quality Medical Equipment Oxygen Sensor Aosong AO-08 Electrochemical Sensor with Molded Body and Performance factory
<
quality Medical Equipment Oxygen Sensor Aosong AO-08 Electrochemical Sensor with Molded Body and Performance factory
>
Specifications
Mfr. Part #:
AO-08
Key Attributes
Model Number: AO-08
Product Description

Product Overview

The AO-08 Oxygen Sensor is an electrochemical sensor designed for measuring oxygen concentration in medical equipment. It features a molded body design, offering fast response times and a long service life. The sensor operates without an external power supply and comes factory-calibrated with temperature compensation for accurate and reliable performance. Its strong anti-interference capabilities make it suitable for various oxygen analysis applications, including oxygen concentrator control devices, medical ventilators, anesthesia equipment, and incubators.

Product Attributes

  • Brand: ASAIR (implied by copyright)
  • Origin: Guangzhou Aosong Electronics Co., Ltd.
  • Material: White ABS (housing)

Technical Specifications

Specification Value Notes
Model AO-08
Working Principle Partial pressure electrochemical
Output Voltage 9~13 mV (in air)
Measurement Range 0~100 %
Response Time (T90) <15 s
Accuracy 1 %
Linearity Full-range linear
Temperature Compensation <2% O2 equivalent (0~40 )
Load Resistance 10 k
Interface 3.5 mm TRS
Housing Material White ABS
Weight Approx. 40 grams
Operating Temperature Range 0~50
Operating Pressure Range 0.5~2.0 Bar
Operating Humidity Range 0~99% RH (non-condensing)
Long-term Drift (100% O2 environment) <5% (voltage decay/year) Output signal may drift below the lower limit over time.
Service Life 1.5106 % O2 hours (at 20 ) Example: At 20 , 50% O2, expected life is 1.5 106 / 50 = 0.3 105 hours.
Service Life 0.8106 % O2 hours (at 40 )
Shelf Life 13 months from date of shipment
Dimensions Refer to Figure 2 (Unit: mm, Tolerance: 0.15 mm)

Note on Technical Specifications: Parameters not specified in the table were measured under recommended circuit conditions, at 20 , 50% RH, 1013 mBar, and an oxygen flow rate of 100 mL/min. Technical specifications outline the sensor's performance within the first three months after leaving the factory.