Mfr. Part #:
BW20-40P
Key Attributes
Model Number: BW20-40P
Product Description

Product Overview

The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide range of configurations with 22 product types, featuring optical axis pitches of 20mm or 40mm and sensing heights from 120mm to 940mm. The 20mm optical axis pitch minimizes unsensing areas, making it ideal for precise detection. Both emitter and receiver units are equipped with high-brightness LEDs for easy recognition from various angles and distances. This sensor includes essential functions such as self-diagnosis, mutual interference prevention, and external diagnosis, ensuring reliable operation in industrial environments. Its robust IP65 protection structure (IEC standard) makes it suitable for demanding applications.

Product Attributes

  • Brand: Autonics
  • Product Series: BW Series
  • Protection Structure: IP65 (IEC standard)
  • Case Material: Aluminum
  • Front Cover/Sensing Part Material: Acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Approvals:

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Operation Mode Control Output Protection Circuit Insulation Resistance Synchronization Type Self-Diagnosis Interference Protection Noise Immunity Dielectric Strength Vibration Shock Ambient Illumination Ambient Temperature Ambient Humidity Cable Weight (Unit Only)
BW20-(P) Through-beam type 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Approx. 1.4kg
BW40-(P) Through-beam type 0.1 to 7m Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Approx. 1.4kg
BW20-48 (Overall Weight) Approx. 2.1kg (includes packaging)
BW40-24 (Overall Weight) Approx. 2.1kg (includes packaging)
Model Number Breakdown BW Optical Axis Pitch Number of Optical Axis Control Output
Description Cross-beam area sensor 20mm 08 to 48 No mark: NPN open collector output
Example BW 20 08 (P): PNP open collector output
40mm 04 to 24
Dimensions (Unit: mm) Emitter Receiver
Model L A, B L A, B
BW20-08(P) 160 20 160 20
BW40-04(P) 160 40 160 40
BW20-12(P) 240 20 240 20
BW40-06(P) 240 40 240 40
BW20-16(P) 320 20 320 20
BW40-08(P) 320 40 320 40
BW20-20(P) 400 20 400 20
BW40-10(P) 400 40 400 40
BW20-24(P) 480 20 480 20
BW40-12(P) 480 40 480 40
BW20-28(P) 560 20 560 20
BW40-14(P) 560 40 560 40
BW20-32(P) 640 20 640 20
BW40-16(P) 640 40 640 40
BW20-36(P) 720 20 720 20
BW40-18(P) 720 40 720 40
BW20-40(P) 800 20 800 20
BW40-20(P) 800 40 800 40
BW20-44(P) 880 20 880 20
BW40-22(P) 880 40 880 40
BW20-48(P) 960 20 960 20
BW40-24(P) 960 40 960 40
Model Number of optical axis Sensing height Optical axis pitch
BW20-08(P) 8 140mm 20mm
BW40-04(P) 4 120mm 40mm
BW20-12(P) 12 220mm 20mm
BW40-06(P) 6 200mm 40mm
BW20-16(P) 16 300mm 20mm
BW40-08(P) 8 280mm 40mm
BW20-20(P) 20 380mm 20mm
BW40-10(P) 10 360mm 40mm
BW20-24(P) 24 460mm 20mm
BW40-12(P) 12 440mm 40mm
BW20-28(P) 28 540mm 20mm
BW40-14(P) 14 520mm 40mm
BW20-32(P) 32 620mm 20mm
BW40-16(P) 16 600mm 40mm
BW20-36(P) 36 700mm 20mm
BW40-18(P) 18 680mm 40mm
BW20-40(P) 40 780mm 20mm
BW40-20(P) 20 760mm 40mm
BW20-44(P) 44 860mm 20mm
BW40-22(P) 22 840mm 40mm
BW20-48(P) 48 940mm 20mm
BW40-24(P) 24 920mm 40mm
Operation Indicator Emitter Receiver Control Output
Light ON Green Green ON
Light OFF Red Yellow OFF
Stable light ON - ON ON
Unstable light ON - ON ON
Unstable dark ON - OFF OFF
Stable dark ON - OFF OFF
TEST input Flashing by 0.5 sec - -
Break of emitter Flashing simultaneously by 0.5 sec - OFF
Emitter failure (time out) Cross-flashing by 0.5 sec - OFF
Break of receiver - Red OFF
Control output overcurrent - Red OFF
Synchronous line noise - Red OFF
Troubleshooting Cause Solution
Not operating Power supply Supply the rated power.
Incorrect cable connection or disconnection Check the wiring.
Rated connection failure Use it within rated sensing distance.
Not operating sometimes Pollution by dirt of sensor cover Remove dirt by soft brush or cloth.
Connector connection failure Check the assembled part of the connector.
Control output is OFF even though there is no target object. Out of rated sensing distance Use within the rated sensing distance.
There is an obstacle to cut off the light emitted between emitter and receiver Remove the obstacle.
There is a strong electric wave or noise generated by motor, electric generator, high voltage line etc. Put away the strong electric wave or noise generator.
LED displays for break of light emitting element Break of light emitting element Contact Autonics Corp.
LED displays for failure of emitter Break of light emitting circuit Contact Autonics Corp.
LED displays for failure of receiver Break of light emitting receiving element Contact Autonics Corp.
LED displays for synchronous line Synchronous line incorrect connection or disconnection Check the wiring.
Break of synchronous circuit of emitter or receiver Contact Autonics Corp.
LED displays for control output over current Control output line is shorten Check the wiring.
Over load Check the rated load capacity.
LED displays for emitter malfunction Emitter malfunction Treat after checking the emitter display LED.
Proper Usage Environment Conditions
Indoor use Environment condition rated in 'Specifications'
Altitude Max. 2,000m
Pollution degree 2
Installation category II