Specifications
Mfr. Part #:
T8100-E-D-GN-R
Key Attributes
Model Number: T8100-E-D-GN-R
Product Description

Product Overview

Telaire Ventostat 8000 series wall mount transmitters are designed for monitoring CO2, humidity, and temperature in occupied building HVAC applications. These devices are crucial for demand-controlled ventilation, preventing energy waste from over-ventilation while maintaining indoor air quality. They are ideal for controlling specific areas like conference rooms, classrooms, and meeting halls. The series features a patented Absorption Infrared Gas sensing engine for high accuracy and a patented ABC Logic self-calibration system that eliminates the need for manual calibration in most applications, offering a lifetime CO2 calibration guarantee for T8100 and T8300 models. The two-piece design allows for easy unit replacement without rewiring, and a modern enclosure with optional customized branding is available.

Product Attributes

  • Brand: Telaire (Amphenol Advanced Sensors)
  • Series: Ventostat 8000
  • Sensing Technology: Patented Absorption Infrared Gas sensing engine (NDIR)
  • Calibration System: Patented ABC Logic self-calibration (T8100, T8300)
  • Calibration Guarantee: Lifetime for T8100/T8300 (ABC Logic enabled), 2 years for T8200
  • Enclosure: Modern, two-piece design, customized branding available, smaller enclosure versions (81.4 mm x 86.4 mm), splash resistant (T1505), outside air (T1552), aspiration box for duct mounting (T1508)
  • Certifications: CE and RoHS compliant
  • Output Options: Dual simultaneous analog outputs (0-10 V & 4-20mA) for CO2, BACnet (MS/TP, RS485)
  • Field Serviceability: Field-replaceable RH sensor tip module
  • Filter: Gas permeable, water resistant CO2 diffusion filter
  • Security: Locking screw for tamper resistance
  • Intended Use: Occupied building HVAC applications
  • Not Designed For: Safety critical functions

Technical Specifications

Specification Details
CO2 Measurement Range T8100/T8200/T8300: 0 to 2000 ppm
T8100/T8200/T8300 - 5P models: 0 to 5000 ppm
T8200 (10P models): 0 to 10,000 ppm
T8200 (20P models): 0 to 20,000 ppm
CO2 Accuracy 30ppm or 3% of reading, whichever is higher*
Power Supply 18-30 VAC RMS, 50/60 Hz, or 10.8 to 42 VDC, polarity protected
Power Consumption Typical 0.7 W at 24V AC RMS
Temperature Dependence 0.2% FS per C (0.11% per F)
Stability T8100/T8300 (Single Channel): <2% of FS over life (15 years)
T8200 (Dual Channel): <5% of FS or <10% reading annual over life (10 years)
Pressure Dependence 0.135% of reading per mm Hg
Warranty 24 months on mechanical defects
Signal Update Every 5 seconds
CO2 Warm-up Time < 2 minutes (operational), 10 minutes (maximum accuracy)
Operating Conditions 32F to 122F (0C to 50C), 0 to 95% RH (non-condensing)
Storage Conditions -40F to 158F (-40C to 70C)
Flammability Classification UL94 5VA
Thermistor Type NTC 10 K W (Passive, not BACnet version)
Thermistor Accuracy 1C (15 to 35C)
RH Sensing Element Capacitive polymer sensor
RH Range 0% to 99% RH (non-condensing)
RH Accuracy (25C) 2.5% RH (20 to 80% RH), 3.5% RH (<20% and >80% RH)
Active Temperature Accuracy 0.8C @ 22C
Active Temperature Range 32F to 122F (0C to 50C)
BACnet Baud Rates 38400 or 9600
T8300 Pitot Tube Kit For duct measurement of CO2
T1505 Splash Resistant Enclosure Protects against dripping/sprayed water; slows response time to ~30 min for 90% change
T1552 Outside Air Enclosure Weatherproof with temperature control and heaters; operates down to -20F (-29C); slows response time to ~30 min for 90% change
T1508 Aspiration Box For in-duct sampling (>400 fpm); accommodates 8100/8200 series; probe: 1-inch diameter, 8-inch length
UIP Software (T2090) Altitude adjustment, analog output adjustment, calibration, ABC Logic control, temp display units, graphing/logging (H versions)

*CO2 accuracy statement excludes standard gas used for calibration (accuracy of 2%) and potential digital to analog error (up to 1%).