Product Overview
The All Sensors DLVR Series Mini Digital Output Sensor leverages CoBeam2TM Technology to offer enhanced long-term stability and improved position sensitivity. Designed for integration into a wide range of process control and measurement systems, these calibrated and compensated sensors provide accurate, stable output over a broad temperature range. They are suitable for use with non-corrosive, non-ionic working fluids such as air and dry gases. The DLVR series offers low-voltage operation with options for very low-power modes, making them ideal for battery-powered applications. An optional protective parylene coating is available for enhanced moisture and harsh media protection.
Product Attributes
- Brand: All Sensors
- Technology: CoBeam2TM Technology
- Origin: Morgan Hill, CA
Technical Specifications
| Category | Specification | Details |
|---|---|---|
| General Specifications | Pressure Ranges | 0.5 to 60 inH2O |
| Supply Voltage | 3.3V Standard / 5V Option | |
| Interface | I2C Standard / SPI Option | |
| Performance Characteristics | Accuracy Over Temperature | Better than 1.0% Typical |
| Compensated Temperature Range | Commercial: 0C to 70C Industrial: -20C to 85C | |
| Operating Temperature Range | -25C to 85C | |
| Storage Temperature Range | -40C to 125C | |
| Humidity Limits (non-condensing) | 0 to 95% RH | |
| Maximum Ratings | Supply Voltage (Vs) | 6 Vdc |
| Common Mode Pressure | 10 psig | |
| Speed/Power Options | Fast (F), Noise Reduced (N), Low Power (L), Sleep (S) | |
| Interface Options | I2C, SPI (SPI only available with 8-lead packages) | |
| Coating Option | Parylene Coating (moisture/harsh media protection, not available for ranges below 10 inH2O) | |
| Digital Output | Resolution | 14-bit |
| No Missing Codes | 12-13 bit | |
| Applications | Medical Breathing, Environmental Controls, HVAC, Industrial Controls, Portable/Hand-Held Equipment | |
| Standard Pressure Ranges | Model | inH2O |
| DLVR-F50D | 0.5 | |
| DLVR-L01D | 1 | |
| DLVR-L02D | 2 | |
| DLVR-L05D | 5 | |
| DLVR-L10D | 10 | |
| DLVR-L20D | 20 | |
| DLVR-L30D | 30 | |
| DLVR-L60D | 60 | |
| Standard Gage Pressure Ranges | Model | inH2O |
| DLVR-L01G | 0 to 1 | |
| DLVR-L02G | 0 to 2 | |
| DLVR-L05G | 0 to 5 | |
| DLVR-L10G | 0 to 10 | |
| DLVR-L20G | 0 to 20 | |
| DLVR-L30G | 0 to 30 | |
| DLVR-L60G | 0 to 60 | |