Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Industrial area sensor Autonics BW20-20 with synchronization type control and noise immunity features factory
<
quality Industrial area sensor Autonics BW20-20 with synchronization type control and noise immunity features factory
>
Specifications
Mfr. Part #:
BW20-20
Key Attributes
Model Number: BW20-20
Product Description

Product Overview

The D-44 BW Series Area Sensor is a high-performance through-beam type sensor designed for long-distance detection up to 7 meters. It offers a wide sensing height range and minimizes unsensing areas with its 20mm optical axis pitch. Featuring high-brightness LEDs for easy recognition from various angles and distances, this sensor includes essential functions like self-diagnosis, mutual interference prevention, and external diagnosis. Its robust IP65 protection structure makes it suitable for demanding industrial environments.

Product Attributes

  • Brand: Autonics (implied by context and page numbering)
  • Protection Structure: IP65 (IEC standard)
  • Material: Case: aluminum, Front cover, sensing part: acrylic
  • Light Source: Infrared LED (850nm modulated)
  • Approvals: (specific approval not detailed)

Technical Specifications

Model Sensing Method Sensing Distance Min. Sensing Target Optical Axis Pitch Number of Optical Axis Sensing Height Response Time Power Supply Current Consumption Operation Mode Control Output Protection Circuit Insulation Resistance Synchronization Type Self-Diagnosis Interference Protection Noise Immunity Dielectric Strength Vibration Shock Ambient Illumination Ambient Temperature Ambient Humidity Cable Weight (Unit Only)
BW20-(P) Through-beam type 0.1 to 7m Opaque material of min. 30mm 20mm 8 to 48 140 to 940mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Approx. 1.4kg
BW40-(P) Through-beam type 0.1 to 7m Opaque material of min. 50mm 40mm 4 to 24 120 to 920mm Max. 10ms 12-24VDC 10% (ripple P-P: max. 10%) Emitter: max. 120mA, Receiver: max. 120mA Light ON fixed NPN or PNP open collector output Load voltage: max. 30VDC Load current: max. 100mA Residual voltage - NPN: max. 1VDC, PNP: max. 2.5VDC Reverse polarity protection circuit, output short over current protection circuit Over 20M (at 500VDC megger) Timing method by synchronous line Emitter/Receiver monitoring, direct light monitoring, over current monitoring Interference protection by master/slave function 240V the square wave noise (pulse width 1) by the noise simulator 1,000VAC 50/60Hz for 1 min 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours 500m/s (approx. 50G) in each X, Y, Z direction for 3 times Max. 100,000lx (receiver illumination) -10 to 55, storage: -20 to 60 35 to 85%RH, storage: 35 to 85%RH 5mm, 4-wire, 300mm, M12 connector Approx. 1.4kg

Ordering Information

Item Optical axis pitch Number of optical axis Control output Model Example
No mark 20mm 04 to 48 NPN open collector output BW20-08(P)
P 40mm 4 to 48 PNP open collector output

Example: BW20-08P

Dimensions

(Diagrams for Emitter, Receiver, Bracket A, Bracket B are present in the source but cannot be rendered as HTML tables without specific data points. The following table provides key dimensional data derived from the diagrams.)

Model L (mm) A (mm) B (mm) Optical Axis Pitch (mm)
BW20-08(P) 160 20 40 20
BW40-04(P) 160 40 40 40
BW20-12(P) 240 20 40 20
BW40-06(P) 240 40 40 40
BW20-16(P) 320 20 40 20
BW40-08(P) 320 40 40 40
BW20-20(P) 400 20 40 20
BW40-10(P) 400 40 40 40
BW20-24(P) 480 20 40 20
BW40-12(P) 480 40 40 40
BW20-28(P) 560 20 40 20
BW40-14(P) 560 40 40 40
BW20-32(P) 640 20 40 20
BW40-16(P) 640 40 40 40
BW20-36(P) 720 20 40 20
BW40-18(P) 720 40 40 40
BW20-40(P) 800 20 40 20
BW40-20(P) 800 40 40 40
BW20-44(P) 880 20 40 20
BW40-22(P) 880 40 40 40
BW20-48(P) 960 20 40 20
BW40-24(P) 960 40 40 40

Features

  • Long sensing distance up to 7m.
  • Available in 22 types with optical axis pitches of 20/40mm and sensing heights from 120 to 940mm.
  • Minimizes unsensing area with 20mm optical axis pitch (BW20- models).
  • High-brightness LED on Emitter and Receiver for easy recognition from side, front, and long-distance.
  • Includes self-diagnosis, mutual interference prevention, and external diagnosis functions.
  • Protection structure: IP65 (IEC standard).

Functions & Operation

  • Operation Mode: Light ON fixed.
  • Self-Diagnosis: Emitter/Receiver monitoring, direct light monitoring, over current monitoring. Operation indicator displays status.
  • Interference Protection: Master/Slave function to prevent sensing errors when multiple sensors are used in parallel. Transmission direction should be opposite between 2 sets, and baffles should be installed.
  • External Diagnosis: When TEST input (black) of emitter is 0V, emitting stops, and the red LED of the emitter flashes. This allows external systems to check sensor operation.
  • Operation Indicator: Displays status for Power ON, MASTER operation, SLAVE operation, Test input, Break of emitter, Break of light emitting element, Break of receiver, Control output overcurrent, Synchronous line noise, Emitter failure (time out), Malfunction.

Wiring & Connections

(Details on Input/Output Circuits, Operation Indicator, and Connections are provided in the source text but are best represented visually or with specific diagrams not reproducible here. The following table summarizes connection points.)

Pin No. Cable Color (Emitter/Receiver) Emitter Function Receiver Function
1 Brown 12-24VDC 12-24VDC
2 White SYNC SYNC
3 Blue 0V 0V
4 Black TEST (M/S) OUT

Connecting Cables: Sold separately (e.g., CID4-3T, CID4-5T for Emitter; CID4-3R, CID4-5R for Receiver).

Troubleshooting

Cause Troubleshooting
Not operating Supply the rated power. Check wiring for incorrect connection or disconnection. Use within the rated sensing distance.
Not operating sometimes Remove dirt from the sensor cover. Check connector connections.
Control output is OFF even though there is no target object Use within the rated sensing distance. Remove any obstacle blocking the light path. Move away from strong electric wave or noise generators.
LED displays for break of light emitting element Break of light emitting element.
LED displays for failure of emitter Break of light emitting circuit.
LED displays for failure of receiver Break of light receiving element.
LED displays for synchronous line Synchronous line incorrect connection or disconnection. Break of synchronous circuit of emitter or receiver.
LED displays for control output over current Control output line is shorted. Overload. Check rated load capacity.
LED displays for emitter malfunction Emitter malfunction. Treat after checking the emitter display LED.

Proper Usage

  • Follow instructions in 'Proper Usage'.
  • Use 12-24VDC power supply that is insulated and limited voltage/current or Class 2, SELV.
  • Use the product 1 second after supplying power. If using separate power supplies, power the sensor first.
  • When using a switching mode power supply, ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
  • When connecting a DC relay or other inductive load, remove surge using diodes or varistors.
  • Wire as short as possible and keep away from high voltage lines or power lines to prevent surge and inductive noise.
  • Suitable for: Indoors (within rated environment conditions), Altitude max. 2,000m, Pollution degree 2, Installation category II.

2411220420_Autonics-BW20-20_C17675331.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max