Product Overview
The BWC Series Cross-Beam Area Sensor offers a minimized blind zone through a 3-point cross-beam netting method, enabling a long sensing distance of 1 to 7 meters. It provides a wide range of model choices, featuring various optical axis counts (4 to 20), optical axis pitches (40, 80mm), and sensing widths (120 to 1,040mm). Key features include an easy installation mode, built-in interference protection, and a self-diagnosis function that monitors front screen contamination and optical axis obstruction, providing status feedback via external equipment. High-luminance indicators on the emitter and receiver ensure easy status checks from various angles and distances. This sensor is suitable for applications requiring obstacle detection, such as subway platform screen doors (PSD), and meets Korean Railway Standard (KRS) conditions for specific models (BWC80-14HD). The protection structure is rated IP67 (IEC standard).
Product Attributes
- Brand: BWC Series
- Protection Structure: IP67 (IEC standard)
- Material: Case: Aluminum, Sensing part and indicator: Acrylic
- Cable: 5mm, 4-wire, 300mm, M12 connector
- Accessory: Bracket A (4), Bracket B (4), Fixing bolt (8)
- Approval: Korean Railway Standards - KRS SG 0068
Technical Specifications
| Model | BWC40-H | BWC40-HD | BWC80-14H | BWC80-14HD |
|---|---|---|---|---|
| Sensing type | Through-beam type | |||
| Sensing distance | 1.0 to 7.0m | |||
| Sensing target | Opaque material of min. 50mm | Opaque material of min. 90mm | Opaque material of min. 90mm | |
| Optical axis pitch | 40mm | 80mm | ||
| Number of optical axes | 4/10/12/16/18/20 | 14 | 14 | |
| Sensing height | 120 to 760mm | 1,040mm | 1,040mm | |
| Beam pattern | 3-point cross-beam netting type | |||
| Response time | Max. 50ms | |||
| Power supply | 12-24VDC 10% (ripple P-P: max. 10%) | |||
| Current consumption | Max. 100mA | |||
| Light source | Infrared LED (850nm modulated) | |||
| Operation mode | Light ON / Dark ON | Light ON / Dark ON | Light ON / Dark ON | Light ON / Dark ON |
| Control output | NPN open collector output Load voltage: max. 30VDC Load current: max. 100mA (self-diagnosis output: max 50mA) Residual voltage: max. 1VDC | |||
| Protection circuit | Reverse power polarity, output short over current protection circuit | |||
| Insulation resistance | Over 20M (at 500VDC megger) | |||
| Synchronization type | Timing method by synchronous cable | |||
| Self-diagnosis | Transmitted-received light monitoring, direct light monitoring, output circuit monitoring, self-diagnosis output (checking whether there is contamination on the front screen, or any obstacle on optical axis) | |||
| Interference protection | Interference protection by frequency changing setting | |||
| Noise immunity | 240V the square wave noise (pulse width: 1) by the noise simulation | |||
| Dielectric strength | 1,000VAC 50/60Hz for 1 min | |||
| Vibration | 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours | |||
| Shock | 500m/s (approx. 50G) in each X, Y, Z direction for 3 times | |||
| Ambient illumination | Ambient light: max. 100,000lx (received light side illumination) | |||
| Ambient temperature | -10 to 55, storage: -20 to 60 | |||
| Ambient humidity | 35 to 85%RH, storage: 35 to 85%RH | |||
| Weight (approx.) | 2.1kg (1.7kg for unit only) (based on BWC80-14H) | |||
| Model Number Breakdown | Description |
|---|---|
| BWC | Cross-beam area sensor |
| 40 / 80 | Optical axis pitch (40mm / 80mm) |
| 4 to 20 / 14 | Number of optical axes |
| H / HD | Operation mode (H: Light ON, HD: Dark ON) |
| Model | Number of optical axis | Sensing height | Optical axis pitch |
|---|---|---|---|
| BWC40-04H/HD | 4 | 120mm | 40mm |
| BWC40-10H/HD | 10 | 360mm | 40mm |
| BWC40-12H/HD | 12 | 440mm | 40mm |
| BWC40-16H/HD | 16 | 600mm | 40mm |
| BWC40-18H/HD | 18 | 680mm | 40mm |
| BWC40-20H/HD | 20 | 760mm | 40mm |
| BWC80-14H/HD | 14 | 1,040mm | 80mm |
| Model | L (mm) | A, B (mm) |
|---|---|---|
| BWC40-04H/HD | 160 | 40 |
| BWC40-10H/HD | 400 | 40 |
| BWC40-12H/HD | 480 | 40 |
| BWC40-16H/HD | 640 | 40 |
| BWC40-18H/HD | 720 | 40 |
| BWC40-20H/HD | 800 | 40 |
| BWC80-14H/HD | 1120 | 80 |
| Connection Cable Type | Model | L (m) | Cable color |
|---|---|---|---|
| Emitter | CID4-3T | 3 | Black |
| CID4-5T | 5 | Black | |
| CID4-7T | 7 | Black | |
| CID4-10T | 10 | Black | |
| CID4-15T | 15 | Black | |
| Receiver | CID4-3R | 3 | Gray |
| CID4-5R | 5 | Gray | |
| CID4-7R | 7 | Gray | |
| CID4-10R | 10 | Gray | |
| CID4-15R | 15 | Gray |
| Operation Mode | Receiver | Operation indicator (green LED) | Transistor output |
|---|---|---|---|
| Light ON | Received light | ON | ON |
| Interrupted light | OFF | OFF | |
| Dark ON | Received light | ON | OFF |
| Interrupted light | OFF | ON |
| Diagnosis Item | Emitter operation indicator | Control output | Self-diagnosis output |
|---|---|---|---|
| Front screen contamination level 1 | Red, flashing at 1 sec interval | OFF | OFF |
| Front screen contamination level 2, covering optical axis | Red, flashing at 0.25 sec interval | ON | ON |
| Item | Emitter Indicator | Receiver Indicator | Control output |
|---|---|---|---|
| Power supply | Green | Green | - |
| Break of emitter | Red | - | - |
| Break of light emitting element | Yellow | OFF | OFF |
| Break of adjacent emitting element more than 2. | Yellow | OFF | OFF |
| Installation mode | Green | Green | - |
| Normal installation | OFF | OFF | - |
| Hysterisis section | Green | Yellow | - |
| Abnormal installation | Red | Yellow | - |
| Stable light ON area | Green | Green | ON |
| Unstable light ON area | Green | Yellow | ON |
| Unstable light OFF area | Red | Yellow | OFF |
| Stable light OFF area | Red | Red | OFF |
| Break of receiver | - | Red, flashing at 0.5 sec interval | OFF |
| Control output over current | - | - | OFF |
| Synchronous line malfunction | - | - | OFF |
| Emitter failure (time out) | - | - | OFF |
| Receiver failure (time out) | - | - | OFF |
2411220421_Autonics-BWC80-14H_C17412835.pdf