 280mm 40mm
BW20-20(P) 400mm 20mm
BW40-10(P) 360mm 40mm
BW20-24(P) 480mm 20mm
BW40-12(P) 440mm 40mm
BW20-28(P) 560mm 20mm
BW40-14(P) 520mm 40mm
BW20-32(P) 640mm 20mm
BW40-16(P) 600mm 40mm
BW20-36(P) 720mm 20mm
BW40-18(P) 680mm 40mm
BW20-40(P) 800mm 20mm
BW40-20(P) 760mm 40mm
BW20-44(P) 880mm 20mm
BW40-22(P) 840mm 40mm
BW20-48(P) 940mm 20mm
BW40-24(P) 920mm 40mm

Weight:

Model Weight (including packaging) Weight (unit only)
BW20-48(P) Approx. 2.1kg Approx. 1.4kg
BW40-24(P) Approx. 2.1kg Approx. 1.4kg

Accessories: Bracket A (4 pcs), Bracket B (4 pcs), Bolt (8 pcs)

Connecting Cables (Sold Separately):

Emitter Cable Model Receiver Cable Model Cable Length
CID4-3T CID4-3R 3m
CID4-5T CID4-5R 5m
CID4-7T CID4-7R 7m
CID4-10T CID4-10R 10m
CID4-15T CID4-15R 15m

Operation Indicator:

LED Color Emitter Receiver
Green POWER Stable light ON
Yellow - Unstable
Red TEST (M/S) Stable light OFF

Troubleshooting:

Cause Troubleshooting
Not operating
  • Supply the rated power.
  • Check the wiring for incorrect connection or disconnection.
  • Use within the rated sensing distance.
  • Remove dirt from the sensor cover with a soft brush or cloth.
  • Check the assembled part of the connector.
Control output is OFF even though there is no target object.
  • Use within the rated sensing distance.
  • Remove any obstacle that may cut off the light between the emitter and receiver.
  • Relocate away from strong electric wave or noise generators (e.g., motors, electric generators, high voltage lines).
LED displays for break of light emitting element Break of light emitting element. Contact Autonics Corp.
LED displays for failure of emitter Break of light emitting circuit. LED displays for emitter malfunction. Treat after checking the emitter display LED.
LED displays for failure of receiver Break of light receiving element. LED displays for receiver failure. Contact Autonics Corp.
LED displays for synchronous line Synchronous line incorrect connection or disconnection. Check the wiring. Break of synchronous circuit of emitter or receiver. Contact Autonics Corp.
LED displays for control output over current Control output line is shorted. Check the wiring. Over load. Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction. Treat after checking the emitter display LED.