DLHR Series Low Voltage Digital Pressure Sensors
Product Overview
The All Sensors DLHR Series Mini Digital Output Sensor leverages CoBeam2 Technology to minimize package stress, enhancing long-term stability and reducing position sensitivity. Its digital interface simplifies integration into process control and measurement systems, allowing direct connection to serial communication channels. Designed for battery-powered applications, these sensors feature a very low-power mode to conserve energy between readings. Calibrated and compensated, they deliver accurate and stable output across a wide temperature range. The DLHR series is suitable for use with non-corrosive, non-ionic working fluids such as air and dry gases. An optional parylene coating is available for enhanced moisture and harsh media protection.
Key Features & Applications
- 0.5 to 60 inH2O Pressure Ranges
- 1.68V to 3.6V Supply Voltage Range
- I2C or SPI Interface (Automatically Selected)
- Better than 0.25% Accuracy
- High Resolution 16/17/18 bit Output
- Applications: Medical Breathing, Environmental Controls, HVAC, Industrial Controls, Portable/Hand-Held Equipment
Technical Specifications
| Parameter | Min | Typ | Max | Units | Notes |
|---|---|---|---|---|---|
| Supply Voltage (Vs) | 1.75 | - | 3.60 | Vdc | Recommended |
| Supply Voltage (Vs) Absolute Maximum | - | - | 3.63 | Vdc | |
| Common Mode Pressure | - | - | 10 | psig | |
| Lead Temperature (soldering 2-4 sec.) | - | - | 270 | C | |
| Compensated Temperature Range (Commercial) | 0 | - | 70 | C | |
| Compensated Temperature Range (Industrial) | -20 | - | 85 | C | |
| Operating Temperature Range | -25 | - | 85 | C | |
| Storage Temperature Range | -40 | - | 125 | C | |
| Humidity Limits (non-condensing) | 0 | - | 95 | % RH | |
| Output Span (FSS) | - | 0.4 * 224 (LxxD, FxxD) / 0.8 * 224 (LxxG) | - | Dec Counts | 1 |
| Offset Output @ Zero Diff. Pressure (Osdig) | - | 0.5 * 224 (LxxD, FxxD) / 0.1 * 224 (LxxG) | - | Dec Counts | |
| Total Error Band | - | 0.35 (F50D) / 0.25 (L01x, L02x) / 0.20 (L05x) / 0.15 (L10x, L20x, L30x, L60x) | 1.50 (F50D) / 1.00 (L01x) / 0.75 (L02x, L05x, L10x, L20x, L30x, L60x) | %FSS | 2 |
| Span Temperature Shift | - | 0.5 (F50x, L01x, L02x) / 0.2 (L05x, L10x, L20x, L30x, L60x) | - | %FSS | 3 |
| Offset Temperature Shift | - | 0.5 (F50x, L01x, L02x) / 0.2 (L05x, L10x, L20x, L30x, L60x) | - | %FSS | 3 |
| Offset Warm-up Shift | - | 0.25 (F50x, L01x, L02x) / 0.15 (L05x, L10x, L20x, L30x, L60x) | - | %FSS | 4 |
| Offset Position Sensitivity (1g) | - | 0.10 (F50x, L01x, L02x) / 0.05 (L05x, L10x, L20x, L30x, L60x) | - | %FSS | |
| Offset Long Term Drift (One Year) | - | 0.25 (F50x, L01x, L02x) / 0.15 (L05x, L10x, L20x, L30x, L60x) | - | %FSS | |
| Linearity, Hysteresis Error | - | 0.25 (FxxD, LxxD) / 0.10 (LxxG) | - | %FSS | 6 |
| Pressure Digital Resolution | - | 15.7 (16-bit Option) / 16.7 (17-bit Option) / 17.7 (18-bit Option) | - | bit | No Missing Codes |
| Temperature Output Resolution | - | 16 | - | bit | |
| Supply Current Requirement (Active State) | - | 2 | 2.6 | mA | 5, 7, 8 |
| Supply Current Requirement (Idle State) | - | 100 | 250 | nA | 5, 7, 8 |
| Power On Delay | - | - | 2.5 | ms | 5 |
| Data Update Time (tDU) | - | - | - | ms | 5, 7 |
| I2C Address | - | 41 | - | decimal |
Standard Pressure Ranges
| Model | Nominal Span (inH2O) | Nominal Span (Pa) | Nominal Span (kPa) | Operating Range A (inH2O) | Operating Range A (Pa) | Operating Range A (kPa) | Proof Pressure (inH2O) | Burst Pressure (inH2O) | Counts |
|---|---|---|---|---|---|---|---|---|---|
| DLHR-F50D | 0.5 | 125 | 0.125 | 0.5 | 125 | 0.125 | 300 | 75 | 0.4 * 224 |
| DLHR-L01D | 1 | 250 | 0.25 | 1 | 250 | 0.25 | 300 | 75 | 0.4 * 224 |
| DLHR-L02D | 2 | 500 | 0.5 | 2 | 500 | 0.5 | 300 | 75 | 0.4 * 224 |
| DLHR-L05D | 5 | 1,250 | 1.25 | 5 | 1,250 | 1.25 | 300 | 75 | 0.4 * 224 |
| DLHR-L10D | 10 | 2,500 | 2.5 | 10 | 2,500 | 2.5 | 300 | 75 | 0.4 * 224 |
| DLHR-L20D | 20 | 5,000 | 5 | 20 | 5,000 | 5 | 500 | 125 | 0.4 * 224 |
| DLHR-L30D | 30 | 7,500 | 7.5 | 30 | 7,500 | 7.5 | 500 | 125 | 0.4 * 224 |
| DLHR-L60D | 60 | 15,000 | 15 | 60 | 15,000 | 15 | 800 | 200 | 0.4 * 224 |
| DLHR-L01G | 0 to 1 | 250 | 0.25 | 0 to 1 | 250 | 0.25 | 300 | 75 | 0.8 * 224 |
| DLHR-L02G | 0 to 2 | 500 | 0.5 | 0 to 2 | 500 | 0.5 | 300 | 75 | 0.8 * 224 |
| DLHR-L05G | 0 to 5 | 1,250 | 1.25 | 0 to 5 | 1,250 | 1.25 | 300 | 75 | 0.8 * 224 |
| DLHR-L10G | 0 to 10 | 2,500 | 2.5 | 0 to 10 | 2,500 | 2.5 | 300 | 75 | 0.8 * 224 |
| DLHR-L20G | 0 to 20 | 5,000 | 5 | 0 to 20 | 5,000 | 5 | 500 | 125 | 0.8 * 224 |
| DLHR-L30G | 0 to 30 | 7,500 | 7.5 | 0 to 30 | 7,500 | 7.5 | 500 | 125 | 0.8 * 224 |
| DLHR-L60G | 0 to 60 | 15,000 | 15 | 0 to 60 | 15,000 | 15 | 800 | 200 | 0.8 * 224 |
Device Options
| Option | Description |
|---|---|
| Parylene Coating | Provides a moisture barrier and protection from some harsh media. Not available for pressure ranges below 10 inH2O. |
| Output Resolution | Available in 16, 17, or 18 bits. Higher resolution results in slower update times. |
Product Attributes
- Brand: All Sensors
- Series: DLHR
- Technology: CoBeam2 Technology
- Interface: I2C or SPI (Auto-selected)
- Working Fluids: Non-corrosive, non-ionic (e.g., air, dry gases)
2411220634_Amphenol-DLHR-F50D-E1BD-C-NAV8_C6540178.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible